Siemens SIPROTEC Information Disclosure (CVE-2016-4785)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Schneider Electric PowerLogic PM55xx and PowerLogic PM8ECC Improper Authentication (CVE-2021-22764)
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...
Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays Improper Input Validation (CVE-2018-16563)
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...
Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers Buffer Copy Without Checking Size of Input (CVE-2017-16740)
A Buffer Overflow issue was discovered in Rockwell Automation Allen- Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. This plugin only works with Tenable.ot...
Siemens EN100 Ethernet module & SIPROTEC Merging Unit Denial of Service (CVE-2015-5374)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6845)
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum all firmware versions, which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. This...
Sealevel Systems, Inc. SeaConnect 370W OTA update task file overwrite vulnerability
Summary A file write vulnerability exists in the OTA update task functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. A specially-crafted MQTT payload can lead to arbitrary file overwrite. An attacker can perform a man-in-the-middle attack to trigger this vulnerability. Tested Version...
Sealevel Systems, Inc. SeaConnect 370W Modbus/SeaMAX Remote Configuration denial of service vulnerabilities
Summary Two denial of service vulnerabilities exist in the Modbus/SeaMAX Remote Configuration functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. Specially-crafted network packets can lead to denial of service. An attacker can send a malicious packet to trigger these vulnerabilities...
ECOA Building Automation System - Configuration Download Information Disclosure
Exploit Title: ECOA Building Automation System - Configuration Download Information Disclosure Date: 25.06.2021 Exploit Author: Neurogenesia Vendor Homepage: http://www.ecoa.com.tw ECOA Building Automation System Configuration Download Information Disclosure Vendor: ECOA Technologies Corp. Produc...
ECOA Building Automation System - Directory Traversal Content Disclosure
Exploit Title: ECOA Building Automation System - Directory Traversal Content Disclosure Date: 25.06.2021 Exploit Author: Neurogenesia Vendor Homepage: http://www.ecoa.com.tw ECOA Building Automation System Directory Traversal Content Disclosure Vendor: ECOA Technologies Corp. Product web page:...
ECOA Building Automation System Arbitrary File Deletion Vulnerability
ECOA building automation systems suffer from an arbitrary file deletion vulnerability. Many versions are affected. ECOA Building Automation System Arbitrary File Deletion Vendor: ECOA Technologies Corp. Product web page: http://www.ecoa.com.tw Affected version: ECOA ECS Router Controller - ECS...
ECOA Building Automation System Path Traversal Arbitrary File Upload
Summary 1 The Risk-Terminator Web Graphic control BEMS Building Energy Management System are designed to provide you with the latest in the Human Machine Interface HMI technology, for completely monitoring and controlling management. It may be used singly for small and medium sized facilities,...
CVE-2021-20592
Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...
CVE-2021-20592
Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...
CVE-2021-20592
Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...
Design/Logic Flaw
Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...
CVE-2021-20592
CVE-2021-20592 affects Mitsubishi Electric GOT2000 family: GOT2000 GT27/GT25/GT23 MODBUS/TCP Slave drivers (versions 01.19.000ā01.39.010) and GT SoftGOT2000 (versions 1.170Cā1.256S). Root cause is missing synchronization in the MODBUS/TCP communication path, allowing a remote unauthenticated atta...
CVE-2021-20592
Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...
Unspecified Vulnerability in Siemens Interniche IP Stack Low Voltage Devices
The SENTRON 3WA COM190 is an accessory module for 3WA circuit breakers providing connectivity via PROFINET IO and Modbus TCP.The SENTRON 3WL COM35 is an accessory module for 3WL circuit breakers providing connectivity via PROFINET IO and Modbus TCP.The SENTRON 7KM PAC The Switched Ethernet PROFIN...
CVE-2021-20592: Improper Synchronization
Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...