Lucene search

K
nessusThis script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_MITSUBISHI_CVE-2019-14930.NASL
HistoryFeb 07, 2022 - 12:00 a.m.

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Use of Hard-Coded Credentials (CVE-2019-14930)

2022-02-0700:00:00
This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
5

10 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:C/I:C/A:C

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

10 High

AI Score

Confidence

High

0.005 Low

EPSS

Percentile

76.8%

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0.
Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root without supplying a password due to insecure entries in /etc/sudoers on the RTU.)

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500505);
  script_version("1.5");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/11/13");

  script_cve_id("CVE-2019-14930");

  script_name(english:"Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Use of Hard-Coded Credentials (CVE-2019-14930)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0.
Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain
unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root
without supplying a password due to insecure entries in /etc/sudoers on the RTU.)  

This plugin only works with
Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-21-252-03");
  script_set_attribute(attribute:"see_also", value:"https://www.mogozobo.com/");
  script_set_attribute(attribute:"see_also", value:"https://www.mogozobo.com/?p=3593");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-14930");

  script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"true");
  script_cwe_id(798);

  script_set_attribute(attribute:"vuln_publication_date", value:"2019/10/28");
  script_set_attribute(attribute:"patch_publication_date", value:"2019/10/28");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:mitsubishielectric:smartrtu_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Mitsubishi");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Mitsubishi');

var asset = tenable_ot::assets::get(vendor:'Mitsubishi');

var vuln_cpes = {
    "cpe:/o:mitsubishielectric:smartrtu_firmware" :
        {"versionEndIncluding" : "3.0", "family" : "MERTU"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
mitsubishielectricsmartrtu_firmwarecpe:/o:mitsubishielectric:smartrtu_firmware

10 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:C/I:C/A:C

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

10 High

AI Score

Confidence

High

0.005 Low

EPSS

Percentile

76.8%

Related for TENABLE_OT_MITSUBISHI_CVE-2019-14930.NASL