added 2012/11/19 7:00 a.m.84 views

Advantech WebAccess Vulnerabilities

OVERVIEW This advisory follows up on two previous ICS-CERT Alerts: “ICS-ALERT-11-245-01—Multiple ActiveX Vulnerabilities in Advantech BroadWin WebAccess,” published September 2, 2011.http://ics-cert.us-cert.gov/alerts/ICS-ALERT-11-245-01, ICS-ALERT-11-245-01, website last accessed February 15,...

10CVSS8.5AI score0.04305EPSS
SaveExploits0References10
ICS
ICS
added 2012/11/04 6:00 a.m.44 views

GE Intelligent Platforms Proficy Real-Time Information Portal Directory Traversal

Overview ICS-CERT received a report from GE Intelligent Platforms and the Zero Day Initiative ZDI. If exploited, this vulnerability could allow an attacker to create or overwrite a file on the system running Real-Time Information Portal. concerning a directory traversal vulnerability in the GE...

6.4CVSS6.5AI score0.02209EPSS
SaveExploits0References10
ICS
ICS
added 2012/11/04 6:00 a.m.57 views

GE Intelligent Platforms Proficy Plant Applications Memory Corruption Vulnerabilities

Overview ICS-CERT received a report from GE Intelligent Platforms and the Zero Day Initiative ZDI concerning multiple memory corruption vulnerabilities in the GE Intelligent Platforms Proficy Plant Applications. These vulnerabilities were reported to ZDI by independent security researcher Luigi...

10CVSS7.7AI score0.09164EPSS
SaveExploits0References10
ICS
ICS
added 2012/11/04 6:00 a.m.67 views

GE Proficy Historian ihDataArchiver

Overview ICS-CERT originally released Advisory ICSA-12-032-01P on the US-CERT secure portal on March 02, 2012. This web page release was delayed to allow users time to download and install the update. ICS-CERT received a report from GE Intelligent Platforms and the Zero Day Initiative ZDI...

10CVSS7.4AI score0.04953EPSS
SaveExploits0References10
ICS
ICS
added 2012/11/02 6:00 a.m.122 views

Siemens SIMATIC WinCC Vulnerabilities

Overview This advisory is a follow-up to a previous advisory titled “ICSA-11-356-01 – Siemens HMI Authentication Vulnerabilities” that was published December 22, 2011, and an alert titled "ICS-ALERT-11-332-02A – Siemens SIMATIC WinCC Flexible Vulnerabilities" that was published December 2, 2011...

10CVSS8.5AI score0.14013EPSS
SaveExploits1References10
ICS
ICS
added 2012/10/28 6:00 a.m.40 views

7-Technologies Termis DLL Hijacking

Overview ICS-CERT originally released Advisory ICSA-12-025-02P on the US-CERT secure portal on January 25, 2012. This web page release was delayed to allow users time to download and install the update. Researcher Kuang-Chun Hung of the Security Research and Service Institute−Information and...

9.3CVSS6.7AI score0.01787EPSS
SaveExploits0References10
ICS
ICS
added 2012/10/27 6:00 a.m.45 views

Ocean Data Systems Dream Reports XSS and Write Access Violation Vulnerabilities

Overview Independent researchers Billy Rios and Terry McCorkle identified cross-site scripting XSS and write access violation vulnerabilities in Ocean Data Systems Dream Report application. ICS-CERT has coordinated these vulnerabilities with Ocean Data Systems, which has produced a new version th...

9.3CVSS6.9AI score0.04282EPSS
SaveExploits0References10
ICS
ICS
added 2012/10/27 6:00 a.m.48 views

MICROSYS PROMOTIC Vulnerabilities

Overview This advisory is a follow-up to ICS-ALERT-11-286-01 - MICROSYS PROMOTIC Vulnerabilities, released to the ICS-CERT Web page on October 12, 2011. Independent researcher Luigi Auriemma has identified and released three vulnerabilities in MICROSYS, spol. s r.o. PROMOTIC application without...

5CVSS7AI score0.26385EPSS
SaveExploits1References10
ICS
ICS
added 2012/10/21 6:00 a.m.76 views

Schneider Electric Quantum Ethernet Module Hard-Coded Credentials

OVERVIEW --------- Begin Update B Part 1 of 3 -------- This updated advisory is a follow-up to the updated advisory titled ICSA-12-018-01A Schneider Electric Quantum Ethernet Module Hard-Coded Credentials that was published on June 04, 2013, on the ICS-CERT Web site. It is also a follow-up to the...

10CVSS7.8AI score0.03894EPSS
SaveExploits1References10
ICS
ICS
added 2012/10/19 6:00 a.m.38 views

Cogent DataHub XSS and CRLF

Overview ICS-CERT is aware of a public report of multiple vulnerabilities in Cogent’s DataHub application. These vulnerabilities include cross-site scripting and an HTTP header injection vulnerability, also known as a carriage return line feed. According to the report, Cogent Real-Times Systems...

5.8CVSS6.9AI score0.01457EPSS
SaveExploits0References10
ICS
ICS
added 2012/10/16 6:00 a.m.69 views

ING. Punzenberger COPA-DATA GMBH DoS Vulnerabilities

Overview ICS-CERT originally released Advisory ICSA-12-013-01P on the US-CERT secure portal on January 13, 2012. This web page release was delayed to allow users time to download and install the update. Researcher Kuang-Chun Hung of the Security Research and Service Institute--Information and...

7.5CVSS7.8AI score0.03044EPSS
SaveExploits0References10
ICS
ICS
added 2012/10/15 6:00 a.m.35 views

Open Automation Software OPC Systems.NET Vulnerability

Overview This Advisory is a follow-up to “ICS-ALERT-11-285-01—Open Automation Software OPC Systems.NET Vulnerability” that was posted on the ICS-CERT website on October 12, 2011. Independent researcher Luigi Auriemma publicly reported a malformed packet vulnerability in Open Automation Software’s...

7AI score
SaveExploits0References10
ICS
ICS
added 2012/10/09 6:00 a.m.66 views

3S CoDeSys Vulnerabilities

Overview This advisory is a follow-up to the alert update, ICS-ALERT-11-336-01A 3S CoDeSys Vulnerabilities, which was released on the ICS-CERT Web page on December 02, 2011. Security researcher Celil Unuver SignalSec LLC and independent researcher Luigi Auriemma have identified vulnerabilities in...

10CVSS7.6AI score0.72714EPSS
SaveExploits12References10
ICS
ICS
added 2012/09/30 6:00 a.m.68 views

I-GEN opLYNX Central Authentication Bypass

Overview This advisory provides mitigation details for a vulnerability that impacts the i-GEN opLYNX Central software. Exploitation of this vulnerability would allow partial leakage of information and access to system settings. Independent researcher Anthony Cicalla has identified an authenticati...

7.5CVSS6.4AI score0.01646EPSS
SaveExploits0References10
ICS
ICS
added 2012/09/22 6:00 a.m.81 views

Carlo Gavazzi EOS Box Multiple Vulnerabilities

Overview This advisory provides mitigation details for multiple vulnerabilities that impact the Carlo Gavazzi EOS-Box Photovoltaic Monitoring System. Carlo Gavazzi has identified two vulnerabilities in the Carlo Gavazzi EOS-Box Photovoltaic Monitoring System. Carlo Gavazzi has produced a firmware...

10CVSS7.6AI score0.01533EPSS
SaveExploits0References10
ICS
ICS
added 2012/09/22 6:00 a.m.69 views

Ruggedcom ROS Hard-Coded RSA SSL Private Key

Overview This Updated Advisory is a follow-up to the original advisory titled ICSA-12-354-01 RuggedCom ROS Hard-Coded RSA SSL Private Key that was published December 18, 2012, on the ICS-CERT Web page, as a follow-up to the original ICS-CERT alert ICS-ALERT-12-234-01 RuggedCom ROS Key Management...

4.3CVSS6.2AI score0.01134EPSS
SaveExploits0References10
ICS
ICS
added 2012/09/16 6:00 a.m.61 views

Siemens ProcessSuite and Invensys Intouch Poorly Encrypted Password File

Overview This advisory provides mitigation details for a vulnerability that impacts Siemens ProcessSuite and Invensys Wonderware InTouch products. Researcher Seth Bromberger of NCI Security, LLC and independent researcher Slade Griffin have identified an insecure password storage vulnerability in...

1.9CVSS6.2AI score0.00228EPSS
SaveExploits0References10
ICS
ICS
added 2012/09/10 6:00 a.m.103 views

Rockwell Allen-Bradley MicroLogix, SLC 500, and PLC-5 Fault Generation Vulnerability

OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-12-342-01A Rockwell Allen-Bradley MicroLogix, SLC 500, and PLC-5 controller that was published December 11, 2012, on the NCCIC/ICS-CERT web site. Independent researcher Matthew Luallen of CYBATI has identified a fau...

7.1CVSS6.6AI score0.0405EPSS
SaveExploits0References10
ICS
ICS
added 2012/09/09 6:00 a.m.62 views

GE Proficy HMI/SCADA Cimplicity Integer Overflow

OVERVIEW This updated advisory is a follow-up to the original ICS-CERT Advisory titled ICSA-12-341-01P—GE PROFICY HMI/SCADA CIMPLICITY INTEGER OVERFLOW that was published December 06, 2012, to the US-CERT secure Portal library. Researcher Kuang-Chun Hung of Information and Communication Security...

4.3CVSS6.7AI score0.01151EPSS
SaveExploits0References10
ICS
ICS
added 2012/09/03 6:00 a.m.51 views

Post Oak Bluetooth Traffic Systems Insufficient Entropy Vulnerability

Overview This advisory provides mitigation details for a vulnerability that impacts Post Oak Traffic AWAM Bluetooth Reader Systems. An independent research group composed of Nadia Heninger University of California at San Diego, J. Alex Halderman, Zakir Durumeric, and Eric Wustrow all from the...

7.6CVSS6.7AI score0.01547EPSS
SaveExploits0References10
ICS
ICS
added 2012/08/24 6:00 a.m.60 views

Sinapsi Devices Vulnerabilities

Overview This advisory is a follow-up to the alert titled ICS-ALERT-12-284-01—Sinapsi eSolar Light Vulnerabilities that was published October 10, 2012. Independent researchers Roberto Paleari and Ivan Speziale identified four vulnerabilities and released proof-of-concept exploit code for the...

10CVSS7.8AI score0.12079EPSS
SaveExploits3References10
ICS
ICS
added 2012/08/19 6:00 a.m.68 views

ABB AC500 PLC Webserver CoDeSys Vulnerability

Overview ICS-CERT has been notified of a buffer overflow vulnerability in the ABB AC500 PLC Webserver application. Successful exploitation of this vulnerability could lead to a denial of service DoS, affecting the availability of the service. This vulnerability is related to ICS-CERT Advisory,...

10CVSS7.1AI score0.72714EPSS
SaveExploits8References10
ICS
ICS
added 2012/08/04 6:00 a.m.59 views

Siemens SiPass Server Buffer Overflow

OVERVIEW This advisory provides mitigation details provided by Siemens for a vulnerability that impacts the Siemens SiPass server. Siemens has reported a buffer overflow vulnerability in the Siemens SiPass server. Lucas Apa of IOActive discovered this vulnerability and reported it directly to...

10CVSS8.2AI score0.15788EPSS
SaveExploits1References10
ICS
ICS
added 2012/07/27 6:00 a.m.62 views

Korenix Jetport 5600 Series Hard-coded Credentials

Overview This advisory provides mitigation details for a vulnerability that impacts the Korenix JetPort 5600. Independent researcher Reid Wightman of Digital Bond identified undocumented hard-coded root credentials in the firmware of the Korenix JetPort 5600 system application without coordinatio...

10CVSS6.5AI score0.03602EPSS
SaveExploits0References10
ICS
ICS
added 2012/07/27 6:00 a.m.66 views

Tropos Wireless Mesh Routers

Overview This advisory is a follow-up to the original advisory titled ICSA-12-297-01P—Tropos Wireless Mesh Routers Insufficient Entropy Vulnerability that was published October 23, 2012, on the ICS-CERT secure Portal library. This advisory provides mitigation details for a vulnerability that...

6.1CVSS6.7AI score0.00994EPSS
SaveExploits0References10
ICS
ICS
added 2012/07/13 6:00 a.m.54 views

Siemens S7-1200 Web Application Cross Site Scripting

Overview This advisory provides mitigation details provided by Siemens for a vulnerability that impacts the Siemens S7-1200 Web Application Module. Siemens has reportedSSA-279823, http://www.siemens.com/corporate-technology/en/research-areas/siemens-cert-security-advisories.htm, Web site last...

4.3CVSS6.1AI score0.02556EPSS
SaveExploits1References10
ICS
ICS
added 2012/07/13 6:00 a.m.68 views

WellinTech KingView User Credentials Not Securely Hashed

Overview This advisory is a follow-up to the alert titled ICS-ALERT-12-212-02 WellinTech KingView User Credentials Not Securely Hashed that was published July 30, 2012, on the ICS-CERT Web page. Dr. Wesley McGrew of Mississippi State University has identified a default credential vulnerability in...

2.1CVSS6.1AI score0.00322EPSS
SaveExploits0References10
ICS
ICS
added 2012/07/01 6:00 a.m.39 views

Optimalog Optima PLC Multiple Vulnerabilities

Overview Independent researcher Luigi Auriemma identified a NULL Pointer Dereference and an Infinite Loop and released proof-of-concept exploit code for Optimalog’s Optima PLC application without coordination with ICS-CERT, the vendor, or any other coordinating entity known to ICS-CERT. Optimalog...

7.8CVSS6.9AI score0.06722EPSS
SaveExploits1References10
ICS
ICS
added 2012/07/01 6:00 a.m.58 views

C3-ilex EOScada Multiple Vulnerabilities

Overview This Advisory is a follow-up release to the original Advisory which was posted to the US-CERT secure Portal library October 08, 2012. Dale Peterson of Digital Bond has identified multiple vulnerabilities in the C3-ilex’s EOScada application that can result in data leakage and a...

7.8CVSS6.5AI score0.02201EPSS
SaveExploits0References10
ICS
ICS
added 2012/06/25 6:00 a.m.44 views

Emerson DeltaV Buffer Overflow

Overview ICS-CERT originally released Advisory ICSA-12-265-01P on the US-CERT Portal on September 21, 2012. This web page release was delayed to provide the vendor time to contact customers concerning this information. Researcher Kuang-Chun Hung of the Security Research and Service...

5CVSS6.4AI score0.02194EPSS
SaveExploits0References10
ICS
ICS
added 2012/06/23 6:00 a.m.51 views

Siemens S7-1200 Insecure Storage of HTTPS CA Certificate

Overview Siemens has reportedSSA-240718, http://www.siemens.com/corporate-technology/en/research-areas/siemens-cert-security-advisories.htm, Web site last accessed September 19, 2012 an insecure HTTPS certificate storage vulnerability in Siemens’ S7-1200 v2.x. Siemens has provided guidance to...

4.3CVSS6.2AI score0.01472EPSS
SaveExploits1References10
ICS
ICS
added 2012/06/23 6:00 a.m.50 views

ORing Industrial Networking IDS-5042/5042+ Hard-Coded Credential Vulnerability

Overview Independent researcher Reid Wightman of Digital BondKorenix and ORing Use Crypto, http://www.digitalbond.com/2012/06/13/korenix-and-oring-insecurity/, Web site last accessed September 19, 2012. identified hard-coded credentials in the operating system of the ORing Industrial DIN-Rail...

10CVSS6.6AI score0.03602EPSS
SaveExploits0References10
ICS
ICS
added 2012/06/22 6:00 a.m.38 views

Fultek WinTr Directory Traversal

Overview Researcher Daiki Fukumori of Cyber Defense Institute has identified a directory traversal vulnerability in Fultek’s WinTr SCADA application. Fultek was unable to validate this vulnerability and has not offered any mitigation plans. ICS-CERT has validated the vulnerability. This...

7.8CVSS6.5AI score0.02627EPSS
SaveExploits0References10
ICS
ICS
added 2012/06/18 6:00 a.m.35 views

IOServer OPC Server Multiple Vulnerabilities

Overview Independent researcher Hinge of foofus.net has identified multiple vulnerabilitiesIOServer “Root Directory” Trailing Backslash Web Server Vuln, http://www.foofus.net/?pageid=616, Web site last accessed September 13, 2012. in IOServer’s OPC Server application. IOServer has released a new...

4.3CVSS6.7AI score0.02746EPSS
SaveExploits1References10
ICS
ICS
added 2012/06/16 6:00 a.m.105 views

Siemens WinCC WebNavigator Multiple Vulnerabilities

Overview Siemens has reported multiple vulnerabilities in the Siemens WinCC WebNavigator application. These vulnerabilities were originally reported directly to Siemens by Positive Technologies. Siemens has produced an update that mitigates these vulnerabilities. These vulnerabilities could be...

7.5CVSS7.9AI score0.02638EPSS
SaveExploits0References10
ICS
ICS
added 2012/06/11 6:00 a.m.38 views

RealFlex RealWinDemo DLL Hijack

Overview Independent researcher Carlos Mario Penagos Hollmann has identified an uncontrolled search path element vulnerability, commonly referred to as a DLL hijack, in the RealFlex RealWinDemo application. RealFlex Technologies has produced an upgrade to address this vulnerability, which Mr...

6.9CVSS6.7AI score0.00447EPSS
SaveExploits0References10
ICS
ICS
added 2012/06/09 6:00 a.m.77 views

InduSoft ISSymbol ActiveX Control Buffer Overflow

Overview ICS-CERT received a report from Indusoft and the Zero Day Initiative ZDI concerning a heap-based buffer overflow vulnerability affecting the InduSoft ISSymbol ActiveX control. This vulnerability was reported to ZDI by security researcher Alexander Gavrun. Successful exploitation of this...

9.3CVSS7.4AI score0.32349EPSS
SaveExploits12References10
ICS
ICS
added 2012/06/09 6:00 a.m.49 views

Arbiter Systems Power Sentinel Denial-of-Service Vulnerability

Overview Arbiter Systems reported to ICS-CERT that a vulnerability that causes a denial of service DoS has been identified in Arbiter Systems Power Sentinel Phasor Measurement Unit. The vulnerability can be exploited remotely. Arbiter Systems has produced a patch that mitigates this vulnerability...

7.8CVSS6.8AI score0.0147EPSS
SaveExploits0References10
ICS
ICS
added 2012/06/09 6:00 a.m.57 views

WAGO IO 758 Default Linux Credentials

Overview This advisory updates the ICS-CERT Alert titled “ICS-ALERT-12-097-01 - WAGO IPC Vulnerabilities” that was posted on the ICS-CERT Web site on April 06, 2012. This alert detailed a vulnerability report of “hard-coded” credentials and improper access controls in the WAGO I/O System 758...

10CVSS7.8AI score0.03153EPSS
SaveExploits0References10
ICS
ICS
added 2012/06/03 6:00 a.m.41 views

GarrettCom - Use of Hard-Coded Password

Overview Independent security researcher Justin W. Clarke of Cylance Inc. has identified a privilege-escalation vulnerability in the GarrettCom Magnum MNS-6K Management Software application via the use of a hard-coded password. This vulnerability could allow a remote attacker with any level of...

7.7CVSS7.3AI score0.00433EPSS
SaveExploits0References10
ICS
ICS
added 2012/05/25 6:00 a.m.64 views

GE Intelligent Platforms Proficy Real-Time Information Portal Vulnerabilities

OVERVIEW This advisory is a follow-up to the previously updated portal advisory titled ICSA-12-234-01AP—GE Intelligent Platforms Proficy Real-Time Information Portal Multiple Vulnerabilities, which was published September 17, 2012, in the US-CERT secure Portal library. This advisory provides...

7.7AI score
SaveExploits0References10
ICS
ICS
added 2012/05/19 6:00 a.m.59 views

Tridium Niagara Vulnerabilities

OVERVIEW --------- Begin Update A Part 1 of 2 -------- This updated advisory is a follow-up to the original advisory titled ICSA-12-228-01 Tridium Niagara Multiple Vulnerabilities that was published August 15, 2012, on the ICS-CERT Web page. It is also a follow-up to ICS-ALERT-12-195-01 Tridium...

5CVSS6.8AI score0.02542EPSS
SaveExploits0References10
ICS
ICS
added 2012/05/18 6:00 a.m.51 views

Siemens COMOS Database Privilege Escalation Vulnerability

Overview Siemens has reported a privilege escalation vulnerability in the Siemens COMOS database application. Siemens has produced an update that fixes this vulnerability. This vulnerability could be exploited remotely. Affected Products Siemens reports that the vulnerability affects the followin...

8.5CVSS6.9AI score0.02149EPSS
SaveExploits0References10
ICS
ICS
added 2012/05/05 6:00 a.m.366 views

Siemens Synco OZW Default Password

Overview Siemens has reported to ICS-CERT that a default password vulnerability exists in the Siemens Synco OZW Web Server device used for building automation systems. Siemens urges their customers to set a secure password on their device’s web interface. This vulnerability could be exploited...

7.5CVSS6.8AI score0.01443EPSS
SaveExploits0References10
ICS
ICS
added 2012/05/04 6:00 a.m.77 views

Sielco Sistemi Winlog Multiple Vulnerabilities

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-12-213-01 - Sielco Sistemi Winlog Multiple Vulnerabilities that was published July 31, 2012, on the NCCIC/ICS-CERT web site. The updated advisory matches new CVE identifiers up with other publicly available...

9.3CVSS7.8AI score0.44189EPSS
SaveExploits11References10
ICS
ICS
added 2012/05/03 6:00 a.m.54 views

Siemens SIMATIC S7-400 PN CPU DoS

Overview Siemens has reported to ICS-CERT that denial-of-service DoS vulnerabilities exist in the SIMATIC S7-400 V6 and SIMATIC S7-400 V5 PN CPU products. Siemens has produced a firmware update that mitigates the vulnerability affecting the S7-400 V6. Siemens will not fix the vulnerability that...

7.8CVSS6.8AI score0.03464EPSS
SaveExploits0References10
ICS
ICS
added 2012/05/03 6:00 a.m.60 views

ICONICS GENESIS32/BizViz Security Configurator Authentication Bypass Vulnerability

Overview Dr. Wesley McGrew of Mississippi State University has identified an authentication bypass vulnerability leading to privilege escalation in the ICONICS GENESIS32 and BizViz applications, specifically in the Security Configurator component. This vulnerability allows an attacker to bypass...

4.4CVSS6.9AI score0.0021EPSS
SaveExploits0References10
ICS
ICS
added 2012/04/26 6:00 a.m.73 views

Siemens SIMATIC STEP 7 DLL Vulnerability

Overview Siemens has released a software update for a DLL hijacking vulnerability in SIMATIC STEP 7 and SIMATIC PCS 7 software. Previous versions of SIMATIC STEP 7 and PCS 7 allowed the loading of malicious DLL files into the STEP 7 project folder that can be used to attack the system on which ST...

6.9CVSS7.5AI score0.00455EPSS
SaveExploits0References10
ICS
ICS
added 2012/04/26 6:00 a.m.124 views

Siemens WinCC Insecure SQL Server Authentication

Overview Siemens has released a software update for an insecure SQL server authentication vulnerability in Siemens’ SIMATIC WinCC and SIMATIC PCS 7 software. Previous versions of SIMATIC WinCC use default SQL server credentials that allowed administrative access to the database. The default...

7.8CVSS8.2AI score0.0055EPSS
SaveExploits2References10
ICS
ICS
added 2012/04/22 6:00 a.m.46 views

OSIsoft PI OPC DA Interface Buffer Overflow

Overview ICS-CERT has received a report from OSIsoft concerning a stack-based buffer overflow in the PI OPC DA Interface software that could cause the software to crash or allow a remote attacker to execute arbitrary code. This vulnerability was discovered during a software assessment requested b...

8.5CVSS7.8AI score0.04683EPSS
SaveExploits0References10