Lucene search
+L

3516 matches found

Prion
Prion
added 2015/03/14 1:59 a.m.22 views

Heap overflow

Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...

9CVSS8.6AI score0.04564EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2015/03/14 1:00 a.m.38 views

CVE-2015-0979

Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...

7.9AI score0.04564EPSS
SaveExploits0References1
CVE
CVE
added 2015/03/14 1:00 a.m.105 views

CVE-2015-0979

Summary (CVE-2015-0979) : A heap-based buffer overflow in the SOAP web interface of the SCADA Engine BACnet OPC Server prior to version 2.1.371.24 allows remote arbitrary code execution via a crafted packet. The affected component is the Windows Service SOAP interface; exploitation is remote and ...

9CVSS8.2AI score0.04564EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2015/03/14 1:00 a.m.59 views

CVE-2015-0980

SCADA Engine BACnet OPC Server (BACnet OPC Server) before version 2.1.371.24 is affected by CVE-2015-0980 via a format-string vulnerability in the SOAP web interface (BACnOPCServer.exe). Exploitation could allow remote attackers to execute arbitrary code. The ICS-CERT advisory notes a fixed versi...

9CVSS7.8AI score0.03616EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2015/03/14 1:00 a.m.41 views

CVE-2015-0980

Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...

7.5AI score0.03616EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2015/03/14 1:00 a.m.44 views

CVE-2015-0981

The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...

7AI score0.02575EPSS
SaveExploits0References1
CVE
CVE
added 2015/03/14 1:00 a.m.66 views

CVE-2015-0981

SCADA Engine BACnet OPC Server prior to version 2.1.371.24 is affected by three vulnerabilities tied to the SOAP web interface: (1) CVE-2015-0981 Authentication bypass allowing remote read/write of database fields, (2) CWE-122 Heap-based Buffer Overflow, and (3) CWE-20 Improper Input Validation. ...

7.5CVSS7.2AI score0.02575EPSS
SaveExploits0References1Affected Software1
The Hacker News
The Hacker News
added 2015/03/12 12:56 a.m.13 views

This 'Killer USB' can make your Computer explode

Can Hackers turn a remote computer into a bomb and explode it to kill someone, just like they do in hacker movies? Wait, wait! Before answering that, Let me tell you an interesting story about Killer USB drive: A man walking in the subway stole a USB flash drive from the outer pocket of someone...

6.4AI score
SaveExploits0
CNVD
CNVD
added 2015/03/09 12:00 a.m.12 views

MICROSYS PROMOTIC Buffer Overflow Vulnerability

MICROSYS PROMOTIC is a SCADA software. MICROSYS PROMOTIC suffers from a buffer overflow vulnerability that can be exploited by an attacker to execute arbitrary code or launch a denial-of-service attack within the context of the application because the program fails to properly bounds check...

7.5CVSS8.1AI score0.04747EPSS
SaveExploits0References1
ThreatPost
ThreatPost
added 2015/02/24 2:22 p.m.16 views

Attacks Against Critical Infrastructure Seek Operational Intel

In most critical industries—petroleum refineries or energy utilities, for example—there is very little in the way of proprietary information. Refining crude oil into gasoline requires science, not a secret sauce. Same goes for power generation. So why are advanced attackers using the same data...

0.3AI score
SaveExploits0References7
ThreatPost
ThreatPost
added 2015/02/19 7:47 a.m.17 views

'Yes, Your Car Wash is On Facebook'

CANCUN–When or if people think about the security of the devices they interact with and use on a daily basis, the machines that run their local car wash probably aren’t high up on that list. But, like everything else with a computer for a brain these days, those machines are connected to the...

1.2AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2015/02/16 12:00 a.m.16 views

Siemens SCALANCE X-200IRT < 5.2.0 Session Hijacking

Binary data scadasiemensscalancex200cve-2015-1049.nbin...

6.8CVSS6.6AI score0.01698EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2015/02/11 12:00 a.m.19 views

Siemens SIMATIC TIA Portal Detection

Binary data scadaappsiemenstiadetect.nbin...

7.3AI score
SaveExploits0References1
ThreatPost
ThreatPost
added 2015/02/09 8:20 a.m.12 views

Siemens Fixes Critical Flaws in Some WinCC Versions

More than two months after the original advisory went out, Siemens has released patches for a pair of critical vulnerabilities in some versions of its Simatic WinCC SCADA product that remained vulnerable. Both of the vulnerabilities are remotely exploitable and have potentially damaging...

4.1AI score
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2015/01/30 12:00 a.m.21 views

Schneider Electric Multiple Products Buffer Overflow

Binary data scadaschneiderelectriccve20149200.nbin...

7.5CVSS7.3AI score0.05567EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2015/01/28 12:00 a.m.30 views

StruxureWare SCADA Expert ClearSCADA Weak Hashing Algorithm

Binary data scadaclearscadaweakhashingalgorithm.nbin...

6.4CVSS7.3AI score0.01028EPSS
SaveExploits0References3
CNVD
CNVD
added 2015/01/22 12:00 a.m.15 views

Schneider Electric ETG3000 FactoryCast HMI Gateway Unauthorized Access Vulnerability

The Schneider Electric ETG3000 FactoryCast HMI Gateway is a Web-based SCADA system. An unauthorized access vulnerability exists in the Schneider Electric ETG3000 FactoryCast HMI Gateway, which could be exploited by an attacker to gain unauthorized access to sensitive information, such as...

10CVSS6.9AI score0.01957EPSS
SaveExploits0References1
ThreatPost
ThreatPost
added 2015/01/21 10:17 a.m.15 views

Hard-Coded FTP Credentials Found in Schneider Electric SCADA Gateway

The parade of easily exploitable, critical vulnerabilities in ICS software shows no signs of ending anytime soon, with the latest entrant being two flaws in Schneider Electric’s ETG3000 FactoryCast HMI Gateway that allow unauthenticated remote access to the device’s FTP server and configuration...

2.9AI score
SaveExploits0References1
Prion
Prion
added 2015/01/17 2:59 a.m.21 views

Code injection

The 1 CimView and 2 CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen aka .CIM file...

6.9CVSS7.3AI score0.00645EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2015/01/17 2:59 a.m.23 views

CVE-2014-2355

The 1 CimView and 2 CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen aka .CIM file...

6.9CVSS6.8AI score0.00645EPSS
SaveExploits0References2
Rows per page