Lucene search
+L
ICSMost viewed

4473 matches found

ICS
ICS
•added 2020/10/13 12:00 a.m.•88 views

Fieldcomm Group HART-IP and hipserver

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Fieldcomm Group Equipment: HARP-IP Developer kit, hipserver Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the device being...

10CVSS10AI score0.01548EPSS
SaveExploits0References5
ICS
ICS
•added 2020/06/09 12:00 a.m.•88 views

Siemens SIMATIC, SINAMICS (Update C)

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SIMATIC, SINAMICS Vulnerabilities: Uncontrolled Search Path Element, Heap-based Buffer Overflow 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-20-161-05...

7.8CVSS8.3AI score0.00452EPSS
SaveExploits0References11
ICS
ICS
•added 2020/05/21 12:00 a.m.•88 views

Johnson Controls Software House C-CURE 9000 and American Dynamics victor VMS

1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Sensormatic Electronics, LLC, a subsidiary of Johnson Controls Equipment: Software House C•CURE 9000 and American Dynamics victor Video Management System Vulnerability: Cleartext Storage of...

9.9CVSS7.7AI score0.0099EPSS
SaveExploits0References5
ICS
ICS
•added 2020/02/11 12:00 a.m.•88 views

Siemens SIMATIC CP 1543-1

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC CP 1543-1 Vulnerabilities: Improper Access Control, Loop with Unreachable Exit Condition 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow...

9.8CVSS7.2AI score0.57333EPSS
SaveExploits2References9
ICS
ICS
•added 2019/08/13 12:00 a.m.•88 views

OSIsoft PI Web API

1. EXECUTIVE SUMMARY CVSS v3 8.5 ATTENTION: Exploitable remotely Vendor: OSIsoft LLC Equipment: OSIsoft PI Web API Vulnerabilities: Inclusion of Sensitive Information in Log Files, Protection Mechanism Failure 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow direct...

8.8CVSS8.1AI score0.01279EPSS
SaveExploits0References5
ICS
ICS
•added 2019/03/14 12:00 a.m.•88 views

LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA ELS Files

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: LCDS—Leão Consultoria e Desenvolvimento de Sistemas LTDA ME Equipment: LAquis SCADA Vulnerability: Out-of-Bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could allow remote code execution...

7.8CVSS7.8AI score0.01205EPSS
SaveExploits0References5
ICS
ICS
•added 2018/05/31 12:00 a.m.•88 views

GE MDS PulseNET and MDS PulseNET Enterprise

1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE Equipment: MDS PulseNET and MDS PulseNET Enterprise Vulnerabilities: Improper Authentication, Improper Restriction of XML External Entity Reference, Relative Path Traversal 2. RISK EVALUATION...

9.8CVSS9AI score0.1784EPSS
SaveExploits0References5
ICS
ICS
•added 2018/03/13 12:00 a.m.•88 views

OSIsoft PI Web API

CVSS v3 9.3 ATTENTION: Exploitable remotely/low skill level to exploit. Vendor: OSIsoft Equipment: PI Web API Vulnerabilities: Permissions, Privileges, and Access Controls; Cross-site Scripting AFFECTED PRODUCTS OSIsoft reports that the vulnerabilities affect the following PI Web API products: PI...

9.8CVSS7.9AI score0.01848EPSS
SaveExploits0References5
ICS
ICS
•added 2018/03/08 12:00 a.m.•88 views

ICSA-18-067-02_Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle Devices using the EN100 Ethernet Communication Module Extension (Update B)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIPROTEC 4, SIPROTEC Compact, and Reyrolle devices using the EN100 Ethernet communication module extension Vulnerability: Missing Authentication for Critical Function 2. UPDATE...

7.5CVSS7.6AI score0.01404EPSS
SaveExploits0References2
ICS
ICS
•added 2018/01/11 12:00 a.m.•88 views

WECON Technology Co., Ltd. LeviStudio HMI Editor

CVSS v3 5.3 ATTENTION: Locally exploitable/low skill level to exploit. Vendor: WECON Technology Co., Ltd. WECON Equipment: LeviStudio HMI Editor Vulnerabilities: Buffer Overflows AFFECTED PRODUCTS The following versions of LEVI Studio HMI Editor, an HMI programming software product, are affected:...

7.8CVSS8.5AI score0.02292EPSS
SaveExploits0References2
ICS
ICS
•added 2017/10/12 12:00 a.m.•88 views

Envitech Ltd. EnviDAS Ultimate

CVSS v3 8.2 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Envitech Ltd. Equipment: EnviDAS Ultimate Vulnerability: Improper Authentication AFFECTED PRODUCTS The following versions of EnviDAS Ultimate, a web application for environmental monitoring, are affected: EnviDAS...

8.2CVSS8.6AI score0.02302EPSS
SaveExploits0References3
ICS
ICS
•added 2017/07/06 12:00 a.m.•88 views

Siemens SIPROTEC 4 and SIPROTEC Compact (Update A)

CVSS v3 8.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIPROTEC 4 and SIPROTEC Compact Vulnerabilities: Improper Input Validation, Missing Authorization, Improper Authentication UPDATE INFORMATION This updated advisory is a follow-up to the original...

10CVSS1.5AI score0.74497EPSS
SaveExploits7References50
ICS
ICS
•added 2017/05/16 12:00 a.m.•88 views

Schneider Electric VAMPSET

CVSS v3 5.6 ATTENTION: Low skill level to exploit. Vendor: Schneider Electric Equipment: VAMPSET Vulnerability: Memory Corruption AFFECTED PRODUCTS Schneider Electric reports that the vulnerability affects the following VAMPSET setting and configuration software products: VAMPSET, versions prior ...

5.5CVSS5.5AI score0.00286EPSS
SaveExploits0References2
ICS
ICS
•added 2016/09/11 6:00 a.m.•88 views

Moxa MiiNePort Session Hijack Vulnerabilities

OVERVIEW Independent researcher Aditya Sood has identified vulnerabilities in Moxa’s MiiNePort. Moxa has produced new firmware editions to mitigate these vulnerabilities. These vulnerabilities could be exploited remotely. AFFECTED PRODUCTS Moxa reports that the vulnerabilities affect the followin...

7.5CVSS7.1AI score0.01633EPSS
SaveExploits0References10
ICS
ICS
•added 2016/08/19 6:00 a.m.•88 views

Lynxspring JENEsys BAS Bridge Vulnerabilities

OVERVIEW Independent researcher Maxim Rupp has identified several vulnerabilities in Lynxspring’s JENEsys BAS Bridge application. Lynxspring has discontinued the BAS Bridge application and recommends that users upgrade to the Onyxx Bridge product. These vulnerabilities could be exploited remotely...

9.8CVSS9.1AI score0.01692EPSS
SaveExploits0References10
ICS
ICS
•added 2015/03/05 12:00 p.m.•88 views

Network Time Protocol Vulnerabilities (Supplement Update A)

OVERVIEW --------- Begin Update A Part 1 of 2 -------- This advisory supplement is to accompany the NCCIC/ICS-CERT advisory titled ICSA-14-353-01C Network Time Protocol Vulnerabilities that was published February 5, 2015, on the ICS‑CERT web site. --------- End Update A Part 1 of 2 ----------...

7.5CVSS6.8AI score0.79069EPSS
SaveExploits3References28
ICS
ICS
•added 2012/05/04 6:00 a.m.•88 views

Sielco Sistemi Winlog Multiple Vulnerabilities

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-12-213-01 - Sielco Sistemi Winlog Multiple Vulnerabilities that was published July 31, 2012, on the NCCIC/ICS-CERT web site. The updated advisory matches new CVE identifiers up with other publicly available...

9.3CVSS7.8AI score0.43813EPSS
SaveExploits11References10
ICS
ICS
•added 2025/02/25 1:30 p.m.•87 views

Hitachi Energy PCU400

SUMMARY Hitachi Energy is aware of the multiple vulnerabilities related to various versions of OpenSSL library components used in PCU400 versions listed in this document below for IEC62351-3 secure for IEC104/DNP3 or PCULogger tool. These vulnerabilities if exploited, can cause confidentiality...

8.2AI score
SaveExploits0References9
ICS
ICS
•added 2024/05/28 6:00 a.m.•87 views

Campbell Scientific CSI Web Server

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION : Exploitable remotely/low attack complexity Vendor : Campbell Scientific Equipment : CSI Web Server Vulnerabilities : Path Traversal, Weak Encoding for Password 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an...

6.9CVSS5.8AI score0.00487EPSS
SaveExploits0References10
ICS
ICS
•added 2024/05/10 12:00 p.m.•87 views

#StopRansomware: Black Basta

Actions for critical infrastructure organizations to take today to mitigate cyber threats from ransomware: 1. Install updates for operating systems, software, and firmware as soon as they are released. 2. Require phishing-resistant MFA for as many services as possible. 3. Train users to recognize...

10CVSS7.9AI score0.9998EPSS
SaveExploits143References80
ICS
ICS
•added 2024/05/09 6:00 a.m.•87 views

Delta Electronics InfraSuite Device Master

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Delta Electronics Equipment : InfraSuite Device Master Vulnerability : Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow remote...

10CVSS7.8AI score0.99992EPSS
SaveExploits39References10
ICS
ICS
•added 2024/04/11 6:00 a.m.•87 views

Rockwell Automation 5015-AENFTXT (Update A)

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : 5015-AENFTXT Vulnerability : Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to crash the...

7.5CVSS6.9AI score0.02615EPSS
SaveExploits0References8
ICS
ICS
•added 2024/01/23 7:00 a.m.•87 views

Westermo Lynx 206-F2G

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.0 ATTENTION : Exploitable remotely/low attack complexity Vendor : Westermo Equipment : Lynx 206-F2G Vulnerabilities : Cross-site Scripting, Code Injection, Cross-Origin Resource Sharing, Cleartext Transmission of Sensitive Information, Cross-Site Request...

8.8CVSS6AI score0.00514EPSS
SaveExploits0References10
ICS
ICS
•added 2023/11/15 12:00 p.m.•87 views

#StopRansomware: Rhysida Ransomware

Actions to take today to mitigate malicious cyber activity: 1. Prioritize remediating known exploited vulnerabilities. 2. Enable multifactor authentication MFA for all services to the extent possible, particularly for webmail, VPN, and accounts that access critical systems. 3. Segment networks to...

10CVSS7.9AI score0.99389EPSS
SaveExploits79References119
ICS
ICS
•added 2023/05/23 6:00 a.m.•87 views

Mitsubishi Electric MELSEC Series CPU module (Update D)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION : Exploitable remotely/low attack complexity Vendor : Mitsubishi Electric Corporation Equipment : MELSEC Series CPU module Vulnerability : Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a...

10CVSS8.8AI score0.0344EPSS
SaveExploits0References10
ICS
ICS
•added 2023/04/03 7:38 p.m.•87 views

VISAM VBASE Automation Base

1. EXECUTIVE SUMMARY CVSS v3 5.5 ATTENTION: Low attack complexity Vendor: VISAM Equipment: VBASE Vulnerabilities: Improper Restriction of XML External Entity Reference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to obtain sensitive information from...

5.5CVSS5.9AI score0.04148EPSS
SaveExploits0References5
ICS
ICS
•added 2023/02/14 12:00 a.m.•87 views

Siemens RUGGEDCOM APE1808

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

7CVSS7.5AI score0.00158EPSS
SaveExploits0References12
ICS
ICS
•added 2022/09/13 12:00 a.m.•87 views

Siemens SINEC INS

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Siemens Equipment: SINEC INS Vulnerabilities: Improper Input Validation, Integer Overflow or Wraparound, Uncontrolled Resource Consumption, Command Injection, Inadequate Encryption Strength, Missing...

7.8CVSS6.7AI score0.21333EPSS
SaveExploits10References11
ICS
ICS
•added 2022/07/18 12:00 p.m.•87 views

Malicious Cyber Actors Continue to Exploit Log4Shell in VMware Horizon Systems

Summary Actions to take today: • Install fixed builds, updating all affected VMware Horizon and UAG systems to the latest versions. If updates or workarounds were not promptly applied following VMware’s release of updates for Log4Shell in December 2021,treat all affected VMware systems as...

10CVSS10AI score0.99999EPSS
SaveExploits425References89
ICS
ICS
•added 2022/05/24 12:00 a.m.•87 views

Rockwell Automation Logix Controllers

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Exploitable remotely Vendor: Rockwell Automation Equipment: Logix Controllers Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an unauthorized user to send malicious messages to...

8.6CVSS7.9AI score0.0216EPSS
SaveExploits0References4
ICS
ICS
•added 2021/12/14 12:00 a.m.•87 views

Siemens JT Utilities and JT Open Toolkit

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: JT Utilities, JT Open Toolkit Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read, Stack-based Buffer Overflow, Use After Free, Improper Restriction of Operations within the Bounds of a Memory Buffer...

7.8CVSS8AI score0.00897EPSS
SaveExploits0References11
ICS
ICS
•added 2021/10/21 12:00 a.m.•87 views

ICONICS GENESIS64 and Mitsubishi Electric MC Works64 OPC UA

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendors: ICONICS, Mitsubishi Electric Equipment: ICONICS GENESIS64, Mitsubishi Electric MC Works64 Vulnerability: Uncontrolled Recursion 2. RISK EVALUATION Successful exploitation of this vulnerability could...

7.5CVSS7.8AI score0.0195EPSS
SaveExploits0References5
ICS
ICS
•added 2021/07/13 12:00 a.m.•87 views

Siemens Teamcenter Active Workspace

1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION : Exploitable remotely/low attack complexity Vendor : Siemens Equipment : Teamcenter Active Workspace Vulnerabilities : Generation of Error Message Containing Sensitive Information, Cross-site Scripting, Exposure of Sensitive Information to an...

6.1CVSS6.4AI score0.00897EPSS
SaveExploits0References11
ICS
ICS
•added 2021/06/08 12:00 a.m.•87 views

Siemens SIMATIC TIM libcurl

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC TIM libcurl Vulnerabilities: Exposure of Sensitive Information to an Unauthorized Actor, Improper Certificate Validation 2. RISK EVALUATION Successful exploitation of these...

7.5CVSS8.5AI score0.04631EPSS
SaveExploits2References11
ICS
ICS
•added 2021/03/09 12:00 a.m.•87 views

Siemens SCALANCE and RUGGEDCOM Devices (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE and RUGGEDCOM Devices Vulnerability: Stack-based Buffer Overflow 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-068-03...

8.8CVSS9.2AI score0.00945EPSS
SaveExploits0References11
ICS
ICS
•added 2021/03/09 12:00 a.m.•87 views

Siemens SINEMA Remote Connect Server

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINEMA Remote Connect Server Vulnerabilities: Incorrect Authorization\ 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow authenticated unprivileged...

8.8CVSS9.1AI score0.00973EPSS
SaveExploits0References9
ICS
ICS
•added 2021/02/09 12:00 a.m.•87 views

SIMATIC WinCC Graphics Designer

1. EXECUTIVE SUMMARY CVSS v3 6.2 ATTENTION: Low skill level to exploit Vendor : Siemens Equipment: SIMATIC WinCC and PCS 7 Vulnerability: Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker...

5.5CVSS5.9AI score0.00336EPSS
SaveExploits0References9
ICS
ICS
•added 2019/12/19 12:00 a.m.•87 views

Moxa EDS Ethernet Switches

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Moxa Equipment: EDS-G508E, EDS-G512E, and EDS-G516E Series Ethernet Switches Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could...

7.8CVSS7.7AI score0.01333EPSS
SaveExploits0References5
ICS
ICS
•added 2019/08/29 12:00 a.m.•87 views

Philips HDI 4000 Ultrasound

1. EXECUTIVE SUMMARY CVSS v3 3.0 ATTENTION: Public exploits are available/exploitable from within the same local subnet Vendor: Philips Equipment: HDI 4000 Ultrasound Systems Vulnerability: Use of Obsolete Function 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to...

3.6CVSS4.1AI score0.00344EPSS
SaveExploits0References5
ICS
ICS
•added 2018/01/18 12:00 a.m.•87 views

ICSA-18-023-02 Siemens Industrial Products (Update A)

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit Vendor: Siemens Equipment: Industrial Products Vulnerabilities: Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled...

7.1CVSS6.7AI score0.01149EPSS
SaveExploits0References9
ICS
ICS
•added 2017/06/29 12:00 a.m.•87 views

Siemens Viewport for Web Office Portal

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: Viewport for Web Office Portal Vulnerability: Improper Authentication AFFECTED PRODUCTS Siemens reports that the vulnerability affects the following ViewPort for Web Office Portal products: ViewPort...

10CVSS10AI score0.0298EPSS
SaveExploits0References3
ICS
ICS
•added 2016/05/24 12:00 a.m.•87 views

Moxa MiiNePort Vulnerabilities (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-145-01 Moxa MiiNePort Vulnerabilities that was published May 24, 2016, on the NCCIC/ICS-CERT web site. Independent researcher Karn Ganeshen has identified weak credential management, sensitive information not...

8.8CVSS0.8AI score0.01505EPSS
SaveExploits0References19
ICS
ICS
•added 2016/05/17 12:00 a.m.•87 views

IRZ RUH2 3G Firmware Overwrite Vulnerability (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-138-01 iRZ RUH2 3G Firmware Overwrite Vulnerability that was published May 17, 2016, on the NCCIC/ICS-CERT web site. ICS-CERT has identified a firmware overwrite vulnerability in iRZ’s RUH2 device. iRZ has...

8CVSS0.1AI score0.0068EPSS
SaveExploits0References21
ICS
ICS
•added 2015/07/04 6:00 a.m.•87 views

Omron Multiple Product Vulnerabilities

OVERVIEW Air Force Institute of Technology researcher Stephen Dunlap has identified vulnerabilities in Omron Corporation’s CX-Programmer software, CJ2M series programmable logic controller PLC, and CJ2H series PLC. Omron Corporation has produced new versions that mitigate these vulnerabilities. O...

10CVSS6.4AI score0.01194EPSS
SaveExploits1References10
ICS
ICS
•added 2015/06/18 6:00 a.m.•87 views

Schneider Electric StruxureWare Building Expert Plaintext Credentials Vulnerability

OVERVIEW Independent researcher Artyom Kurbatov has identified a cleartext transmission vulnerability in Schneider Electric’s StruxureWare Building Expert product. Schneider Electric has produced a new firmware version that mitigates this vulnerability. Artyom Kurbatov has tested the new firmware...

5CVSS6.4AI score0.01199EPSS
SaveExploits0References10
ICS
ICS
•added 2013/10/26 6:00 a.m.•87 views

GE Proficy Real-Time Information Portal Information Disclosure Vulnerabilities

Overview This advisory provides mitigation details for multiple vulnerabilities that impact the GE Intelligent Platforms Proficy Real-Time Information Portal. General Electric GE has addressed two vulnerabilities in the GE Intelligent Platforms Proficy Real-Time Information Portal. Exploitation o...

5CVSS6.5AI score0.01955EPSS
SaveExploits0References10
ICS
ICS
•added 2013/08/29 12:00 p.m.•87 views

Rockwell RSLinx EDS Vulnerability

Overview ICS-CERT has received a report from Michael Orlando of CERT Coordination Center CERT/CC identifying a vulnerability in Rockwell Automation Electronic Data Sheet EDS Hardware Installation Tool. This tool is bundled with RSLinx Classic for normal distribution. The install tool exhibits a...

8.1AI score
SaveExploits0References18
ICS
ICS
•added 2013/06/19 6:00 a.m.•87 views

Emerson ROC800 Multiple Vulnerabilities (Update B)

OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-13-259-01A Emerson ROC800 Multiple Vulnerabilities that was published December 2, 2014, on the NCCIC/ICS‑CERT web site. This advisory provides mitigation details for multiple vulnerabilities affecting the Emerson...

10CVSS7.9AI score0.05036EPSS
SaveExploits0References10
ICS
ICS
•added 2012/06/09 6:00 a.m.•87 views

InduSoft ISSymbol ActiveX Control Buffer Overflow

Overview ICS-CERT received a report from Indusoft and the Zero Day Initiative ZDI concerning a heap-based buffer overflow vulnerability affecting the InduSoft ISSymbol ActiveX control. This vulnerability was reported to ZDI by security researcher Alexander Gavrun. Successful exploitation of this...

9.3CVSS7.4AI score0.32349EPSS
SaveExploits12References10
ICS
ICS
•added 2012/02/18 7:00 a.m.•87 views

Emerson DeltaV Multiple Vulnerabilities

Overview ICS-CERT originally released Advisory ICSA-12-138-01P to the US-CERT secure portal on May 17, 2012, and released Update A on May 21, 2012. This web page release including Update A was delayed to allow users time to download and install the update. Researcher Kuang-Chun Hung of the Securi...

7.5CVSS8.6AI score0.03926EPSS
SaveExploits0References10
Total number of security vulnerabilities4473