Lucene search
+L

823 matches found

Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.26 views

Emerson DL Command Injection (CVE-2013-2810)

Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier allows remote attackers to execute arbitrary commands via a TCP replay attack. This plugin only works with Tenable.ot. Please visit...

10CVSS5.9AI score0.05983EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.23 views

Siemens SICAM MMU, SICAM T, and SICAM SGU Authentication Bypass By Capture-Replay (CVE-2020-10045)

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application. This plugin onl...

8.8CVSS7.8AI score0.01066EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.34 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Improper Access Control (CVE-2019-14927)

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file which contains data such as usernames, passwords, and oth...

7.5CVSS7.4AI score0.41847EPSS
SaveExploits3References4
OSV
OSV
added 2022/01/28 8:15 p.m.10 views

CVE-2021-22816

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334...

7.5CVSS5.8AI score0.00947EPSS
SaveExploits0References1
Prion
Prion
added 2022/01/28 8:15 p.m.16 views

Design/Logic Flaw

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334...

7.8CVSS7.5AI score0.00947EPSS
SaveExploits0References1Affected Software9
CVE
CVE
added 2022/01/28 7:09 p.m.68 views

CVE-2021-22816

The CVE-2021-22816 issue affects Schneider Electric SCADAPack RTUs (models 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E, 357E) running firmware 8.18.1 and earlier. The root cause is an improper check for unusual or exceptional conditions (CWE-754) that can lead to a Denial of Service when the R...

7.8CVSS7.5AI score0.00947EPSS
SaveExploits0References1Affected Software1
Exploit DB
Exploit DB
added 2021/10/18 12:00 a.m.408 views

Mitsubishi Electric & INEA SmartRTU - Source Code Disclosure

Exploit Title: Mitsubishi Electric & INEA SmartRTU - Source Code Disclosure Date: 2021-17-10 Exploit Author: Hamit CİBO Vendor Homepage: https://www.inea.si Software Link: https://www.inea.si/telemetrija-in-m2m-produkti/mertu/ Version: ME RTU Tested on: Windows CVE : CVE-2018-16060 PoC Request GE...

7.5CVSS7.3AI score0.19612EPSS
SaveExploits4
CNVD
CNVD
added 2021/09/15 12:00 a.m.91 views

Vulnerability of the Siemens LOGO! CMR family and SIMATIC RTU 3000 family security feature issues

The LOGO! CMR family is a communication system for monitoring and controlling distributed devices and systems via text messages or e-mail.Siemens SIMATIC RTU3000C is a compact RTU from Siemens, Germany is a low-power remote terminal unit RTU for energy self-sufficiency. A vulnerability in the...

5.4CVSS5.5AI score0.00356EPSS
SaveExploits0References1
ICS
ICS
added 2021/09/14 12:00 a.m.80 views

Siemens LOGO! CMR and SIMATIC RTU 3000

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: LOGO! CMR2020, LOGO! CMR2040 and SIMATIC RTU 3000 family Vulnerabilities: Incorrect Calculation of Buffer Size, Improper Certificate Validation 2. RISK EVALUATION Successful...

7.5CVSS8.7AI score0.0197EPSS
SaveExploits1References5
ICS
ICS
added 2021/09/14 12:00 a.m.86 views

Siemens LOGO! CMR and SIMATIC RTU 3000 (Update A)

1. EXECUTIVE SUMMARY CVSS v3 5.4 ATTENTION: Low attack complexity Vendor: Siemens Equipment: LOGO! CMR, SIMATIC RTU 3000 Vulnerability: Use of Insufficiently Random Values 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-257-13 Siemens LOGO! CMR...

5.4CVSS5.8AI score0.00356EPSS
SaveExploits0References11
ICS
ICS
added 2021/09/09 12:00 a.m.84 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Europe B.V. Equipment: smartRTU and INEA ME-RTU Vulnerabilities: OS Command Injection, Improper Access Control, Cross-site Scripting, Use of Hard-coded Credentials, Unprotected...

10CVSS9.9AI score0.5809EPSS
SaveExploits11References5
ICS
ICS
added 2021/07/13 12:00 a.m.212 views

Schneider Electric Modicon Controllers and Software (Update A)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor : Schneider Electric Equipment : EcoStruxure Control Expert, EcoStruxure Process Expert, SCADAPack RemoteConnect x70, SCADAPack x70 RTUs, and Modicon M580 and M340 control products Vulnerabilities :...

9.1CVSS8.4AI score0.01023EPSS
SaveExploits0References5
OSV
OSV
added 2021/06/11 4:15 p.m.10 views

CVE-2021-22749

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially...

5.3CVSS5.8AI score0.00925EPSS
SaveExploits0References1
Prion
Prion
added 2021/06/11 4:15 p.m.17 views

Design/Logic Flaw

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially...

5CVSS5AI score0.00925EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2021/06/11 3:40 p.m.67 views

CVE-2021-22749

CVE-2021-22749 affects Schneider Electric Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and earlier. A CWE-200 vulnerability allows an unauthenticated remote attacker to cause information disclosure by sending a crafted HTTP request to the module’s web server, leaking current RTU configuration and tele...

5.3CVSS5.1AI score0.00925EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2020/06/26 5:15 p.m.39 views

CVE-2020-10628

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes unencrypted passwords on the network...

7.5CVSS0.00743EPSS
SaveExploits0References1
NVD
NVD
added 2020/06/26 5:15 p.m.41 views

CVE-2020-10624

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes a session token on the network...

7.5CVSS0.00743EPSS
SaveExploits0References1
Prion
Prion
added 2020/06/26 5:15 p.m.21 views

Design/Logic Flaw

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes a session token on the network...

5CVSS7.5AI score0.00743EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2020/06/26 5:15 p.m.16 views

Design/Logic Flaw

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes unencrypted passwords on the network...

5CVSS7.5AI score0.00743EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2020/06/26 4:22 p.m.51 views

CVE-2020-10624

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes a session token on the network...

7.6AI score0.00743EPSS
SaveExploits0References1
Rows per page