Lucene search
+L

469 matches found

osv_cve
osv_cve
•added 2022/06/14 10:15 a.m.•29 views

CVE-2022-30937

A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...

7.5CVSS7AI score0.01274EPSS
SaveExploits0References1
NVD
NVD
•added 2022/06/14 10:15 a.m.•61 views

CVE-2022-30937

A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...

7.8CVSS0.01274EPSS
SaveExploits0References1
Prion
Prion
•added 2022/06/14 10:15 a.m.•34 views

Memory corruption

A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...

7.8CVSS7.5AI score0.01274EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2022/06/14 9:21 a.m.•112 views

CVE-2022-30937

CVE-2022-30937 affects Siemens EN100 Ethernet Module variants: DNP3 IP, IEC 104, IEC 61850 (all versions prior to 4.37), Modbus TCP, and PROFINET IO. The issue is a memory corruption vulnerability in the HTTP parsing of the /txtrace endpoint, which could crash the affected application and cause a...

7.8CVSS7.4AI score0.01274EPSS
SaveExploits0References1Affected Software5
ICS
ICS
•added 2022/06/14 12:00 a.m.•51 views

Siemens EN100 Ethernet Module

1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: EN100 Ethernet Module Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of this vulnerability could...

7.8CVSS7.8AI score0.01274EPSS
SaveExploits0References11
osv_cve
osv_cve
•added 2022/05/02 7:15 p.m.•20 views

CVE-2022-28613

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The...

7.5CVSS5.8AI score0.0099EPSS
SaveExploits0References2
Prion
Prion
•added 2022/05/02 7:15 p.m.•35 views

Information disclosure

A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an ATTACKER to reboot the device by sending a special crafted message. This issue affects: Hitachi Energy...

7.8CVSS7.3AI score0.0099EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2022/05/02 7:01 p.m.•62 views

CVE-2022-28613 Specially Crafted Modbus TCP Packet Vulnerability in RTU500 series

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The...

7.5CVSS7.5AI score0.0099EPSS
SaveExploits0References1
CVE
CVE
•added 2022/05/02 7:01 p.m.•128 views

CVE-2022-28613

Hitachi Energy RTU500 CMU Firmware versions 12.0.–13.2. are affected by CVE-2022-28613 due to a validation error in the MBAP header length handling in the HCI Modbus TCP function. Exploitation could cause a reboot of the RTU500 CMU when HCI Modbus TCP is enabled, with CVSS v3.1 base score 7.5 (NE...

7.8CVSS7.3AI score0.0099EPSS
SaveExploits0References2Affected Software2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/05/02 12:00 a.m.•6 views

CVE-2022-28613: Improper Validation of Specified Quantity in Input

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The...

7.8CVSS7.2AI score0.0099EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2022/05/02 12:00 a.m.•15 views

PT-2022-2442 · Hitachi Energy · Rtu500 Series Cmu Firmware

Name of the Vulnerable Software and Affected Versions: Hitachi Energy RTU500 series CMU Firmware versions 12.0. through 13.2. Description: A vulnerability exists in the HCI Modbus TCP function, which can be exploited by sending a specially crafted message to the RTU500, causing it to reboot. This...

7.8CVSS6.5AI score0.0099EPSS
SaveExploits0References10
attackerkb
attackerkb
•added 2022/04/19 10:00 a.m.•12 views

CVE-2022-28613

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The...

7.8CVSS7.1AI score0.0099EPSS
SaveExploits0References3Affected Software1
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•81 views

Mitsubishi Electric GOT2000 series and GT SoftGOT2000 (CVE-2021-20592)

Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...

7.7AI score0.01497EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•27 views

Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers Buffer Copy Without Checking Size of Input (CVE-2017-16740)

A Buffer Overflow issue was discovered in Rockwell Automation Allen- Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. This plugin only works with Tenable.ot...

10CVSS8AI score0.07204EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•40 views

Schneider Electric PowerLogic PM55xx and PowerLogic PM8ECC Improper Authentication (CVE-2021-22764)

A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...

5.3CVSS5.8AI score0.01858EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•29 views

Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6845)

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum all firmware versions, which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. This...

7.5CVSS7.4AI score0.01064EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•43 views

Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays Improper Input Validation (CVE-2018-16563)

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...

5.9CVSS6.3AI score0.01155EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•119 views

Siemens EN100 Ethernet module & SIPROTEC Merging Unit Denial of Service (CVE-2015-5374)

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

7.8CVSS7AI score0.74497EPSS
SaveExploits7References7
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•29 views

Schneider Electric Modicon Controllers Improper Check For Unusual or Exceptional Conditions (CVE-2018-7794)

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium see security notification for specific versions which could cause a Denial of Service when reading data with invalid index using Modbus TCP. This...

7.5CVSS7.3AI score0.01399EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•25 views

Siemens SIPROTEC Information Disclosure (CVE-2016-4784)

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS6.7AI score0.02676EPSS
SaveExploits0References7
Rows per page