3516 matches found
Advantech WebAccess SCADA webeye.ocx ip_address Parameter Buffer Overflow (CVE-2014-8388)
A stack buffer overflow exists in Advantech's WebAccess SCADA software. The vulnerability is due to insufficient input validation of the ipaddress parameter contained in the webeye.ocx ActiveX control, a part of the WebAccess Client. A remote, unauthenticated attacker could exploit this...
Siemens Patches WinCC Vulnerabilities Likely Being Exploited
Global industrial supplier Siemens has patched two critical vulnerabilities that it believes are likely being exploited. Organizations running products using the Siemens WinCC application are urged to apply available patches immediately; the company said it is working on updates for any remaining...
Elipse E3 - HTTP Denial of Service
// Exploit Http DoS Request for SCADA ATTACK Elipse 3 // Mauro Risonho de Paula Assumpção aka firebits // [email protected] // 29-10-2013 11:42 // Vendor Homepage: http://www.elipse.com.br/port/index.aspx // Software Link: http://www.elipse.com.br/port/e3.aspx // Version: 3.x and prior //...
Elipse E3 - HTTP Denial of Service
Elipse E3 - HTTP Denial of Service // Exploit Http DoS Request for SCADA ATTACK Elipse 3 // Mauro Risonho de Paula Assumpção aka firebits // [email protected] // 29-10-2013 11:42 // Vendor Homepage: http://www.elipse.com.br/port/index.aspx // Software Link:...
Buffer Overflow Haunts Advantech WebAccess SCADA Product
The ICS-CERT is warning users about a stack buffer overflow in the Advantech WebAccess SCADA product that could lead to arbitrary code execution. Advantech WebAccess is a SCADA and human-machine interface product that’s accessible over the Web. It’s used in a variety of industries, including...
Advantech WebAccess 7.2 Stack-Based Buffer Overflow Vulnerability
Advantech WebAccess version 7.2 is vulnerable to a stack-based buffer overflow attack, which can be exploited by remote attackers to execute arbitrary code, by providing a malicious html file with specific parameters for an ActiveX component. Advantech WebAccess Stack-based Buffer Overflow 1...
Nordex NC2 'username' Parameter Cross Site Scripting Vulnerability
Nordex NC2 is prone to a cross-site scripting XSS vulnerability. SPDX-FileCopyrightText: 2014 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
CVE-2014-5408
Cross-site scripting XSS vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 NC2 SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter...
Cross site scripting
Cross-site scripting XSS vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 NC2 SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter...
CVE-2014-5408
CVE-2014-5408 is a reflected XSS in the Nordex NC2 Wind Farm Portal login script (username parameter) affecting NC2 v15 and earlier. The vulnerability, exploitable remotely, can cause a user’s browser to execute arbitrary script/HTML; OpenVAS notes the potential to read cookies during exploitatio...
CVE-2014-5408 Nordex NC2 Cross-site Scripting
Cross-site scripting XSS vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 NC2 SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter...
Destructive BlackEnergy Malware Plug-Ins Target Cisco Routers
BlackEnergy, a converted crimeware tool, operates behind a laundry list of plug-ins for Linux and Windows systems that allows it to be used to attack Cisco networking devices, steal digital certificates, brick systems it infects, and skillfully hide from security analysts. Researchers from...
GE Proficy Vulnerabilities
OVERVIEW Researchers amisto0x07 and Z0mb1E of Zero Day Initiative ZDI have identified two vulnerabilities in the General Electric GE Proficy human-machine interface/supervisory control and data acquisition HMI/SCADA - CIMPLICITY application. GE has released security advisories, GEIP13-05 and...
Ecava IntegraXor Buffer Overflow Vulnerability
OVERVIEW This advisory is a follow-up to the alert titled ICS-ALERT-14-015-01 Ecava IntegraXor Buffer Overflow Vulnerability that was published January 15, 2014, on the NCCIC/ICS-CERT Web site. Independent researcher Luigi Auriemma identified a buffer overflow vulnerability in the Ecava IntegraXo...
Schneider Electric SCADA Expert ClearSCADA Denial of Service (CVE-2014-5411)
A denial of service vulnerability exists in Schneider Electric SCADA Expert ClearSCADA. The vulnerability is due to insufficient validation of incoming requests. A remote attacker can exploit this vulnerability by enticing an authenticated user to view crafted web content. This can result in a...
Schneider Electric ClearSCADA Uncontrolled Resource Consumption Vulnerability
OVERVIEW Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an uncontrolled resource consumption vulnerability in the Schneider Electric SCADA Expert ClearSCADA software. Schneider Electric has produced a new version that mitigates this vulnerability. Adam Crain has...
Schneider Electric SCADA Expert ClearSCADA < 2014 R1.1 and Schneider Electric ClearSCADA < 2010 R3.2 Multiple Vulnerabilities
Binary data 8391.prm...
Advantech WebAccess SCADA ProjectName Parameter Buffer Overflow (CVE-2014-0991)
A stack buffer overflow exists in Advantech's WebAccess SCADA software. This is due to insufficient input validation of the ProjectName parameter contained in the webvact.ocx ActiveX control, a part of the WebAccess Client. A remote, unauthenticated attacker could exploit this vulnerability by...
MatrikonOPC Improper Input Validation
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on January 10, 2014, and is now being released to the NCCIC/ICS-CERT web site. Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation vulnerability in the...
Schneider Electric SCADA Expert ClearSCADA Authentication Bypass (CVE-2014-5412)
An information disclosure vulnerability exists in Schneider Electric SCADA Expert ClearSCADA. This vulnerability is due to insufficient restrictions of the preconfigured guest account. A remote attacker can exploit this vulnerability to disclose sensitive system information...