4336 matches found
Festo Didactic products
SUMMARY A vulnerability was reported in Siemens TIA Portal. TIA Portal is part of the installation packages of several Festo Didactic products. TP 260 before June 2023 and MES PC based on DELL XE3 contain a vulnerable versions of TIA Portal V15 to V18. Affected products of TIA Portal contain a...
Festo MSE6-C2M/D2M/E2M
SUMMARY Incomplete user documentation of undocumented, authenticated test mode and further remote accessible functions. The supported features may be covered only partly by the corresponding user documentation. Festo developed the products according to the respective state of the art. As a...
Hitachi Energy Relion 670, 650, SAM600-IO Series (Update A)
SUMMARY Hitachi Energy is aware of the vulnerability CVE-2022-4304 in the OSS component OpenSSL, that affects the Relion 670, 650, SAM600-IO versions that are listed below. An attacker successfully exploiting this vulnerability could send trial messages to the server and record the time taken to...
Festo Firmware
SUMMARY Incomplete Festo product documentation of remote accessible functions and their required IP ports. Depending on the product a description of the supported features can be found in the product documentation to some extent. Update A, 2022-12-13 Added affected device "Bus module CPX-E-PN,...
FESTO Hardware Controller, Hardware Servo Press Kit
SUMMARY The Festo controller CECC-X-M1 product family in multiple versions are affected by a preauthentication command injection vulnerability. Update A, 2022-07-05 Remediation has been updated. Fixed firmwares are now available. 2. IMPACT Any person who is able to gain access to the webserver...
Philips Hue Bridge Pro
RISK EVALUATION The Signify Philips Hue Bridge Pro firmware embeds a Mosquitto MQTT broker v2.0.22 that listens on all network interfaces with anonymous access enabled and no firewall restriction. An attacker with access to the Bridge's network can read device data and control connected lights...
Genkit improper host header validation
RISK EVALUATION Genkit does not properly validate host request headers. Any host on the developer's network, and any website the developer visits via DNS rebinding, can reach POST /api/runAction on the Dev UI server default port 4000 and execute any registered Genkit action and read the result...
Pulsetto Vagus Nerve Stimulator
ADVISORY SUMMARY Successful exploitation of this vulnerability could allow an attacker to use hidden commands to disable electrical safety mechanisms or modify other stimulation output settings. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of...
Siemens Desigo DXR and PXC Controllers
SUMMARY A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for...
Siemens Desigo CC
SUMMARY OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service DoS or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest...
Windscribe for Linux 'changeMTU' local privilege escalation
RISK EVALUATION A command injection vulnerability exists in Windscribe for Linux Desktop App that allows a local user who is a member of the windscribe group to execute arbitrary commands as root via the 'adapterName' parameter of the 'changeMTU' function. Fixed in Windscribe v2.18.3-alpha and...
Westermo Network Technologies WeOS 5
RISK EVALUATION Successful exploitation of this vulnerability could cause the device to reboot. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices...
OPEXUS FOIAXpress Public Access Link (PAL) SQL injection
RISK EVALUATION Successful exploitation could allow a remote, unauthenticated attacker to read, write, or delete any content in the underlying database. 2. RECOMMENDED PRACTICES Upgrade to FOIAXpress PAL version 11.13.1.0. 3. DESCRIPTION OPEXUS FOIAXpress Public Access Link PAL before version...
Schneider Electric SESU
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
Schneider Electric EcoStruxure
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install physical controls so no unauthorized personnel can access...
Delta Electronics DTN Soft
RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to use a specially crafted project file to execute arbitrary code. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:...
ControlID iDSecure On-premises
RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication, retrieve information, leak arbitrary data, or perform SQL injections. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of...
AutomationDirect C-more EA9 HMI
RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition or achieve remote code execution on the affected device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of...
Johnson Controls Simplex Incident Manager
ADVISORY SUMMARY Successful exploitation of this vulnerability could allow a local attacker with low privileges to extract user credentials passwords and authentication tokens from system memory, potentially leading to unauthorized access to the application and connected systems. 2. RECOMMENDED...
Siemens SiPass Integrated
SUMMARY SiPass integrated before V3.0 contains multiple vulnerabilities that could allow an unauthenticated remote attacker to exploit user accounts, manipulate data, impersonate users, or achieve arbitrary code execution on the SiPass integrated server. Siemens has released a new version for...
Hitachi Energy RTU500 series
RISK EVALUATION Successful exploitation of these vulnerabilities could cause a Denial-of-Service condition in RTU500 devices. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure...
Siemens SIMATIC NET CP, SINEMA and SCALANCE
RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service DoS condition in the affected devices by exploiting integer overflow bugs. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of...
Burk Technology ARC Solo
RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker gaining access to the device, locking out authorized users, or disrupting operations. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this...
Rockwell Automation Lifecycle Services with VMware
RISK EVALUATION Successful exploitation of these vulnerabilities could lead to code execution on the host or leakage of memory from processes communicating with vSockets. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these...
LS Electric GMWin 4
RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose information or execute arbitrary code. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize...
AVEVA PI Data Archive
RISK EVALUATION Successful exploitation of these vulnerabilities could shut down necessary subsystems and cause a denial-of-service condition. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize...
Siemens RUGGEDCOM CROSSBOW
SUMMARY RUGGEDCOM CROSSBOW Station Access Controller SAC contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code or to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station...
Siemens OpenSSL Vulnerability in Industrial Products
RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial-of-service condition. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this...
Flow Neuroscience FL-100
ADVISORY SUMMARY Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to manipulate brain stimulation parameters and override safety limits. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this...
Shelly Pro 3EM
RISK EVALUATION Successful exploitation of this vulnerability could result in a denial-of-service condition. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control...
Siemens Altair Grid Engine
SUMMARY Altair Grid Engine contain multiple vulnerabilities that could allow an attacker to escalate privileges and execute arbitrary code with superuser permissions. Siemens has released a new version for Altair Grid Engine and recommends to update to the latest version. 2. GENERAL...
Schneider Electric Saitel DR & Saitel DP Remote Terminal Unit
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
Siemens SINEC Traffic Analyzer
SUMMARY SINEC Traffic Analyzer before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are...
Festo LX Appliance
SUMMARY A vulnerability in the Video.js package could allow a user of LX Appliance, with a high privilege account i.e., with the "Teacher" role, to craft a malicious course and launch an XSS attack. 2. REMEDIATION Contact Festo Didactic services department at [email protected] to...
Google Turbinia arbitrary command execution
RISK EVALUATION Google Turbinia allows arbitrary command execution via worker tasks. An attacker with privileges to submit a processing request or influence an evidence path/name obtains code execution on the worker fleet. 2. RECOMMENDED PRACTICES Fixed on 2026-07-10, update to a version...
Siemens Parasolid
SUMMARY Parasolid is affected by an out of bounds read vulnerability that could be triggered when the application reads files in XT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends...