4 Medium
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
SINGLE
Confidentiality Impact
PARTIAL
Integrity Impact
NONE
Availability Impact
NONE
AV:N/AC:L/Au:S/C:P/I:N/A:N
6.5 Medium
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
NONE
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.8 Medium
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
30.3%
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world- readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##
include('deprecated_nasl_level.inc');
include('compat.inc');
if (description)
{
script_id(500567);
script_version("1.5");
script_set_attribute(attribute:"plugin_modification_date", value:"2023/11/13");
script_cve_id("CVE-2019-14925");
script_name(english:"Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Incorrect Default Permissions (CVE-2019-14925)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-
readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive
configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-21-252-03");
script_set_attribute(attribute:"see_also", value:"https://www.mogozobo.com/");
script_set_attribute(attribute:"see_also", value:"https://www.mogozobo.com/?p=3593");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:S/C:P/I:N/A:N");
script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-14925");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(276);
script_set_attribute(attribute:"vuln_publication_date", value:"2019/10/28");
script_set_attribute(attribute:"patch_publication_date", value:"2019/10/28");
script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:mitsubishielectric:smartrtu_firmware");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Mitsubishi");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Mitsubishi');
var asset = tenable_ot::assets::get(vendor:'Mitsubishi');
var vuln_cpes = {
"cpe:/o:mitsubishielectric:smartrtu_firmware" :
{"versionEndIncluding" : "3.0", "family" : "MERTU"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Vendor | Product | Version | CPE |
---|---|---|---|
mitsubishielectric | smartrtu_firmware | cpe:/o:mitsubishielectric:smartrtu_firmware |
4 Medium
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
SINGLE
Confidentiality Impact
PARTIAL
Integrity Impact
NONE
Availability Impact
NONE
AV:N/AC:L/Au:S/C:P/I:N/A:N
6.5 Medium
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
NONE
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.8 Medium
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
30.3%