Lucene search

K
nessusThis script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SCHNEIDER_CVE-2019-6845.NASL
HistoryFeb 07, 2022 - 12:00 a.m.

Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6845)

2022-02-0700:00:00
This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
8

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

0.002 Low

EPSS

Percentile

54.0%

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500304);
  script_version("1.6");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/18");

  script_cve_id("CVE-2019-6845");

  script_name(english:"Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6845)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon
Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring
applications to the controller using Modbus TCP protocol.  

This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
  # https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-281-03
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?9d949489");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:N/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-6845");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(319);

  script_set_attribute(attribute:"vuln_publication_date", value:"2019/10/29");
  script_set_attribute(attribute:"patch_publication_date", value:"2019/10/29");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_series_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/o:schneider-electric:modicon_m580_series_firmware" :
        {"family" : "ModiconM580"},
    "cpe:/o:schneider-electric:modicon_m340_series_firmware" :
        {"family" : "ModiconM340"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
schneider-electricmodicon_m580_series_firmwarecpe:/o:schneider-electric:modicon_m580_series_firmware
schneider-electricmodicon_m340_series_firmwarecpe:/o:schneider-electric:modicon_m340_series_firmware

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

0.002 Low

EPSS

Percentile

54.0%

Related for TENABLE_OT_SCHNEIDER_CVE-2019-6845.NASL