3516 matches found
CVE-2014-2355 GE Proficy HMI/SCADA CIMPLICITY CimView
The 1 CimView and 2 CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen aka .CIM file...
CVE-2014-2355
The CVE-2014-2355 vulnerability affects GE Proficy HMI/SCADA–CIMPLICITY CimView and CimEdit components (versions 8.2 and earlier). The issue is a memory access violation when processing CIMPLICITY screen files (.CIM), potentially enabling privilege escalation within the application. Publicly disc...
Siemens SIMATIC HMI Devices Vulnerabilities (Update E)
OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-15-099-01D Siemens SIMATIC HMI Devices Vulnerabilities that was published September 10, 2015, on the NCCIC/ICS‑CERT web site. Siemens has identified three vulnerabilities in its SIMATIC HMI devices. These...
StruxureWare SCADA Expert ClearSCADA Remote Security Bypass
Binary data scadaclearscadaremotesecuritybypass.nbin...
Ecava IntegraXor DLL Vulnerabilities
OVERVIEW Security researcher Praveen Darshanam has identified two DLL loading vulnerabilities in Ecava’s IntegraXor SCADA Server. Ecava has produced a patch that mitigates these vulnerabilities. Praveen Darshanam has tested the patch to validate that it resolves the vulnerabilities. AFFECTED...
Advantech WebAccess SCADA webeye.ocx ip_address Parameter Buffer Overflow - ver 2 (CVE-2014-8388)
A stack buffer overflow exists in Advantech's WebAccess SCADA software. The vulnerability is due to insufficient input validation of the ipaddress parameter contained in the webeye.ocx ActiveX control, a part of the WebAccess Client. A remote, unauthenticated attacker could exploit this...
Advantech WebAccess HMI and SCADA Software CrossSite Scripting - Ver2 (CVE-2012-0233)
A cross-site scripting vulnerability has been reported in Advantech Webaccess. Successful exploitation of this vulnerability would allow remote attackers to inject arbitrary web script into the affected system...
Procyon Core Server HMI Memory Corruption SCADA Remote Code Execution - Ver2 (CVE-2011-3322)
A remote stack overflow vulnerability has been reported in Procyon Core Server HMI service. The vulnerability is due to a boundary check error. A remote attacker may exploit this issue by sending specially crafted messages to the target server. Successful exploitation could allow an attacker to...
HP's Zero Day Initiative Changes Bug-Buying Guidelines
HP’s Zero Day Initiative has decided to adjust its guidelines and criteria or buying some vulnerabilities in the future, eliminating some large classes of bugs from its menu. The group, which has been among the more visible and prominent of the vulnerability purchasing programs since its inceptio...
Industrial safety: BlackEnergy(dark)the use of the Siemens WinCC system has been repaired loopholes to launch attacks-vulnerability warning-the black bar safety net
Researchers recently found that the malware BlackEnergy(dark forces are using Siemens SIMATIC WinCC(Siemens the most classic process monitoring system has been repaired loopholes to re-attack the SCADA HMI system. ! Comeback: the BlackEnergy then update the BlackEnergy(dark)is an automated networ...
Soitec SmartEnergy 1.4 SCADA Login SQL Injection Authentication Bypass Exploit
Soitec SmartEnergy web application suffers from an authentication bypass vulnerability using SQL Injection attack in the login script. The script fails to sanitize the 'login' POST parameter allowing the attacker to bypass the security mechanism and view sensitive information that can be further...
Soitec SmartEnergy 1.4 - SCADA Login SQL Injection Authentication Bypass
Soitec SmartEnergy 1.4 - SCADA Login SQL Injection Authentication Bypass Soitec SmartEnergy 1.4 SCADA Login SQL Injection Authentication Bypass Exploit Vendor: Soitec Product web page: http://www.soitec.com Affected version: 1.4 and 1.3 Summary: Soitec power plants are a profitable and ecological...
Soitec SmartEnergy 1.4 SCADA Login SQL Injection Authentication Bypass
Soitec SmartEnergy 1.4 SCADA Login SQL Injection Authentication Bypass Exploit Vendor: Soitec Product web page: http://www.soitec.com Affected version: 1.4 and 1.3 Summary: Soitec power plants are a profitable and ecological investment at the same time. Using Concentrix technology, Soitec offers...
Schneider Electric StruxureWare SCADA Expert ClearSCADA Parsing Vulnerability
OVERVIEW Andrew Brooks identified and reported to The Zero Day Initiative ZDI a File Parsing Vulnerability: Schneider Electric StruxureWare SCADA Expert ClearSCADA ServerMain.exe OPF File Parsing Vulnerability. Schneider Electric has prepared workarounds and helped develop security upgrades for a...
CVE-2014-5429
DNP Master Driver 3.02 and earlier in Elipse SCADA 2.29 build 141 and earlier, E3 1.0 through 4.6, and Elipse Power 1.0 through 4.6 allows remote attackers to cause a denial of service CPU consumption via malformed packets...
Code injection
DNP Master Driver 3.02 and earlier in Elipse SCADA 2.29 build 141 and earlier, E3 1.0 through 4.6, and Elipse Power 1.0 through 4.6 allows remote attackers to cause a denial of service CPU consumption via malformed packets...
CVE-2014-5429
DNP Master Driver 3.02 and earlier in Elipse SCADA 2.29 build 141 and earlier, E3 1.0 through 4.6, and Elipse Power 1.0 through 4.6 allows remote attackers to cause a denial of service CPU consumption via malformed packets...
CVE-2014-5429
CVE-2014-5429 affects the DNP Master Driver (V3.02 and earlier) used by Elipse SCADA, Elipse E3 (V1.0–V4.6), and Elipse Power (V1.0–V4.6). The root cause is handling of malformed DNP packets, leading to resource exhaustion and a denial of service (CPU consumption). Affected products can become un...
Elipse SCADA Denial of Service Patch
Brazilian process management software developer Elipse has patched a serious denial-of-service vulnerability in its web-based Elipse SCADA application. The software is used in a number of critical industries worldwide, including manufacturing, energy, water and wastewater plants. The vulnerabilit...
Researcher Releases Database of Known-Good ICS and SCADA Files
A prominent security researcher has put together a new database of hundreds of thousands of known-good files from ICS and SCADA software vendors in an effort to help users and other researchers identify legitimate files and home in on potentially malicious ones. The database, known as WhiteScope,...