Lucene search
+L

823 matches found

CNNVD
CNNVD
added 2022/07/13 12:00 a.m.7 views

多款Schneider Electric产品数据伪造问题漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

7.5CVSS7.4AI score0.00279EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.11 views

多款Schneider Electric产品代码问题漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

7.5CVSS7.5AI score0.00868EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.10 views

多款Schneider Electric产品安全漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

7.5CVSS7.4AI score0.00762EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.11 views

多款Schneider Electric产品路径遍历漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

7.5CVSS7.4AI score0.00696EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.13 views

多款Schneider Electric产品缓冲区错误漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

7.5CVSS7.6AI score0.00671EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2022/07/12 11:00 a.m.7 views

CVE-2022-34760

A CWE-835: Loop with Unreachable Exit Condition 'Infinite Loop' vulnerability exists that could cause a denial of service of the webserver due to improper handling of the cookies. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V1.0, OPC UA Modicon Communication Module...

7.5CVSS5.9AI score0.00762EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2022/07/12 11:00 a.m.6 views

CVE-2022-34765

A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication...

5.5CVSS5.9AI score0.00551EPSS
SaveExploits0References2Affected Software1
ATTACKERKB
ATTACKERKB
added 2022/07/12 11:00 a.m.7 views

CVE-2022-34759

A CWE-787: Out-of-bounds Write vulnerability exists that could cause a denial of service of the webserver due to improper parsing of the HTTP Headers. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V1.0, OPC UA Modicon Communication Module BMENUA0100 V1.10 and prior...

7.5CVSS5.9AI score0.00762EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/06/28 12:00 a.m.12 views

Motorola Solutions ACE1000 信任管理问题漏洞

The Motorola Solutions ACE1000 is a Remote Terminal Unit from Motorola Solutions USA. A security vulnerability exists in the Motorola Solutions ACE1000 RTU version, which stems from a hard-coded SSH private key shipped with the affected product, and can be exploited by an attacker to manipulate...

9.8CVSS8.3AI score0.00977EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2022/06/22 12:00 a.m.11 views

PT-2022-3174 · Emerson · Emerson Roc +1

Name of the Vulnerable Software and Affected Versions: Emerson ROC and FloBoss RTU product lines through 2022-05-02 Description: The issue is related to insecure filesystem operations in the Emerson ROC and FloBoss RTU product lines. These products use the ROC protocol for communications between ...

9.8CVSS9.4AI score0.00507EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2022/06/22 12:00 a.m.32 views

PT-2022-3084 · Motorola · Motorola Ace1000 Rtu

Name of the Vulnerable Software and Affected Versions: Motorola ACE1000 RTU through 2022-05-02 Description: The issue is related to the use of hardcoded SSH credentials. This could allow a remote attacker to gain unauthorized access to protected information. The hardcoded SSH private key is likel...

9.8CVSS7.1AI score0.00977EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
added 2022/06/22 12:00 a.m.20 views

PT-2022-3091 · Motorola · Motorola Ace1000 Rtu

Name of the Vulnerable Software and Affected Versions: Motorola ACE1000 RTU versions prior to 2022-05-02 Description: The issue is related to the use of hardcoded credentials in the XRT LAN-to-radio gateway and XNL microcode software of the Motorola ACE1000 RTU. This allows a remote attacker to...

9.8CVSS9.4AI score0.00608EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2022/06/22 12:00 a.m.16 views

PT-2022-3089 · Motorola · Motorola Moscad +1

Name of the Vulnerable Software and Affected Versions: Motorola MOSCAD and ACE line of RTUs through 2022-05-02 Description: The issue concerns the omission of an authentication requirement in the Motorola MOSCAD and ACE line of RTUs. These devices feature IP Gateway modules that allow for...

7.6CVSS7.5AI score0.00777EPSS
SaveExploits0References9
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.29 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Use of Hard-Coded Credentials (CVE-2019-14926)

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard- coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware...

9.8CVSS8.3AI score0.02085EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.25 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Plaintext Storage of a Password (CVE-2019-14929)

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. ...

9.8CVSS8.3AI score0.01936EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.17 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Use of Hard-Coded Credentials (CVE-2019-14930)

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin and mitsadm...

10CVSS8.4AI score0.02343EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.27 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Improper Neutralization of Special Elements Used in an OS Command (CVE-2019-14931)

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's...

10CVSS8.9AI score0.5809EPSS
SaveExploits3References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.24 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Incorrect Default Permissions (CVE-2019-14925)

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world- readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and oth...

6.5CVSS6.5AI score0.0126EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.25 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Improper Neutralization of Input During Web Page Generation (CVE-2019-14928)

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script XSS vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is...

5.4CVSS5.7AI score0.44149EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.26 views

Emerson OSE Exposure of Sensitive Information to an Unauthorized Actor (CVE-2013-0693)

The kernel in ENEA OSE on the Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier performs network-beacon broadcasts, which allows remote attackers to obtain potentially sensitive informati...

10CVSS5.8AI score0.03263EPSS
SaveExploits0References2
Rows per page