Rockwell Automation RSLinx Classic < 3.73.00 Buffer Overflow
Binary data scadarslinxclassic37300.nbin...
The Triumphant Finale of CSI: Cyber
It’s been a couple of months since we left our heroes on CSI: Cyber, and boy, have they been busy. They have apparently solved many crimes using cyber-sleuthing, acquired some decidedly non-cyber firearms skills, and, in the case of our man Krumitz, taken up running. We wanted to check in and see...
EtherNet/IP CIP List of Active Object Classes
Binary data scadacipclasslist.nbin...
EtherNet/IP CIP Device Identification
Binary data scadaciplistidentity.nbin...
Open Smart Grid Protocol Homegrown Crypto Weaknesses
In the three years since its inception, the Open Smart Grid Protocol has found its way into more than four million smart meters and similar devices worldwide. And like its SCADA, industrial control system, and embedded system brethren, it’s rife with security issues. Two researchers, Phillip...
Honeywell XLWEB SCADA Path Traversal
SCADA - EXPLOITING CVE-2015-0984 FOR SHELL ACCESS This post is a follow up detailing how to achieve control of the actual XLWEB SCADA controller. The vulnerability is assigned with reference CVE-2015-0984. Rather than the application level administrative access as discussed in the email regarding...
Dell Threat Report Claims 100 Percent Increase in SCADA Attacks
In 2014, there were increases in malware designed to target retail point-of-sale systems and attack supervisory control and data acquisition SCADA systems, according to Dell’s annual threat report. The report pdf was released, interestingly enough, just one day before Verizon’s industry standard...
Elipse SCADA DLL Hijacking Vulnerability
Elipse SCADA is a WEB-based SCADA system deployed in critical manufacturing, energy, hydro and other systems. The program suffers from a DLL hijacking vulnerability when loading a DLL pointing to a DLL named wfapi.dll, which could be exploited by an attacker to build a malicious application that,...
SCADA Engine BACnet OPC Server < 2.1.371.24 Multiple Vulnerabilities
Binary data scadabacnetopcserver2137124.nbin...
CVE-2015-0990
Untrusted search path vulnerability in Ecava IntegraXor SCADA Server before 4.2.4488 allows local users to gain privileges via a renamed DLL in the default install directory...
Design/Logic Flaw
Untrusted search path vulnerability in Ecava IntegraXor SCADA Server before 4.2.4488 allows local users to gain privileges via a renamed DLL in the default install directory...
CVE-2015-0990
Affected product: Ecava IntegraXor SCADA Server prior to version 4.2.4488. Issue: Untrusted search path (CWE-427) allows a local attacker to escalate privileges by placing a renamed DLL in the default install directory; the DLL is loaded by the application, executing code with the application’s p...
CVE-2015-0990
Untrusted search path vulnerability in Ecava IntegraXor SCADA Server before 4.2.4488 allows local users to gain privileges via a renamed DLL in the default install directory...
Inductive Automation Ignition Invalid Session Expires Vulnerability
Ignition is an updated version of FactoryPMI, the HMI/SCADA product offered by Inductive Automation. Ignition does not delete the session after the user logs out, which can allow an attacker to reuse the current session...
Cimon CmnView DLL Hijacking Vulnerability
CmnView is a WEB-based SCADA application. The CmnView application contains a DLL that fails to specify an absolute path, allowing an attacker to exploit the vulnerability to build a malicious application and place it in a specific path, which could allow the application to maliciously load the DL...
CVE-2015-0981
The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...
CVE-2015-0980
Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...
CVE-2015-0979
Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...
Format string
Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...
Authentication flaw
The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...