401 matches found
CVE-2022-28613 Specially Crafted Modbus TCP Packet Vulnerability in RTU500 series
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The...
CVE-2022-28613
Hitachi Energy RTU500 CMU Firmware versions 12.0.–13.2. are affected by CVE-2022-28613 due to a validation error in the MBAP header length handling in the HCI Modbus TCP function. Exploitation could cause a reboot of the RTU500 CMU when HCI Modbus TCP is enabled, with CVSS v3.1 base score 7.5 (NE...
PT-2022-2442 · Hitachi Energy · Rtu500 Series Cmu Firmware
Name of the Vulnerable Software and Affected Versions: Hitachi Energy RTU500 series CMU Firmware versions 12.0. through 13.2. Description: A vulnerability exists in the HCI Modbus TCP function, which can be exploited by sending a specially crafted message to the RTU500, causing it to reboot. This...
CVE-2022-28613
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The...
Mitsubishi Electric GOT2000 series and GT SoftGOT2000 (CVE-2021-20592)
Missing synchronization vulnerability in GOT2000 series GT27 model communication driver versions 01.19.000 through 01.39.010, GT25 model communication driver versions 01.19.000 through 01.39.010 and GT23 model communication driver versions 01.19.000 through 01.39.010 and GT SoftGOT2000 versions...
Schneider Electric PowerLogic PM55xx and PowerLogic PM8ECC Improper Authentication (CVE-2021-22764)
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially...
Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays Improper Input Validation (CVE-2018-16563)
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...
Siemens SIPROTEC Information Disclosure (CVE-2016-4784)
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Schneider Electric Modicon Controllers Improper Check For Unusual or Exceptional Conditions (CVE-2019-6857)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium see security notification for specific versions which could cause a Denial of Service of the controller when reading specific memory blocks using...
Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6845)
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum all firmware versions, which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. This...
Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers Buffer Copy Without Checking Size of Input (CVE-2017-16740)
A Buffer Overflow issue was discovered in Rockwell Automation Allen- Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. This plugin only works with Tenable.ot...
Schneider Electric Modicon Controllers Improper Check For Unusual or Exceptional Conditions (CVE-2018-7794)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium see security notification for specific versions which could cause a Denial of Service when reading data with invalid index using Modbus TCP. This...
Siemens SIPROTEC Information Disclosure (CVE-2016-4785)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens EN100 Ethernet module & SIPROTEC Merging Unit Denial of Service (CVE-2015-5374)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens EN100 Ethernet Module Relative Path Traversal (CVE-2019-13944)
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
Sealevel Systems, Inc. SeaConnect 370W Modbus/SeaMAX Remote Configuration denial of service vulnerabilities
Summary Two denial of service vulnerabilities exist in the Modbus/SeaMAX Remote Configuration functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. Specially-crafted network packets can lead to denial of service. An attacker can send a malicious packet to trigger these vulnerabilities...
Sealevel Systems, Inc. SeaConnect 370W OTA update task file overwrite vulnerability
Summary A file write vulnerability exists in the OTA update task functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. A specially-crafted MQTT payload can lead to arbitrary file overwrite. An attacker can perform a man-in-the-middle attack to trigger this vulnerability. Tested Version...
ECOA Building Automation System - Configuration Download Information Disclosure
Exploit Title: ECOA Building Automation System - Configuration Download Information Disclosure Date: 25.06.2021 Exploit Author: Neurogenesia Vendor Homepage: http://www.ecoa.com.tw ECOA Building Automation System Configuration Download Information Disclosure Vendor: ECOA Technologies Corp. Produc...
ECOA Building Automation System - Directory Traversal Content Disclosure
Exploit Title: ECOA Building Automation System - Directory Traversal Content Disclosure Date: 25.06.2021 Exploit Author: Neurogenesia Vendor Homepage: http://www.ecoa.com.tw ECOA Building Automation System Directory Traversal Content Disclosure Vendor: ECOA Technologies Corp. Product web page:...
ECOA Building Automation System Arbitrary File Deletion Vulnerability
ECOA building automation systems suffer from an arbitrary file deletion vulnerability. Many versions are affected. ECOA Building Automation System Arbitrary File Deletion Vendor: ECOA Technologies Corp. Product web page: http://www.ecoa.com.tw Affected version: ECOA ECS Router Controller - ECS...