Siemens SCALANCE, SIMATIC, RUGGEDCOM, and SINAMICS Products (Update A)
CVSS v3 6.8 Vendor: Siemens Equipment: SCALANCE, SIMATIC, RUGGEDCOM, and SINAMICS Products Vulnerabilities: Security Features UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-17-318-01 Siemens SCALANCE, SIMATIC, RUGGEDCOM, and SINAMICS Products that was...
Cogent DataHub Elevation of Privilege Vulnerability
OVERVIEW Steven Seeley of Source Incite has identified a privilege elevation vulnerability in the Cogent DataHub application produced by Cogent Real-Time Systems, Inc. Cogent has produced a new version to mitigate this vulnerability. Steven Seeley has tested the new version to validate that it...
Schneider Electric IONXXXX Series Power Meter Vulnerabilities
OVERVIEW This advisory is a follow-up to the alert titled ICS-ALERT-16-256-02 Schneider Electric ION Power Meter CSRF Vulnerability that was published September 12, 2016, on the NCCIC/ICS-CERT web site. Independent researcher Karn Ganeshen has identified a cross-site request forgery CSRF and no...
Moxa OnCell Vulnerabilities (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-236-01 Moxa OnCell Vulnerabilities that was published August 23, 2016, on the NCCIC/ICS-CERT web site. Independent researcher Maxim Rupp has identified several vulnerabilities in Moxa’s OnCell products. Moxa has...
Moxa SoftCMS Vulnerabilities
OVERVIEW Zhou Yu working with Trend Micro’s Zero Day Initiative and Gu Ziqiang from Huawei Weiran Labs have identified vulnerabilities in Moxa’s SoftCMS Webserver Application. Moxa has produced an update to mitigate these vulnerabilities. Both researchers have tested the update to validate that i...
Siemens Automation License Manager Vulnerabilities
OVERVIEW Siemens has identified vulnerabilities in Siemen’s Automation License Manager ALM. These vulnerabilities were reported directly to Siemens by Sergey Temnikov and Vladimir Dashchenko from Critical Infrastructure Defence Team, Kaspersky Lab. Siemens has produced a new version to mitigate...
ABB PCM600 Vulnerabilities
OVERVIEW ABB has identified one use of password hash with insufficient computational effort and three insufficiently protected credentials vulnerabilities in ABB’s PCM600. These vulnerabilities were reported directly to ABB by Ilya Karpov from Positive Technologies. ABB has produced a new version...
7-Technologies IGSS Buffer Overflow
Overview Security researcher Celil Unuver SignalSEC LLCSignalSEC LLC, www.signalsec.com, website last accessed December 21, 2011. has identified a buffer overflow vulnerability in the 7-Technologies 7T Interactive Graphical SCADA System IGSS product. Successful exploitation of this vulnerability...
Siemens Solid Edge
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Rockwell Automation 5015-AENFTXT (Update A)
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : 5015-AENFTXT Vulnerability : Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to crash the...
Rockwell Automation Arena Simulation
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION : low attack complexity Vendor : Rockwell Automation Equipment : Arena Simulation Software Vulnerabilities : Out-of-bounds Write, Heap-based Buffer Overflow, Improper Restriction of Operations within the Bounds of a Memory Buffer, Use After...
Siemens Mendix Studio Pro
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Schneider Electric EcoStruxure Operator Terminal Expert
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity/public exploits are available Vendor: Schneider Electric Equipment: EcoStruxure Operator Terminal Expert VXDZ Vulnerability: Improper Control of Generation of Code 'Code Injection' 2. RISK EVALUATION Successful exploitation of this...
#StopRansomware: Vice Society
Summary Actions to take today to mitigate cyber threats from ransomware: • Prioritize and remediate known exploited vulnerabilities. • Train users to recognize and report phishing attempts. • Enable and enforce multifactor authentication. Note: This joint Cybersecurity Advisory CSA is part of an...
Delta Electronics ASDA-Soft
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: ASDA-Soft Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow arbitrary code execution. 3. TECHNICAL DETAILS...
Siemens COMOS Web (Update A)
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: COMOS Vulnerabilities: Basic XSS, Relative Path Traversal, SQL Injection, Cross-site Request Forgery 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update...
Siemens NX
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: NX Vulnerabilities: Use After Free, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead to an access violation and to arbitrary code execution on the target...
Mitsubishi Electric MELSEC iQ-R Series
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION : Exploitable remotely/low attack complexity Vendor : Mitsubishi Electric Corporation Equipment : MELSEC iQ-R Series CPU Module Vulnerability : Cleartext Transmission of Sensitive Information 2. RISK EVALUATION Successful exploitation of this...
WAGO M&M Software fdtCONTAINER (Update C)
1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Low skill level to exploit Vendor: M&M Software GmbH, a subsidiary of WAGO Kontakttechnik Equipment: fdtCONTAINER Vulnerability: Deserialization of Untrusted Data 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled...
Siemens Solid Edge
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Siemens Equipment: Solid Edge Vulnerabilities: Out-of-bounds Write, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow arbitrary code execution on an affected...
Moxa EDR-G902 and EDR-G903 Series Routers
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Moxa Equipment: EDR-G902 and EDR-G903 Series Routers Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the device being...
Moxa ioLogik 2542-HSPA Series Controllers and IOs, and IOxpress Configuration Utility
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Moxa Equipment: ioLogik 2542-HSPA Series Controllers and IOs, and IOxpress Configuration Utility Vulnerabilities: Cleartext Storage of Sensitive Information, Cleartext Transmission of Sensitive...
Siemens SINAMICS (Update C)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINAMICS Vulnerability: Uncontrolled Resource Consumption 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update ICSA-19-227-04 Siemens SINAMICS Update...
Siemens SIMATIC S7-1500 CPU
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC S7-1500 CPU Vulnerabilities: Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow a denial of service condition of...
Advantech WebAccess HMI Designer
1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION : Exploitable remotely/low skill level to exploit. Vendor : Advantech Equipment : Advantech WebAccess HMI Designer Vulnerabilities : Heap-based Buffer Overflow, Double Free, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these...
Yokogawa CENTUM and Exaopc
1. EXECUTIVE SUMMARY CVSS v3 6.5 Vendor : Yokogawa Equipment : CENTUM series and Exaopc Vulnerability : Permissions, Privileges, and Access Controls 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local attacker to generate false system or process alarms, or block...
Siemens SiPass integrated
CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SiPass integrated Vulnerabilities: Improper Authentication, Improper Privilege Management, Channel Accessible by Non-Endpoint, Storing Passwords in a Recoverable Format AFFECTED PRODUCTS Siemens...
Siemens OZW672 and OZW772
CVSS v3 7.4 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: OZW672 and OZW772 Vulnerabilities: Missing Authentication AFFECTED PRODUCTS Siemens reports that the vulnerability affects the following OZW672 and OZW772 devices for monitoring building controller...
ICSMA-17-009-01A_St. Jude Merlin@home Transmitter Vulnerability (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSMA-17-009-01 St. Jude Merlin@home Transmitter Vulnerability that was published January 9, 2017, on the NCCIC/ICS-CERT web site. --------- Begin Update A Part 1 of 5 -------- MedSec Holdings has identified a channel...
Siemens SIMATIC S7-1200 CPU Protection Mechanism Failure
OVERVIEW Siemens has identified a protection mechanism failure vulnerability in old firmware versions of SIMATIC S7-1200. Maik Brüggemann and Ralf Spenneberg from Open Source Training reported this issue directly to Siemens. Siemens provides SIMATIC S7-1200 CPU product, release V4.0 or newer, to...
Adcon Telemetry A850 Telemetry Gateway Base Station Vulnerabilities
OVERVIEW Independent researcher Aditya K. Sood has identified a cross-site scripting vulnerability in Adcon Telemetry’s A850 Telemetry Gateway Base Station. Adcon Telemetry has produced a new firmware version to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED...
Siemens SIMATIC WinCC, PCS 7, and WinCC Runtime Professional Vulnerabilities (Update C)
OVERVIEW This updated advisory is a follow-up to the advisory update titled ICSA-16-208-01B Siemens SIMATIC WinCC, PCS 7, and WinCC Runtime Professional Vulnerabilities that was published October 4, 2016, on the NCCIC/ICS-CERT web site. Siemens has identified two vulnerabilities in SIMATIC WinCC,...
Siemens SIMATIC NET PC-Software Denial-of-Service Vulnerability
OVERVIEW Siemens has identified a denial-of-service vulnerability in SIMATIC NET PC-Software. Vladimir Dashchenko and Sergey Temnikov from Kaspersky Labs reported this issue directly to Siemens. Siemens has produced a new version to mitigate this vulnerability. This vulnerability could be exploit...
Siemens SIMATIC WinCC Sm@rtClient iOS Application Authentication Vulnerabilities
OVERVIEW Siemens has identified authentication vulnerabilities in the SIMATIC WinCC Sm@rt Client application. These vulnerabilities were reported directly to Siemens by Kim Schlyter, Seyton Bradford, and Richard Warren from FortConsult NCC Group. Siemens has produced an update that mitigates thes...
Advantech WebAccess Vulnerabilities
OVERVIEW This advisory is a follow-up to the original advisory titled “ICSA-14-079-03P Advantech WebAccess Vulnerabilities” that was posted to the US-CERT secure Portal library March 20, 2014. Researchers working with HP’s Zero Day Initiative ZDI, Andrea Micalizzi, aka rgod, Tom Gallagher, and an...
Schneider Electric Wonderware Vulnerabilities
OVERVIEW Timur Yunusov, Ilya Karpov, Sergey Gordeychik, Alexey Osipov, and Dmitry Serebryannikov of the Positive Technologies Research Team have identified four vulnerabilities in the Schneider Electric Wonderware Information Server WIS. Schneider Electric has produced an update that mitigates...
Honeywell HMIWeb Browser Buffer Overflow Vulnerability
OVERVIEW This advisory was originally posted on the the US-CERT secure portal library titled ICSA-12-150-01P Honeywell HMIWeb Browser Buffer Overflow Vulnerability to allow customers time to download the vendor patch prior to full public disclosure. ICS-CERT received a report from Honeywell and t...
Siemens SINEC Traffic Analyzer
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Delta Electronics InfraSuite Device Master
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Delta Electronics Equipment : InfraSuite Device Master Vulnerability : Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow remote...
Siemens RUGGEDCOM APE1808
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens Simcenter Femap
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Mitsubishi Electric FA Engineering Software Products (Update D)
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Mitsubishi Electric Equipment : EZSocket, FR Configurator2, GT Designer3 Version1GOT1000, GT Designer3 Version1GOT2000, GX Works2, GX Works3, MELSOFT Navigator, MT Works2, MX Component, MX...
Hitron Systems Security Camera DVR
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION : Exploitable remotely/low attack complexity/public exploits are available/known public exploitation Vendor : Hitron Systems Equipment : DVR Vulnerability : Improper Input Validation 2. RISK EVALUATION Successful exploitation of these...
Siemans WIBU Systems CodeMeter
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens RUGGEDCOM CROSSBOW
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services ...
Hitachi Energy Relion 670, 650 and SAM600-IO Series
1. EXECUTIVE SUMMARY CVSS v3 4.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: Relion 670, 650, and SAM600-IO Series Vulnerability: Insufficient Verification of Data Authenticity 2. RISK EVALUATION Successful exploitation of this vulnerability could cause...
Hitachi Energy MicroSCADA Pro/X SYS600 Products (Update A)
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION : Low attack complexity Vendor : Hitachi Energy Equipment : MicroSCADA X SYS600, MicroSCADA Pro Vulnerability : Improper Use of Validation Framework 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized...
Hitachi Energy Lumada Asset Performance Management Prognostic Model Executor Service
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/public exploits are available Vendor: Hitachi Energy Equipment: Lumada Asset Performance Manager APM Vulnerabilities: Allocation of Resources Without Limits or Throttling, Code injection 2. RISK EVALUATION Successful exploitation of...
Johnson Controls Metasys ADS, ADX, OAS
1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Johnson Controls, Inc Equipment: Metasys ADS, ADX, OAS with MUI Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow...
General Electric Renewable Energy MDS Radios
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: General Electric Renewable Energy Equipment: MDS iNET/iNET II/SD/TD220/TD220MAX Radios Vulnerabilities: I mproper Input Validation, Hidden Functionality, Inadequate Encryption Strength, Uncontrolled...