Advantech WebAccess Vulnerabilities
OVERVIEW This advisory follows up on two previous ICS-CERT Alerts: “ICS-ALERT-11-245-01—Multiple ActiveX Vulnerabilities in Advantech BroadWin WebAccess,” published September 2, 2011.http://ics-cert.us-cert.gov/alerts/ICS-ALERT-11-245-01, ICS-ALERT-11-245-01, website last accessed February 15,...
GE Intelligent Platforms Proficy Real-Time Information Portal Directory Traversal
Overview ICS-CERT received a report from GE Intelligent Platforms and the Zero Day Initiative ZDI. If exploited, this vulnerability could allow an attacker to create or overwrite a file on the system running Real-Time Information Portal. concerning a directory traversal vulnerability in the GE...
GE Intelligent Platforms Proficy Plant Applications Memory Corruption Vulnerabilities
Overview ICS-CERT received a report from GE Intelligent Platforms and the Zero Day Initiative ZDI concerning multiple memory corruption vulnerabilities in the GE Intelligent Platforms Proficy Plant Applications. These vulnerabilities were reported to ZDI by independent security researcher Luigi...
GE Proficy Historian ihDataArchiver
Overview ICS-CERT originally released Advisory ICSA-12-032-01P on the US-CERT secure portal on March 02, 2012. This web page release was delayed to allow users time to download and install the update. ICS-CERT received a report from GE Intelligent Platforms and the Zero Day Initiative ZDI...
Siemens SIMATIC WinCC Vulnerabilities
Overview This advisory is a follow-up to a previous advisory titled “ICSA-11-356-01 – Siemens HMI Authentication Vulnerabilities” that was published December 22, 2011, and an alert titled "ICS-ALERT-11-332-02A – Siemens SIMATIC WinCC Flexible Vulnerabilities" that was published December 2, 2011...
7-Technologies Termis DLL Hijacking
Overview ICS-CERT originally released Advisory ICSA-12-025-02P on the US-CERT secure portal on January 25, 2012. This web page release was delayed to allow users time to download and install the update. Researcher Kuang-Chun Hung of the Security Research and Service Institute−Information and...
Ocean Data Systems Dream Reports XSS and Write Access Violation Vulnerabilities
Overview Independent researchers Billy Rios and Terry McCorkle identified cross-site scripting XSS and write access violation vulnerabilities in Ocean Data Systems Dream Report application. ICS-CERT has coordinated these vulnerabilities with Ocean Data Systems, which has produced a new version th...
MICROSYS PROMOTIC Vulnerabilities
Overview This advisory is a follow-up to ICS-ALERT-11-286-01 - MICROSYS PROMOTIC Vulnerabilities, released to the ICS-CERT Web page on October 12, 2011. Independent researcher Luigi Auriemma has identified and released three vulnerabilities in MICROSYS, spol. s r.o. PROMOTIC application without...
Schneider Electric Quantum Ethernet Module Hard-Coded Credentials
OVERVIEW --------- Begin Update B Part 1 of 3 -------- This updated advisory is a follow-up to the updated advisory titled ICSA-12-018-01A Schneider Electric Quantum Ethernet Module Hard-Coded Credentials that was published on June 04, 2013, on the ICS-CERT Web site. It is also a follow-up to the...
Cogent DataHub XSS and CRLF
Overview ICS-CERT is aware of a public report of multiple vulnerabilities in Cogent’s DataHub application. These vulnerabilities include cross-site scripting and an HTTP header injection vulnerability, also known as a carriage return line feed. According to the report, Cogent Real-Times Systems...
ING. Punzenberger COPA-DATA GMBH DoS Vulnerabilities
Overview ICS-CERT originally released Advisory ICSA-12-013-01P on the US-CERT secure portal on January 13, 2012. This web page release was delayed to allow users time to download and install the update. Researcher Kuang-Chun Hung of the Security Research and Service Institute--Information and...
Open Automation Software OPC Systems.NET Vulnerability
Overview This Advisory is a follow-up to “ICS-ALERT-11-285-01—Open Automation Software OPC Systems.NET Vulnerability” that was posted on the ICS-CERT website on October 12, 2011. Independent researcher Luigi Auriemma publicly reported a malformed packet vulnerability in Open Automation Software’s...
3S CoDeSys Vulnerabilities
Overview This advisory is a follow-up to the alert update, ICS-ALERT-11-336-01A 3S CoDeSys Vulnerabilities, which was released on the ICS-CERT Web page on December 02, 2011. Security researcher Celil Unuver SignalSec LLC and independent researcher Luigi Auriemma have identified vulnerabilities in...
I-GEN opLYNX Central Authentication Bypass
Overview This advisory provides mitigation details for a vulnerability that impacts the i-GEN opLYNX Central software. Exploitation of this vulnerability would allow partial leakage of information and access to system settings. Independent researcher Anthony Cicalla has identified an authenticati...
Carlo Gavazzi EOS Box Multiple Vulnerabilities
Overview This advisory provides mitigation details for multiple vulnerabilities that impact the Carlo Gavazzi EOS-Box Photovoltaic Monitoring System. Carlo Gavazzi has identified two vulnerabilities in the Carlo Gavazzi EOS-Box Photovoltaic Monitoring System. Carlo Gavazzi has produced a firmware...
Ruggedcom ROS Hard-Coded RSA SSL Private Key
Overview This Updated Advisory is a follow-up to the original advisory titled ICSA-12-354-01 RuggedCom ROS Hard-Coded RSA SSL Private Key that was published December 18, 2012, on the ICS-CERT Web page, as a follow-up to the original ICS-CERT alert ICS-ALERT-12-234-01 RuggedCom ROS Key Management...
Siemens ProcessSuite and Invensys Intouch Poorly Encrypted Password File
Overview This advisory provides mitigation details for a vulnerability that impacts Siemens ProcessSuite and Invensys Wonderware InTouch products. Researcher Seth Bromberger of NCI Security, LLC and independent researcher Slade Griffin have identified an insecure password storage vulnerability in...
Rockwell Allen-Bradley MicroLogix, SLC 500, and PLC-5 Fault Generation Vulnerability
OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-12-342-01A Rockwell Allen-Bradley MicroLogix, SLC 500, and PLC-5 controller that was published December 11, 2012, on the NCCIC/ICS-CERT web site. Independent researcher Matthew Luallen of CYBATI has identified a fau...
GE Proficy HMI/SCADA Cimplicity Integer Overflow
OVERVIEW This updated advisory is a follow-up to the original ICS-CERT Advisory titled ICSA-12-341-01P—GE PROFICY HMI/SCADA CIMPLICITY INTEGER OVERFLOW that was published December 06, 2012, to the US-CERT secure Portal library. Researcher Kuang-Chun Hung of Information and Communication Security...
Post Oak Bluetooth Traffic Systems Insufficient Entropy Vulnerability
Overview This advisory provides mitigation details for a vulnerability that impacts Post Oak Traffic AWAM Bluetooth Reader Systems. An independent research group composed of Nadia Heninger University of California at San Diego, J. Alex Halderman, Zakir Durumeric, and Eric Wustrow all from the...
Sinapsi Devices Vulnerabilities
Overview This advisory is a follow-up to the alert titled ICS-ALERT-12-284-01—Sinapsi eSolar Light Vulnerabilities that was published October 10, 2012. Independent researchers Roberto Paleari and Ivan Speziale identified four vulnerabilities and released proof-of-concept exploit code for the...
ABB AC500 PLC Webserver CoDeSys Vulnerability
Overview ICS-CERT has been notified of a buffer overflow vulnerability in the ABB AC500 PLC Webserver application. Successful exploitation of this vulnerability could lead to a denial of service DoS, affecting the availability of the service. This vulnerability is related to ICS-CERT Advisory,...
Siemens SiPass Server Buffer Overflow
OVERVIEW This advisory provides mitigation details provided by Siemens for a vulnerability that impacts the Siemens SiPass server. Siemens has reported a buffer overflow vulnerability in the Siemens SiPass server. Lucas Apa of IOActive discovered this vulnerability and reported it directly to...
Korenix Jetport 5600 Series Hard-coded Credentials
Overview This advisory provides mitigation details for a vulnerability that impacts the Korenix JetPort 5600. Independent researcher Reid Wightman of Digital Bond identified undocumented hard-coded root credentials in the firmware of the Korenix JetPort 5600 system application without coordinatio...
Tropos Wireless Mesh Routers
Overview This advisory is a follow-up to the original advisory titled ICSA-12-297-01P—Tropos Wireless Mesh Routers Insufficient Entropy Vulnerability that was published October 23, 2012, on the ICS-CERT secure Portal library. This advisory provides mitigation details for a vulnerability that...
Siemens S7-1200 Web Application Cross Site Scripting
Overview This advisory provides mitigation details provided by Siemens for a vulnerability that impacts the Siemens S7-1200 Web Application Module. Siemens has reportedSSA-279823, http://www.siemens.com/corporate-technology/en/research-areas/siemens-cert-security-advisories.htm, Web site last...
WellinTech KingView User Credentials Not Securely Hashed
Overview This advisory is a follow-up to the alert titled ICS-ALERT-12-212-02 WellinTech KingView User Credentials Not Securely Hashed that was published July 30, 2012, on the ICS-CERT Web page. Dr. Wesley McGrew of Mississippi State University has identified a default credential vulnerability in...
Optimalog Optima PLC Multiple Vulnerabilities
Overview Independent researcher Luigi Auriemma identified a NULL Pointer Dereference and an Infinite Loop and released proof-of-concept exploit code for Optimalog’s Optima PLC application without coordination with ICS-CERT, the vendor, or any other coordinating entity known to ICS-CERT. Optimalog...
C3-ilex EOScada Multiple Vulnerabilities
Overview This Advisory is a follow-up release to the original Advisory which was posted to the US-CERT secure Portal library October 08, 2012. Dale Peterson of Digital Bond has identified multiple vulnerabilities in the C3-ilex’s EOScada application that can result in data leakage and a...
Emerson DeltaV Buffer Overflow
Overview ICS-CERT originally released Advisory ICSA-12-265-01P on the US-CERT Portal on September 21, 2012. This web page release was delayed to provide the vendor time to contact customers concerning this information. Researcher Kuang-Chun Hung of the Security Research and Service...
Siemens S7-1200 Insecure Storage of HTTPS CA Certificate
Overview Siemens has reportedSSA-240718, http://www.siemens.com/corporate-technology/en/research-areas/siemens-cert-security-advisories.htm, Web site last accessed September 19, 2012 an insecure HTTPS certificate storage vulnerability in Siemens’ S7-1200 v2.x. Siemens has provided guidance to...
ORing Industrial Networking IDS-5042/5042+ Hard-Coded Credential Vulnerability
Overview Independent researcher Reid Wightman of Digital BondKorenix and ORing Use Crypto, http://www.digitalbond.com/2012/06/13/korenix-and-oring-insecurity/, Web site last accessed September 19, 2012. identified hard-coded credentials in the operating system of the ORing Industrial DIN-Rail...
Fultek WinTr Directory Traversal
Overview Researcher Daiki Fukumori of Cyber Defense Institute has identified a directory traversal vulnerability in Fultek’s WinTr SCADA application. Fultek was unable to validate this vulnerability and has not offered any mitigation plans. ICS-CERT has validated the vulnerability. This...
IOServer OPC Server Multiple Vulnerabilities
Overview Independent researcher Hinge of foofus.net has identified multiple vulnerabilitiesIOServer “Root Directory” Trailing Backslash Web Server Vuln, http://www.foofus.net/?pageid=616, Web site last accessed September 13, 2012. in IOServer’s OPC Server application. IOServer has released a new...
Siemens WinCC WebNavigator Multiple Vulnerabilities
Overview Siemens has reported multiple vulnerabilities in the Siemens WinCC WebNavigator application. These vulnerabilities were originally reported directly to Siemens by Positive Technologies. Siemens has produced an update that mitigates these vulnerabilities. These vulnerabilities could be...
RealFlex RealWinDemo DLL Hijack
Overview Independent researcher Carlos Mario Penagos Hollmann has identified an uncontrolled search path element vulnerability, commonly referred to as a DLL hijack, in the RealFlex RealWinDemo application. RealFlex Technologies has produced an upgrade to address this vulnerability, which Mr...
InduSoft ISSymbol ActiveX Control Buffer Overflow
Overview ICS-CERT received a report from Indusoft and the Zero Day Initiative ZDI concerning a heap-based buffer overflow vulnerability affecting the InduSoft ISSymbol ActiveX control. This vulnerability was reported to ZDI by security researcher Alexander Gavrun. Successful exploitation of this...
Arbiter Systems Power Sentinel Denial-of-Service Vulnerability
Overview Arbiter Systems reported to ICS-CERT that a vulnerability that causes a denial of service DoS has been identified in Arbiter Systems Power Sentinel Phasor Measurement Unit. The vulnerability can be exploited remotely. Arbiter Systems has produced a patch that mitigates this vulnerability...
WAGO IO 758 Default Linux Credentials
Overview This advisory updates the ICS-CERT Alert titled “ICS-ALERT-12-097-01 - WAGO IPC Vulnerabilities” that was posted on the ICS-CERT Web site on April 06, 2012. This alert detailed a vulnerability report of “hard-coded” credentials and improper access controls in the WAGO I/O System 758...
GarrettCom - Use of Hard-Coded Password
Overview Independent security researcher Justin W. Clarke of Cylance Inc. has identified a privilege-escalation vulnerability in the GarrettCom Magnum MNS-6K Management Software application via the use of a hard-coded password. This vulnerability could allow a remote attacker with any level of...
GE Intelligent Platforms Proficy Real-Time Information Portal Vulnerabilities
OVERVIEW This advisory is a follow-up to the previously updated portal advisory titled ICSA-12-234-01AP—GE Intelligent Platforms Proficy Real-Time Information Portal Multiple Vulnerabilities, which was published September 17, 2012, in the US-CERT secure Portal library. This advisory provides...
Tridium Niagara Vulnerabilities
OVERVIEW --------- Begin Update A Part 1 of 2 -------- This updated advisory is a follow-up to the original advisory titled ICSA-12-228-01 Tridium Niagara Multiple Vulnerabilities that was published August 15, 2012, on the ICS-CERT Web page. It is also a follow-up to ICS-ALERT-12-195-01 Tridium...
Siemens COMOS Database Privilege Escalation Vulnerability
Overview Siemens has reported a privilege escalation vulnerability in the Siemens COMOS database application. Siemens has produced an update that fixes this vulnerability. This vulnerability could be exploited remotely. Affected Products Siemens reports that the vulnerability affects the followin...
Siemens Synco OZW Default Password
Overview Siemens has reported to ICS-CERT that a default password vulnerability exists in the Siemens Synco OZW Web Server device used for building automation systems. Siemens urges their customers to set a secure password on their device’s web interface. This vulnerability could be exploited...
Sielco Sistemi Winlog Multiple Vulnerabilities
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-12-213-01 - Sielco Sistemi Winlog Multiple Vulnerabilities that was published July 31, 2012, on the NCCIC/ICS-CERT web site. The updated advisory matches new CVE identifiers up with other publicly available...
Siemens SIMATIC S7-400 PN CPU DoS
Overview Siemens has reported to ICS-CERT that denial-of-service DoS vulnerabilities exist in the SIMATIC S7-400 V6 and SIMATIC S7-400 V5 PN CPU products. Siemens has produced a firmware update that mitigates the vulnerability affecting the S7-400 V6. Siemens will not fix the vulnerability that...
ICONICS GENESIS32/BizViz Security Configurator Authentication Bypass Vulnerability
Overview Dr. Wesley McGrew of Mississippi State University has identified an authentication bypass vulnerability leading to privilege escalation in the ICONICS GENESIS32 and BizViz applications, specifically in the Security Configurator component. This vulnerability allows an attacker to bypass...
Siemens SIMATIC STEP 7 DLL Vulnerability
Overview Siemens has released a software update for a DLL hijacking vulnerability in SIMATIC STEP 7 and SIMATIC PCS 7 software. Previous versions of SIMATIC STEP 7 and PCS 7 allowed the loading of malicious DLL files into the STEP 7 project folder that can be used to attack the system on which ST...
Siemens WinCC Insecure SQL Server Authentication
Overview Siemens has released a software update for an insecure SQL server authentication vulnerability in Siemens’ SIMATIC WinCC and SIMATIC PCS 7 software. Previous versions of SIMATIC WinCC use default SQL server credentials that allowed administrative access to the database. The default...
OSIsoft PI OPC DA Interface Buffer Overflow
Overview ICS-CERT has received a report from OSIsoft concerning a stack-based buffer overflow in the PI OPC DA Interface software that could cause the software to crash or allow a remote attacker to execute arbitrary code. This vulnerability was discovered during a software assessment requested b...