Lucene search
+L

3516 matches found

ThreatPost
ThreatPost
added 2014/10/07 2:49 p.m.30 views

Siemens Patches Five Vulnerabilities in SIMATIC WinCC for PCS 7

Siemens has patched five vulnerabilities in its SIMATIC PCS 7 system that could result in privilege escalation and give an attacker unauthenticated access to sensitive data. The flaws technically exist in WinCC, a SCADA supervisory control and data acquisition and HMI human-machine interface syst...

6CVSS0.5AI score0.01686EPSS
SaveExploits0References1
seebug.org
seebug.org
added 2014/09/29 12:0 a.m.46 views

WS10 Data Server SCADA Exploit Overflow PoC

No description provided by source. Exploit Title: WS10 Data Server SCADA Exploit Overflow PoC Date: 09/23/2014 Author: Pedro Sánchez Version: 1.83 English Tested on: Windows 7 embedded. Notified the vendor, vendor never responded. In the new version this PoC stops working Vendor: Novus...

7.1AI score
SaveExploits0
ThreatPost
ThreatPost
added 2014/09/25 2:34 p.m.73 views

Patching Bash Vulnerability a Challenge for ICS, SCADA

While the most urgent focus where the Bash vulnerability is concerned is around Internet-facing web servers, embedded systems and industrial control systems are not exempt from worry. Experts are concerned about Linux-based industrial control systems and SCADA equipment, in particular, that may b...

10CVSS0.1AI score0.99999EPSS
SaveExploits137References4
Packet Storm
Packet Storm
added 2014/09/25 12:0 a.m.46 views

WS10 Data Server SCADA Overflow

Exploit Title: WS10 Data Server SCADA Exploit Overflow PoC Date: 09/23/2014 Author: Pedro Sánchez Version: 1.83 English Tested on: Windows 7 embedded. Notified the vendor, vendor never responded. In the new version this PoC stops working Vendor: Novus http://www.novus.com.br NOVUS Electronics is ...

0.3AI score
SaveExploits0
OpenVAS
OpenVAS
added 2014/09/25 12:0 a.m.28 views

7T Interactive Graphical SCADA System 'dc.exe' Command Injection Vulnerability

7T Interactive Graphical SCADA System is prone to a remote command execution RCE vulnerability. SPDX-FileCopyrightText: 2014 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only...

10CVSS6.7AI score0.66982EPSS
SaveExploits10References4
Tenable Nessus
Tenable Nessus
added 2014/09/24 12:0 a.m.12 views

IEC 60870-5-104 Client Detection (SCADA)

Binary data 8371.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2014/09/24 12:0 a.m.19 views

IEC 60870-5-104 Server Detection (SCADA)

Binary data 6597.prm...

7.3AI score
SaveExploits0
zdt
zdt
added 2014/09/24 12:0 a.m.47 views

WS10 Data Server SCADA Overflow PoC Exploit

WS10 Data Server version 1.83 SCADA buffer overflow proof of concept exploit. Exploit Title: WS10 Data Server SCADA Exploit Overflow PoC Date: 09/23/2014 Author: Pedro Sánchez Version: 1.83 English Tested on: Windows 7 embedded. Notified the vendor, vendor never responded. In the new version this...

7.5AI score
SaveExploits0
exploitpack
exploitpack
added 2014/09/24 12:0 a.m.43 views

WS10 Data Server - SCADA Overflow (PoC)

WS10 Data Server - SCADA Overflow PoC Exploit Title: WS10 Data Server SCADA Exploit Overflow PoC Date: 09/23/2014 Author: Pedro Sánchez Version: 1.83 English Tested on: Windows 7 embedded. Notified the vendor, vendor never responded. In the new version this PoC stops working Vendor: Novus...

0.3AI score
SaveExploits0
Exploit DB
Exploit DB
added 2014/09/24 12:0 a.m.50 views

WS10 Data Server - SCADA Overflow (PoC)

Exploit Title: WS10 Data Server SCADA Exploit Overflow PoC Date: 09/23/2014 Author: Pedro Sánchez Version: 1.83 English Tested on: Windows 7 embedded. Notified the vendor, vendor never responded. In the new version this PoC stops working Vendor: Novus http://www.novus.com.br NOVUS Electronics is ...

5.3AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
added 2014/09/23 12:0 a.m.22 views

Advantech WebAccess SCADA Password Parameter Buffer Overflow (CVE-2014-0992)

A stack buffer overflow exists in Advantech's WebAccess SCADA software. The vulnerability is due to insufficient input validation of the Password parameter in an ActiveX control that is part of the WebAccess Client. A remote, unauthenticated attacker could exploit this vulnerability by enticing a...

6.8CVSS6.7AI score0.02569EPSS
SaveExploits0
NVD
NVD
added 2014/09/18 10:55 a.m.28 views

CVE-2014-5411

Multiple cross-site scripting XSS vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors...

4.9CVSS5.3AI score0.01287EPSS
SaveExploits0References3
Prion
Prion
added 2014/09/18 10:55 a.m.26 views

Code injection

Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm...

5CVSS7AI score0.01028EPSS
SaveExploits0References1Affected Software2
CVE
CVE
added 2014/09/18 10:0 a.m.64 views

CVE-2014-5412

Schneider Electric SCADA Expert ClearSCADA/ ClearSCADA (2010 R3 through 2014 R1) contains an authentication bypass via the default guest account, enabling remote disclosure of database records. Root cause: guest user’s read access exposes sensitive data without login. Affected products/versions: ...

6.4CVSS6.7AI score0.01572EPSS
SaveExploits0References3Affected Software2
Cvelist
Cvelist
added 2014/09/18 10:0 a.m.36 views

CVE-2014-5413 Schneider Electric SCADA Expert ClearSCADA Cryptographic Issues

Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm...

6.4CVSS6.5AI score0.01028EPSS
SaveExploits0References2
CVE
CVE
added 2014/09/18 10:0 a.m.58 views

CVE-2014-5413

CVE-2014-5413 affects Schneider Electric StruxureWare SCADA Expert ClearSCADA (2010 R3 through 2014 R1). The root issue is weak cryptographic controls: the self-signed web certificate uses MD5, enabling potential cryptographic spoofing of servers. Additionally, ICS-CERT describes a cross-site scr...

6.4CVSS6.7AI score0.01028EPSS
SaveExploits0References3Affected Software2
Cvelist
Cvelist
added 2014/09/18 10:0 a.m.35 views

CVE-2014-5412 Schneider Electric SCADA Expert ClearSCADA Improper Authentication

Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account...

6.4CVSS6.5AI score0.01572EPSS
SaveExploits0References2
CVE
CVE
added 2014/09/18 10:0 a.m.50 views

CVE-2014-5411

Schneider Electric SCADA Expert ClearSCADA (ClearSCADA 2010 R3 through 2014 R1; SCADA Expert ClearSCADA 2013/2014 R1 variants) is affected by CVE-2014-5411, a cross-site scripting (XSS) vulnerability combined with an authentication bypass and a weak MD5-based self-signed certificate issue. The IC...

4.9CVSS5.4AI score0.01287EPSS
SaveExploits0References3Affected Software2
ThreatPost
ThreatPost
added 2014/09/17 1:56 p.m.10 views

Series of Vulnerabilities Found in Schneider Electric SCADA Products

UPDATE–There are several unpatched, remotely exploitable vulnerabilities in a number of Schneider Electric’s SCADA products, one of which could be used to perform a shutdown of the SCADA server. Another of the vulnerabilities is an authentication bypass that could give an attacker access to...

2.1AI score
SaveExploits0References1
NVD
NVD
added 2014/09/15 2:55 p.m.27 views

CVE-2014-2377

Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to discover full pathnames via an application tag...

5CVSS6.6AI score0.01836EPSS
SaveExploits0References2
Rows per page