4376 matches found
Siemens WinCC TIA Portal Vulnerabilities
Overview This advisory provides mitigation details for a vulnerability that impacts the Siemens WinCC TIA Totally Integrated Automation Portal HMI. Researchers Billy Rios and Terry McCorkle of Cylance; Gleb Gritsai, Sergey Bobrov, Roman Ilin, Artem Chaykin, Timur Yunusov, and Ilya Karpov from...
Siemens WinCC 7.0 SP3 Multiple Vulnerabilities
Overview This advisory provides mitigation details for vulnerabilities that impact the Siemens SIMATIC WinCC. Positive Technologies and Siemens ProductCERT have identified multiple vulnerabilities in the Siemens SIMATIC WinCC, which is used to configure SIMATIC operator devices. Siemens has...
Schweitzer Engineering Laboratories AcSELerator Improper Authorization Vulnerability
Overview This advisory provides mitigation details for a vulnerability affecting the Schweitzer Engineering Laboratories SEL AcSELerator QuickSet software. Independent researcher Michael Toecker of Digital Bond has identified an improper authorization vulnerability in the SEL AcSELerator...
Schneider Electric PLCs Vulnerabilities
OVERVIEW --------- Begin Update B Part 1 of 2 -------- This updated advisory is a follow-up to the previous advisory update titled ICSA-13-077-01A Schneider Electric PLCs Vulnerabilities Update A that was published March 20, 2013, on the ICS-CERT Web page. It is also a follow-up to the updated...
InduSoft Advantech Studio Directory Traversal
OVERVIEW This advisory is a follow-up to the alert titled ICS-ALERT-13-004-01—Advantech Studio Directory Traversal that was published January 4, 2013, on the ICS-CERT Web page. Independent researcher Nin3 released proof-of-concept PoC exploit code for a directory traversal vulnerability in Induso...
Invensys Wonderware Win-XML Exporter Improper Input Validation Vulnerability
Overview This advisory was originally posted to the US-CERT secure Portal library on March 08, 2013, and is now being released to the ICS-CERT Web page. This advisory provides mitigation details for a vulnerability that impacts the Invensys Wonderware Win-XML Exporter. Researchers Timur Yunusov,...
Emerson DeltaV Uncontroller Resource Consumption Vulnerability
Overview This advisory was originally posted to the US-CERT secure portal library on February 22, 2013, and is now being released to the ICS-CERT Web page. This advisory provides mitigation details for a vulnerability that impacts the Emerson DeltaV MD and SD controllers. Independent researcher...
Honeywell EBI, SymmetrE, and ComfortPoint Open Manager Station
Overview This updated advisory is a follow-up to the original advisory titled ICSA-13-053-02--Honeywell Enterprise Buildings Integrator EBI, SymmetrE, and ComfortPoint Open Manager Station that was published February 22, 2013, on the ICS-CERT Web page. This advisory provides mitigation details fo...
3S CODESYS Gateway-Server Vulnerabilities
Overview This updated advisory is a follow-up to the original advisory titled ICSA-13-050-01, 3S CODESYS Gateway-Server Vulnerabilities that was published February 19, 2013, on the ICS-CERT Web page. This updated advisory provides mitigation details for five vulnerabilities in the 3S-Smart Softwa...
Tridium NiagaraAX Directory Traversal Vulnerability
Overview This advisory provides mitigation details for a vulnerability in the Tridium NiagaraAX software. Independent researchers Billy Rios and Terry McCorkle discovered a directory traversal vulnerability in the Tridium NiagaraAX software product. They demonstrated that with a valid user accoun...
Schneider Electric Accutech Manager Heap Overflow
Overview This advisory provides mitigation details for a vulnerability that impacts the Schneider Electric Accutech Manager. Independent researcher Aaron Portnoy of Exodus Intelligence has identified a heap-based buffer overflow vulnerability in Schneider Electric’s Accutech Manager application...
WellinTech KingView KingMess Buffer Overflow
Overview This updated advisory is a follow-up to the original advisory titled ICSA-13-043-02—WellinTech KingView KingMess Buffer Overflow that was published February 12, 2013, on the ICS-CERT Web page. This updated advisory provides mitigation details for a vulnerability that impacts the WellinTe...
MOXA EDR-G903 Series Multiple Vulnerabilities
OVERVIEW This advisory provides mitigation details for vulnerabilities that impact Moxa EDR-G903 Series Routers. Independent researcher Neil Smith identified a hard-coded user account vulnerability and an insufficient entropy vulnerability in Moxa’s EDR-G903 series routers. By impersonating the...
360 Systems Image Server 2000 Series Remote Root Access
Overview This updated advisory is a follow-up to the original advisory titled ICSA-13-038-01—360 Systems Image Server 2000 Series Remote Root Access that was published March 06, 2013, on the ICS-CERT Web site. This advisory provides mitigation details for a vulnerability that impacts the 360...
Ecava IntegraXor ActiveX Buffer Overflow
Overview This advisory provides mitigation details for a vulnerability that impacts the Ecava IntegraXor application. Independent researcher Andrew Brooks has identified a buffer overflow vulnerability in Ecava’s IntegraXor application. Ecava has produced a patch that mitigates this vulnerability...
InduSoft ISSymbol ActiveX Control Buffer Overflow (Update A)
Overview Security researcher Dmitriy Pletnevo of Secunia ResearchSecunia Research, http://secunia.com/secuniaresearch/2011-36/, website last accessed June 16, 2011. has released details of multiple overflow vulnerabilities affecting the InduSoft ISSymbol ActiveX control. The researcher identified...
GE Proficy Real-Time Information Portal Information Disclosure Vulnerabilities
Overview This advisory provides mitigation details for multiple vulnerabilities that impact the GE Intelligent Platforms Proficy Real-Time Information Portal. General Electric GE has addressed two vulnerabilities in the GE Intelligent Platforms Proficy Real-Time Information Portal. Exploitation o...
GE Intelligent Platforms Proficy Cimplicity Multiple Vulnerabilities
Overview This advisory provides mitigation details for multiple vulnerabilities that impact GE Intelligent Platforms Proficy HMI/SCADA—CIMPLICITY. General Electric GE has addressed two vulnerabilities in GE Intelligent Platforms Proficy HMI/SCADA—CIMPLICITY: a directory transversal vulnerability...
Schneider Electric IGSS Buffer Overflow
Overview Independent researcher Aaron Portnoy of Exodus Intelligence has identified a buffer overflow vulnerability in Schneider Electric’s Interactive Graphical SCADA System IGSS application. Schneider Electric has produced a patch that fully resolves this vulnerability. Aaron Portnoy has...
Schneider Electric Authenticated Communication Risk Vulnerability
OVERVIEW ICS-CERT received a report from Schneider Electric concerning an Authenticated Communication Risk vulnerability in the Schneider Electric Software Update SESU utility. This vulnerability was reported to Schneider Electric by security researcher Arthur Gervais. The SESU is a centralized...
Siemens SIMATIC RF Manager ActiveX Buffer Overflow
Overview This advisory provides mitigation details for a vulnerability that impacts the Siemens SIMATIC RF Manager. Siemens has identified a buffer overflow vulnerability in the ActiveX component of the SIMATIC RF Manager. Siemens has produced a patch that mitigates this vulnerability. Successful...
Rockwell Automation ControlLogix PLC Vulnerabilities
Overview This advisory is a follow up to the original alert titled ICS-ALERT-12-020-02A—Rockwell Automation ControlLogix PLC Vulnerabilities that was published February 14, 2012, on the ICS-CERT Web page. Independent researcher Rubén Santamarta of IOActive identified vulnerabilities in Rockwell...
SpecView Directory Traversal
Overview This advisory is a follow up to the original alert titled ICS-ALERT-12-214-01 SpecView Directory Traversal that was published August 01, 2012, on the ICS-CERT Web. This advisory provides mitigation details for a vulnerability, which impacts SpecView products. Independent researcher Luigi...
NovaTech Orion DNP3 Improper Input Validation Vulnerability
OVERVIEW Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation vulnerability in the NovaTech Orion Substation Automation Platform. NovaTech has produced a firmware update that mitigates this vulnerability. The researchers have tested the...
Schneider Electric CitectSCADA Products Exception Handler Vulnerability (Update A)
OVERVIEW --------- Begin Update A Part 1 of 1 -------- This updated advisory is a follow-up to the original advisory titled ICSA-13-350-01 Schneider Electric SCADA Products Exception Handler Vulnerability that was published February 25, 2014, on the NCCIC/ICS-CERT web site. This advisory was...
Siemens COMOS Privilege Escalation
OVERVIEW Siemens notified NCCIC/ICS-CERT of a privilege escalation vulnerability in the Siemens COMOS database application. An update has been produced by Siemens and is available to resolve the vulnerability. The client application used for accessing the database system might allow authenticated...
Cooper Power Systems Cybectec DNP3 Master OPC Server Improper Input Validation
OVERVIEW Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation vulnerability in Cooper Power Systems Cybectec DNP3 Master OPC Server software. Cooper Power Systems has discontinued the OPC server and recommends that customers use the SMP...
Cooper Power Systems Improper Input Validation Vulnerability
OVERVIEW Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation vulnerability in the Cooper Power Systems SMP Gateway DNP3 protocol components. Cooper Power Systems has produced a new firmware version that mitigates this vulnerability. Coope...
WellinTech Vulnerabilities
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on December 10, 2013, and is now being released to the NCCIC/ICS-CERT Web site. NCCIC/ICS-CERT received reports from the Zero Day Initiative ZDI regarding a remote code execution vulnerability and an information...
RuggedCom ROS Multiple Vulnerabilities
OVERVIEW Siemens has reported to NCCIC/ICS-CERT multiple vulnerabilities in the RuggedCom Rugged OS ROS. Siemens has produced a firmware update that mitigates these vulnerabilities. Exploitation of these vulnerabilities could allow an attacker to hijack an active Web session and access...
Siemens SINAMICS S/G Authentication Bypass Vulnerability
OVERVIEW Siemens has identified an authentication bypass vulnerability in the SINAMICS S/G product family. Siemens has produced a firmware update that mitigates this vulnerability and has tested the update to validate that it resolves the vulnerability. Exploitation of this vulnerability could...
Elecsys Director Gateway Improper Input Validation Vulnerability
OVERVIEW Adam Crain of Automatak and independent researchers Chris Sistrunk and Adam Todorski have identified an improper input validation in the Elecsys Director Gateway application. Elecsys has produced a patch that mitigates this vulnerability. Adam Todorski has tested the patch to validate th...
ClearSCADA Remote Authentication Bypass
Overview ICS-CERT originally released Advisory ICSA-11-173-01P “ClearSCADA Remote Authentication Bypass”, on the US-CERT Portal on June 22, 2011. This web page release was delayed to allow users sufficient time to download and install this update. Independent security researcher Jeremy Brown has...
Rockwell RSLinx EDS Vulnerability
Overview ICS-CERT has received a report from Michael Orlando of CERT Coordination Center CERT/CC identifying a vulnerability in Rockwell Automation Electronic Data Sheet EDS Hardware Installation Tool. This tool is bundled with RSLinx Classic for normal distribution. The install tool exhibits a...
ICONICS GENESIS32 Multiple Memory Corruption
Overview Independent security researchers Billy Rios and Terry McCorkle have identified eight memory corruption vulnerabilities affecting the ICONICS GENESIS32 product. GENESIS32 is a web-deployable human-machine interface HMI supervisory control and data acquisition SCADA product. These...
Ecava IntegraXor DLL Hijacking (Update B)
Overview This advisory is a follow-up to ICS-ALERT-10-362-01—Ecava IntegraXor DLL Hijacking. ICS-CERT has become aware of a Uncontrolled Search Path Element vulnerability, commonly referred to as DLL Hijacking, in the Ecava IntegraXor supervisory control and data acquisition SCADA product. ICS-CE...
Triangle Research Nano-10 PLC Improper Input Validation
OVERVIEW Researcher Wei Gao of IXIA has identified an improper input validation vulnerability in Triangle Research International, Inc.’s TRi Inc. Nano‑10 programmable logic controller PLC.IXIA Web site...
Siemens WinCC Exploitable Crashes
Overview ICS-CERT Advisory ICSA-11-175-02P was originally released to the US-CERT Portal on June 24, 2011. This web page release was delayed to allow users sufficient time to download and install the update. ICS-CERT has received a report from independent security researchers Billy Rios and Terry...
Catapult Software DNP3 Driver Improper Input Validation
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 24, 2013, and is now being released to the NCCIC/ICS-CERT Web site. Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation in Catapult Software’s DN...
GE Proficy DNP3 Improper Input Validation
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 24, 2013, and is now being released to the NCCIC/ICS-CERT Web site. General Electric GE Intelligent Platforms reported to NCCIC/ICS-CERT an improper input validation vulnerability in the DNP3 driver used...
WellinTech KingView ActiveX Vulnerabilities
OVERVIEW This advisory is a follow-up to the alert titled ICS-ALERT-13-256-01 WellinTech KingView ActiveX VulnerabilitiesICS-ALERT-13-256-01 WellinTech KingView ActiveX Vulnerabilities, http://ics-cert.us-cert.gov/alerts/ICS-ALERT-13-256-01, Web site last accessed October 22, 2013. that was...
Alstom e-Terracontrol DNP3 Master Improper Input Validation (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-13-282-01, Alstom e‑terra control DNP3 Master Improper Input Validation, which was posted to the NCCIC/ICS‑CERT Web site October 09, 2013. Adam Crain of Automatak and independent researcher Chris Sistrunk have...
Philips Xper Buffer Overflow Vulnerability
OVERVIEW Independent researcher Billy Rios has identified a heap-based buffer overflow in the Philips Xper application. Philips has produced an update that mitigates this vulnerability. Philips has tested the update and verified that it resolves the vulnerability. This vulnerability could be...
Invensys Wonderware InTouch Improper Input Validation Vulnerability
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 03, 2013, and is now being released to the NCCIC/ICS-CERT-Web page. This advisory provides mitigation details for a vulnerability that impacts the Invensys Wonderware InTouch application. Independent...
Siemens SCALANCE X-200 Authentication Bypass Vulnerability
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 01, 2013, and is now being released to the ICS-CERT-Web page. Siemens has identified an authentication bypass vulnerability in the SCALANCE X-200 switch product family. Researcher Eireann Leverett of...
Emerson ROC800 Multiple Vulnerabilities (Update B)
OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-13-259-01A Emerson ROC800 Multiple Vulnerabilities that was published December 2, 2014, on the NCCIC/ICS‑CERT web site. This advisory provides mitigation details for multiple vulnerabilities affecting the Emerson...
Emerson ROC800 Multiple Vulnerabilities (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-13-259-01 Emerson ROC800 Multiple Vulnerabilities that was published September 26, 2013, on the NCCIC/ICS‑CERT web site. This advisory provides mitigation details for multiple vulnerabilities affecting the Emerson...
Siemens SCALANCE X-200 Web Hijack Vulnerability
OVERVIEW Siemens has identified a Web hijack vulnerability in the SCALANCE X-200 switch product family. Researcher Eireann Leverett of IOActive coordinated disclosure of the vulnerability with Siemens. Siemens has produced a firmware update that mitigates this vulnerability. This vulnerability...
SUBNET Solutions Inc. SubSTATION Server DNP3 Outstation Improper Input Validation
OVERVIEW Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation in the SUBNET Solutions Inc. SubSTATION Server software application. SUBNET Solutions Inc. has produced a new version that mitigates this vulnerability. SUBNET Solutions Inc. ha...
ProSoft Technology RadioLinx ControlScape PRNG Vulnerability
OVERVIEW Lucas Apa and Carlos Mario Penagos Hollman, security researchers with IOActive, have identified a weak pseudo-random number generator PRNG seed in the ProSoft Technology RadioLinx ControlScape application software. ProSoft Technology has produced a new firmware patch that mitigates this...