Lucene search

K
icsIndustrial Control Systems Cyber Emergency Response TeamICSA-19-344-01
HistoryDec 10, 2019 - 12:00 p.m.

Siemens SCALANCE W700 and W1700

2019-12-1012:00:00
Industrial Control Systems Cyber Emergency Response Team
www.cisa.gov
38

6.5 Medium

CVSS3

Attack Vector

ADJACENT_NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

7.1 High

AI Score

Confidence

High

3.3 Low

CVSS2

Access Vector

ADJACENT_NETWORK

Access Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:A/AC:L/Au:N/C:P/I:N/A:N

0.001 Low

EPSS

Percentile

44.9%

1. EXECUTIVE SUMMARY

  • CVSS v3 6.5 ***ATTENTION: **Low skill level to exploit
  • Vendor: Siemens
  • **Equipment:**SCALANCE W700 and W1700
  • Vulnerability: Improper Enforcement of Message Integrity During Transmission in a Communication Channel

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to access confidential data.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of SCALANCE W700 and W1700, wireless communication devices, are affected:

  • SCALANCE W700 Versions 6.3 and prior
  • SCALANCE W1700 Versions 1.0 and prior

3.2 VULNERABILITY OVERVIEW

3.2.1 IMPROPER ENFORCEMENT OF MESSAGE INTEGRITY DURING TRANSMISSION IN A COMMUNICATION CHANNEL CWE-924

Under certain conditions, the integrity of EAPOL-key messages might not be checked, leading to a decryption oracle. This could be exploited by an attacker within range of the access point, which could allow the abuse of the vulnerability to access confidential data.

CVE-2018-14526 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens recommends installing the following software updates to address this vulnerability:

Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:

  • Whenever possible, use AES-CCMP instead of TKIP in the WPA/WPA2 networks. This can be configured for both the SCALANCE W-700 and W-1700 families over the Web Based Management (web server). For more information, go for the respective Manual.

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for Industrial Security and to follow the recommendations in the product manuals.

Additional information on Industrial Security by Siemens can be found at:

<https://www.siemens.com/industrialsecurity&gt;

For more information on this vulnerability and more detailed mitigation instructions, please see Siemens security advisory SSA-344983 at the following location:

<http://www.siemens.com/cert/advisories&gt;

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:

  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.

References

6.5 Medium

CVSS3

Attack Vector

ADJACENT_NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

7.1 High

AI Score

Confidence

High

3.3 Low

CVSS2

Access Vector

ADJACENT_NETWORK

Access Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:A/AC:L/Au:N/C:P/I:N/A:N

0.001 Low

EPSS

Percentile

44.9%