1859 matches found
Excluded VM Disk is Still Snapshotted
Challenge Disks of a VM being backed up by Veeam Backup & Replication are snapshotted even though they were excluded from the backup job. Solution Per the Veeam Backup & Replication user guide: When you exclude disks from a backup, they will only be removed from the backup operation. It is...
Installing Microsoft SQL Management Studio
Challenge Sometimes database edits are required to correct issues with Veeam ONE or Veeam Backup & Replication software. Cause Microsoft SQL Management Studio can be used to troubleshoot Veeam databases or install database hotfixes. Solution The latest release of SQL Server Management Studio is...
Error "A hard drive is missing" when performing file restore of VM
Challenge The version of Veeam Backup & Replication you are on likely does not support the Windows drive type. Cause In older versions of Veeam Backup & Replication, we were unable to perform File Level Recoveries on drives with the GPT type or marked as Dynamic with a spanned volumes. If you are...
How to Manually Seed a Replica
Purpose Under certain circumstances, the seeding function used by a Replication job may not function correctly. If this occurs, an alternate seeding method is to manually pre-create the replica from a backup and then use the mapping function of the Replication job to map to that restored VM...
No network data available for ESX(i) hosts
Challenge SCOM shows the following alert: VP510 No metrics obtained for ESX hosts, failed to process performance or configuration data for hosts Under SCOM Monitoring - Veeam for Vmware- vSphere Host- Performance views, performance counters for hosts actually exist and show all data except for th...
Attempt to launch Veeam Backup and Replication fails
Challenge An attempt to launch Veeam Backup & Replication fails with the message that Veeam Backup and Replication service is not running: The service can actually be seen as running: The following entries can be seen in VeeamShell.log: Timestamp Info ------- Started new session of Veeam Shell...
Veeam ONE Fails to Collect Performance Data from a Hyper-V Host
Challenge Veeam ONE fails to collect performance data from one or multiple Hyper-V hosts despite being able to collect infrastructure and topology data. This issue may occur with or without an alarm being triggered. When an alarm is triggered, it will display the message: Performance data...
Veeam VMware Collector service stops
Challenge Veeam VMware Collector service stops running regularly, the logs show that a stop call has been initiated. The vmspi.log contains the following entry: NOTFY Signal: shutting down: 0-LS LS Shutdown invoked. There are also "Info" events ID 7036 in the Windows System Event log with the...
Error “Please install Microsoft Visual C++ 2010 SP1 Redistributable Package and try again.” when attempting to install Veeam Backup & Replication Cloud Edition
Error “Please install Microsoft Visual C++ 2010 SP1 Redistributable Package and try again.” when attempting to install Veeam Backup & Replication Cloud Edition...
Release notes for Veeam MP Integration Management Pack update
Challenge Maintenance mode synchronization in System Center 2012 Operations Manager SP1 Importing the updated Veeam Integration MP will resolve the known issue related to maintenance mode synchronization in System Center 2012 Operations Manager SP1. When a vSphere host enters the maintenance mode...
Patch 3 Release Notes for Veeam Backup & Replication 6.5
Challenge These are the issues resolved by the Patch 3 for Veeam Backup version 6.5.0.106 / 6.5.0.109 / 6.5.0.128. This patch is cumulative and contains fixes fromPatch 1. Cause Please confirm you are running version 6.5.0.106/6.5.0.109/6.5.0.128 prior to applying this patch. You can check this...
Failed to register replica VM
Challenge When using vCenter 4.0 unable to perform replication if target host doesn't have the same vNetwork as source. Replica network re-mapping doesn't work either. Replication job fails to register replica VM with the following error: Failed to register VM, configFile 'Datastore01...
Number of Cores Incorrectly Detected - Server 2003/XP
Challenge When adding a Server 2003 or Windows XP machine to Veeam, the true number of cores is not detected properly. Instead Veeam Backup & Replication only detects the number of Sockets. Example: A virtual machine with Server 2003, having a configuration of 2 Sockets and 4 Cores, is added to...
Scheduled automatic dashboard delivery fails
Challenge In certaing scenarios, scheduled dashboard delivery in Veeam ONE Reporter fails and reports the 'Dashboard Capturing Failed' error in the reporting task session log. Cause This issue is usually related to the configured permissions of the Veeam ONE Service account, which makes the...
Moving custom attributes through import/export of CSV file
Purpose To export custom attributes from one installation of Business View to another, follow these steps: 1. Click Configuration in the top right corner of the screen and navigate to the Import/Export pane. 2. This step is not mandatory If you want to pre-designate which custom attributes Busine...
High guest OS resource utilization
Challenge Performance metrics within a Virtual Machine's Guest OS are different higher or lower than the same metrics reported by Veeam ONE. Cause The process used by vSphere to allocate and distribute system resources differs from the methods used by Windows and other operating systems for a...
Tips for DAG Exchange Backup and Replication in vSphere
Challenge During the snapshot creation or commit phase of a Veeam Backup or Replication job using vSphere, a primary node in a DAG cluster may lose the heartbeat long enough to cause a failover to the secondary node. Cause This problem is caused by the lack of connectivity in VMware vSphere durin...
Deduplication Appliance Best Practices
Purpose This article provides links to vendor-provided best practices documents and vendor-specific configuration advice found in the Veeam Backup & Replication User Guide. It also offers general recommendations for configuring Veeam Backup & Replication jobs and repositories when utilizing...
Error “Unexpected VHD Feature Mask ‘6’” on Hyper-V backup or replication job
Challenge The feature mask 6 error is Hyper-V specific. This KB covers that error and how to resolve it. Cause Feature mask 6 errors most often occur when a Hyper-V VM was a Physical to Virtual conversion using third party software. The issue is that some third party converter software creates th...
"Failed to lock file" NFS Repository with Datadomain Storage
Challenge A task for attempting to send backups to a Datadomain NFS share that is either added directly as an NFS Repository or mounted to a Linux intermediary server as a Linux repository fails with the error: Processing Error: Input/output error Failed to lock file /mnt/path/to/backup.vbk. Fail...
Slow backup perfomance in HOTADD (virtual appliance) mode
Challenge In some cases, depending on infrastructure setup and iSCSI storage, you can experience an issue when HOTADD mode performs slower than NBDnetwork mode. Cause Some iSCSI storage arrays from different array vendors do not behave appropriately during periods of network congestion. This...
Event pre-filtering causes high vCenter Database load
Challenge The vCenter Database utilizes most of the available CPU, impacting vCenter Server performance. Stopping nworks Collectors brings the CPU usage back to normal. The nworks vmspi log shows the following errors: VCEVT+ VC250 retrieveEvents: createFilter failed, System.Net.WebException: The...
Not getting hardware sensor alerts in a timely manner
Challenge You do not receive information about specific alerts regarding host hardware sensors quick enough for your environment, both in the Veeam ONE Monitor GUI and e-mails. For example, a host goes offline and you do not get any alerts for 20 minutes. Or there is another delayed alerting...
How to Forcibly Stop Stuck Jobs
Challenge This KB documents the process for forcibly terminating all jobs for a given Veeam Backup & Replication server. The steps outlined in this KB will terminate all active jobs and tasks. Notes: Please understand that some jobs may take some time to stop. Please allow up to 60 minutes for jo...
A required privilege is not held by the client
Domain Controller configuration fails with an error: A required privilege is not held by the client...
Veeam Backup & Replication - HP San Setup Guide
Challenge Veeam Explorer for SAN Snapshots lets you perform Veeam restores of entire VMs or individual items directly from HP StoreVirtual VSA and LeftHand snapshots. And like Explorer for Exchange, it's included in all editions of Veeam Backup & Replication. Cause This is a how-to guide on...
The specified network name is no longer available
Challenge When accessing backup files on a CIFS SMB repository, Veeam Backup & Replication reports either of the following errors: The specified network name is no longer available. code 59, 0x8007003B An unexpected network error occurred. code 64, 0x80070040 Veeam Backup & Replication uses SMB...
Configuring Veeam Backup Cloud Edition with HP Cloud
Challenge Specifying a container in HP Cloud account settings results in the following error: Incorrect HTTP method used in the request 26301 Fault Name: IncorrectHTTPMethod Error Type: MethodValidationFailure Description: Incorrect HTTP method used in the request Service: publiccsservices...
How to Relocate Veeam Backup & Replication Backup Files
Purpose This article provides information about relocating the backup data managed by Veeam Backup & Replication between repositories, including between simple Backup Repositories, Scale-Out Backup Repositories, and Object Storage Repositories. Solution Summary This article documents two methods ...
Event ID 10378 in the Operations Manager Event Log on Collector
Challenge Operations Manager Event Log on the Collector server contains the following warning: ID 10378 Module was unable to convert WMI setting .\timestamp Event IDs 1103 and 4506 may also be observed. Cause The root cause is currently investigated by Microsoft. This article will be updated afte...
Intermittent vCenter disconnections in Veeam ONE Monitor
Challenge vCenter periodically disconnects from Veeam ONE Moniotor. This causes intermittent alerts that get resolved automatically in several minutes when a connection is restored. Cause This behavior is caused by vCenter Update Manager. When checking for updates Update Manager might freeze...
All Veeam services stop at the same time everyday
Challenge Veeam services stop at the same time every night. Cause Microsoft SCCM has a Health Agent Task scheduled to run over night. The task does not support WMI 3.0. WMI 3.0 is incorporated in Veeam Backup & Replication as a dependency. When the Health Agent clears the WMI repository, it kills...
Limitation on number of EDBs mounted in Veeam Explorer for Exchange
Challenge The number of databases that can be mounted in Veeam Explorer for Exchange at a time is currently limited to 15. Solution If the limit has been reached, you will not be able to mount new databases. You can manually remove unnecessary mailbox stores in Veeam Explorer for Exchange and the...
Patch 1 Release Notes for Veeam Backup & Replication 6.5
Challenge These are the issues resolved by the Patch 1 for Veeam Backup version 6.5.0.109. All patches are cumulative so each below fix is contained in this patch. Cause Please confirm you are running version 6.5.0.106 or 6.5.0.109 prior to applying this patch. You can check this under Help | Abo...
Dashboards fail with errors in Microsoft System Center Operations Manager 2012
Challenge The Resource Pool dashboard, Virtual Applications dashboard, Resource Pool State and Virtual Application State views fail with the following error when accessed in Microsoft System Center Operations Manager 2012: An item with the same key has already been added Cause This is a known...
Patch 1 Release Notes for Veeam ONE 6.5.0.676
Challenge Patch 1 for Veeam ONE 6.5.0.676 resolves a number of issues described in this article. All patches are cumulative, which means that this patch includes allfixes listed below. Cause Prior to applying this patch, make sure you are running Veeam ONE version 6.5.0.676. You can check this...
Buttons Disappear on Chinese localized servers in Veeam Backup & Replication object properties
Challenge On Chinese localized servers, buttons will not appear on standard DPI, but will show up instead once the DPI is increased to large. Solution To resolve, use Medium DPI 120 - 125% as opposed to Normal Small DPI 96 - 100%, or change the registry font settings. Note that editing the regist...
VSS Errors Related to the 'NTDS' VSS Writer
Challenge This article discusses an error that occurs due to VSS and Veeam's Guest Processing technique for Domain Controllers. It is relevant to all backup jobs for both virtual and physical Domain Controllers. A job processing a Domain Controller with Application-Aware Processing fails with one...
Unable to Mount VPower NFS Specified Key Name or Identifier Already Exists
Challenge During a Veeam vPower NFS-based operation SureBackup, Instant Recovery, Instant Disk Recovery, or Other-OS FLR, the following errors may occur: Unable to mount vPower NFS volume :/VeeamBackup. Fault "AlreadyExistsFault", Error The specified key, name, or identifier already exists. Unabl...
Monitoring vSphere 5.1 and 5.5 with Veeam MP/SPI 5.7
Challenge If you connect to vCenter Server 5.1 or 5.5, Veeam MP/SPI 5.7 will not collect some data, including hardware sensor metrics and vCenter-specific events and properties that were introduced by VMware since VMware vSphere 4.0. vCenter events and properties that were introduced before VMwar...
Installing package Transport Error: Error 1935.An error occurred during the installation of assembly component
Challenge When Veeam Backup & Replication attempts to install the Veeam Transport package VeeamTransport.msiC:\Program Files\Veeam\Backup and Replication\Backup\Packages\VeeamTransport.msi the package fails to install, and the following errors may be displayed in the UI: Installing package...
Veeam Explorer for Microsoft Exchange: Could not establish trust relationship for the SSL/TLS secure channel
Challenge When restoring items with Veeam Explorer for Microsoft Exchange or sending them as attachments, the following error occurs: The request failed. The underlying connection was closed: could not establish trust relationship for the SSL/TLS secure channel Cause There are two possible causes...
Upgrade to version 6.5 fails with the "Unable to connect to SQL Server" error
Challenge When upgrading to Veeam Backup & Replication version 6.5 you receive the error: "Unable to connect to SQL Server servername=:Login failed for user", even though the dbowner account is used. You also experience one of the following symptoms: You receive repeated logon windows You receive...
Jobs missing from Enterprise Manager 6.5
Jobs disappeared from Enterprise Manager after upgrade to version 6.5.0.106...
VM Loses Connection During Snapshot Removal
Challenge During the snapshot removal step of a Veeam Backup & Replication task, the source vSphere VM loses connectivity temporarily. Cause Veeam does not remove the snapshot itself; Veeam sends an API call to the vSphere environment to have the action performed. The snapshot removal process...
The user has not been granted the requested logon type on this computer
Challenge Although the nWorks service account has local administrator rights and is a member of the nWorks Enterprise Manager Accounts local group, nWorks Collector and Enterprise Manager cannot be installed, because the installer does not accept the specified service account. The following error...
"VM MAC address conflict" and "VM instance UUID conflict" alarms
Challenge During replication jobs, Veeam ONE triggers the VM MAC address conflict and VM instance UUID conflict alarms. Cause These alarms occur when Veeam ONE detects the following events within the vSphere Environment: VmStaticMacConflictEvent VmMacConflictEvent VmInstanceUuidConflictEvent Thes...
Cannot open database requested by login. The login failed
Challenge When you try to access Veeam ONE Web UI, the following error occurs: Cannot open database requested by login. The login failed. Cause Veeam ONE Web UI configuration is missing information on the account used for SQL authentication. Solution To modify configuration settings, follow the...
Time difference between Veeam Monitor server and ESX host is too large.
Challenge When attempting to add a vCenter Server or a standalone host with a different time zone, the operation may fail with the error: Failed to connect to "". Time difference between Veeam Monitor server and ESX host is too large. Make sure that NTP is enabled on ESX host and try again. Cause...
VSS Timeout when backing up Exchange VM
Challenge The backup of an Exchange server VM fails with: Unfreeze error:Backup job failed Cannot create shadow copy of the volumes containing writer’s data A VSS critical writer has failed. Writer name: Microsoft Exchange Writer. Class ID: 76fe1ac4-15f7-4bcd-987e-8e1acb462fb7. Instance ID:...