added 2025/03/25 6:0 a.m.4 views

Rockwell Automation Verve Asset Manager

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker with administrative access to run arbitrary commands in the context of the container running the service. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of...

7.5CVSS7.4AI score0.00655EPSS
Exploits0References10
ICS
ICS
added 2025/02/11 12:0 a.m.4 views

Siemens SIPROTEC 5

SUMMARY Affected SIPROTEC 5 devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the sensitive information from the filesystem of the device. Siemens is preparing fix versions and recommends specific...

5.1CVSS6.7AI score0.00153EPSS
Exploits0References10
ICS
ICS
added 2025/02/11 12:0 a.m.4 views

Siemens Apogee PXC100 Devices

SUMMARY Apogee PXC and Talon TC contain a vulnerability that could allow an attacker to perform a denial of service using a out-of-bounds read forcing the device to enter a cold state and a vulnerability that would allow an attacker to decrypt the passwords of the device. Siemens recommends...

7.4AI score
Exploits0References10
ICS
ICS
added 2025/02/11 12:0 a.m.4 views

Siemens SIPROTEC 5 Devices

SUMMARY An information disclosure vulnerability in SIPROTEC 5 devices could allow an unauthenticated, remote attacker to retrieve sensitive information of the device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is...

8.7CVSS7AI score0.00539EPSS
Exploits0References10
ICS
ICS
added 2025/02/04 7:0 a.m.4 views

AutomationDirect C-more EA9 HMI

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition or achieve remote code execution on the affected device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of...

9.8CVSS7.7AI score0.00815EPSS
Exploits0References10
ICS
ICS
added 2025/01/30 7:0 a.m.4 views

New Rock Technologies Cloud Connected Devices

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker full control of the device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all...

9.8CVSS7.3AI score0.00598EPSS
Exploits1References10
ICS
ICS
added 2025/01/16 12:0 a.m.4 views

TrueFiling authorization bypass via user-controlled keys

RISK EVALUATION TrueFiling trusts some client-controlled identifiers passed in URL requests to retrieve information. Platform users must self-register for an account, and once authenticated, could manipulate those identifiers to gain partial access to case information and the ability to...

6.3CVSS6.6AI score0.00317EPSS
Exploits0References1
ICS
ICS
added 2024/12/10 5:0 a.m.4 views

Schneider Electric Modicon

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

9.8CVSS6.5AI score0.00629EPSS
Exploits0References11
ICS
ICS
added 2024/12/10 12:0 a.m.4 views

Siemens Simcenter Femap

SUMMARY Simcenter Femap contains multiple memory corruption vulnerabilities that could be triggered when the application reads files in BDF file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead...

8.2AI score
Exploits0References10
ICS
ICS
added 2024/11/12 12:0 a.m.4 views

Siemens Engineering Platforms

SUMMARY Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to...

7.3CVSS7.8AI score0.00219EPSS
Exploits0References10
ICS
ICS
added 2024/10/08 12:0 a.m.4 views

Schneider Electric Data Center Expert

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

7.3AI score
Exploits0References11
ICS
ICS
added 2023/06/27 12:0 a.m.4 views

Hitachi Energy Relion 670, 650, SAM600-IO Series (Update A)

SUMMARY Hitachi Energy is aware of the vulnerability CVE-2022-4304 in the OSS component OpenSSL, that affects the Relion 670, 650, SAM600-IO versions that are listed below. An attacker successfully exploiting this vulnerability could send trial messages to the server and record the time taken to...

5.9CVSS7.1AI score0.16195EPSS
Exploits0References9
ICS
ICS
added 2022/11/29 11:49 a.m.4 views

Festo Firmware

SUMMARY Incomplete Festo product documentation of remote accessible functions and their required IP ports. Depending on the product a description of the supported features can be found in the product documentation to some extent. Update A, 2022-12-13 Added affected device "Bus module CPX-E-PN,...

9.8CVSS6.7AI score0.01053EPSS
Exploits0References12
ICS
ICS
added 2022/09/20 10:0 a.m.4 views

Festo CPX-CEC-C1 and CPX-CMXX

SUMMARY Unauthenticated access to critical webpage functions e.g. reboot may cause a denial of service of the device. 2. IMPACT CPX-CEC-C1 and CPX-CMXX allow unauthenticated access to critical webpage functions e.g. reboot which may cause a denial of service of the device 3. REMEDIATION...

7.5CVSS6.9AI score0.00662EPSS
Exploits0References13
ICS
ICS
added 2021/09/22 11:13 a.m.4 views

Festo SBRD-Q/SBOC-Q/SBOI-Q

SUMMARY The affected product families are cameras SBOC/SBOI and the Controller SBRD. The vulnerabilities are located within the Ethernet IP Stack from EIPStackGroup OpENer Ethernet/IP. 2. IMPACT Please consult the CVEs listed above and ICSA-21-105-02. 3. MITIGATION - Minimize network exposure...

6.7AI score
Exploits0References12
ICS
ICS
added 4 days ago3 views

Delta Electronics DTM Soft

ADVISORY SUMMARY Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system...

6.2AI score
Exploits0References13
ICS
ICS
added 2026/06/09 12:0 a.m.3 views

Siemens SIPROTEC 5 Using DIGSI5 Protocol

SUMMARY SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150...

6.9CVSS6.2AI score0.00186EPSS
Exploits0References10
ICS
ICS
added 2026/06/09 12:0 a.m.3 views

Siemens Products using OpenSSL

SUMMARY OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service DoS or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest...

8.8CVSS6.6AI score0.45854EPSS
Exploits7References10
ICS
ICS
added 2026/03/10 7:0 a.m.3 views

Schneider Electric EcoStruxure Foxboro DCS

GENERAL SECURITY RECOMMENDATIONS Schneider Electric strongly recommends the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business...

7CVSS6.6AI score0.00315EPSS
Exploits0References11
ICS
ICS
added 2026/03/10 12:0 a.m.3 views

Siemens SICAM SIAPP SDK

SUMMARY The SICAM SIAPP SDK contains multiple vulnerabilities that could allow an attacker to disrupt the customer-developed SIAPP or its simulation environment. Potential impacts include denial of service within the SIAPP, corruption of SIAPP data, or exploit the simulation environment. These...

6.5AI score
Exploits0References10
ICS
ICS
added 2026/02/26 7:0 a.m.3 views

Pelco, Inc. Sarix Pro 3 Series IP Cameras

RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to gain unauthorized access to sensitive device data, bypass surveillance controls, and expose facilities to privacy breaches, operational risks, and regulatory compliance issues. 2. RECOMMENDED PRACTICES CISA...

8.7CVSS5.5AI score0.00348EPSS
Exploits0References11
ICS
ICS
added 2026/02/23 12:0 a.m.3 views

Census CSWeb multiple vulnerabilities

RISK EVALUATION Census CSWeb allows a remote, authenticated attacker to perform actions such as path traversal, arbitrary file upload and stored XSS. An unauthenticated attacker could also send requests to configuration files in some deployments. 2. RECOMMENDED PRACTICES Update to 8.1.0 alpha...

8.8CVSS6AI score0.00526EPSS
Exploits0References1
ICS
ICS
added 2026/02/10 12:0 a.m.3 views

Siemens Solid Edge

SUMMARY Solid Edge uses PS/IGES Parasolid Translator Component that contains an out of bounds read that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to...

7.8CVSS6.1AI score0.00178EPSS
Exploits0References10
ICS
ICS
added 2026/01/16 12:30 a.m.3 views

ABB Ability OPTIMAX

SUMMARY ABB became aware of severe vulnerability in the products versions listed as affected in the advisory, if the optional integration with Azure Active Directory for Single-Sign On is enabled. We have not received any reports of this vulnerability being exploited. An attacker who...

9.2CVSS6.3AI score0.0039EPSS
Exploits0References12
ICS
ICS
added 2026/01/13 8:0 a.m.3 views

Schneider Electric Zigbee Products

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

6AI score
Exploits0References11
ICS
ICS
added 2026/01/13 12:0 a.m.3 views

Siemens Industrial Edge Device Kit

SUMMARY Users of Industrial Edge Devices are advised to consult the respective Security Advisories for their devices for Siemens Industrial Edge devices see Additional Information. Industrial Edge Device Kit contains an authorization bypass vulnerability that could facilitate an unauthenticated...

10CVSS7.1AI score0.00601EPSS
Exploits0References10
ICS
ICS
added 2026/01/07 4:35 p.m.3 views

OPEXUS eComplaint and eCasePortal IDOR

RISK EVALUATION OPEXUS eCasePortal and eComplaint before version 9.0.45.0 allow an unauthenticated attacker to iterate through predictable URL parameters and download all available files. The eCasePortal vulnerability allows attackers to upload and delete files as well. 2. RECOMMENDED PRACTICES...

9.8CVSS6.8AI score0.00375EPSS
Exploits0References1
ICS
ICS
added 2025/12/10 4:46 p.m.3 views

Windscribe for Linux 'changeMTU' local privilege escalation

RISK EVALUATION A command injection vulnerability exists in Windscribe for Linux Desktop App that allows a local user who is a member of the windscribe group to execute arbitrary commands as root via the 'adapterName' parameter of the 'changeMTU' function. Fixed in Windscribe v2.18.3-alpha and...

7.8CVSS7.8AI score0.01094EPSS
Exploits1References1
ICS
ICS
added 2025/11/25 7:0 a.m.3 views

Festo Compact Vision System, Control Block, Controller, and Operator Unit products

RISK EVALUATION Successful exploitation of these vulnerabilities could result in an attacker accessing devices without authentication or modifying configuration files. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these...

7AI score
Exploits0References13
ICS
ICS
added 2025/11/18 7:0 a.m.3 views

Shelly Pro 3EM

RISK EVALUATION Successful exploitation of this vulnerability could result in a denial-of-service condition. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control...

8.3CVSS6.8AI score0.00172EPSS
Exploits0References11
ICS
ICS
added 2025/11/13 7:0 a.m.3 views

AVEVA Application Server IDE

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to tamper with help files and inject cross-site scripting XSS code. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:...

7.2CVSS6.4AI score0.00135EPSS
Exploits0References13
ICS
ICS
added 2025/10/22 6:45 p.m.3 views

IBM DOORS Next Generation multiple vulnerabilities

RISK EVALUATION IBM Engineering Requirements Management DOORS contains multiple vulnerabilities that require authentication. These vulnerabilities include the ability to cause an application denial of service and JavaScript execution in the victim's browser through stored cross site scripting...

6.5AI score
Exploits0References1
ICS
ICS
added 2025/10/21 6:0 a.m.3 views

Oxford Nanopore Technologies MinKNOW

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disrupt sequencing operations and processes, exfiltrate and manipulate data, and bypass authentication controls. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk...

7.3AI score
Exploits0References13
ICS
ICS
added 2025/10/14 12:0 a.m.3 views

Siemens SiPass Integrated

SUMMARY SiPass integrated before V3.0 contains multiple vulnerabilities that could allow an unauthenticated remote attacker to exploit user accounts, manipulate data, impersonate users, or achieve arbitrary code execution on the SiPass integrated server. Siemens has released a new version for...

9.3AI score
Exploits0References10
ICS
ICS
added 2025/09/23 6:0 a.m.3 views

AutomationDirect CLICK PLUS

RISK EVALUATION Successful exploitation of these vulnerabilities disclose sensitive information, modify device settings, escalate privileges, or cause a denial-of-service condition on the affected device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk...

6.7AI score
Exploits0References13
ICS
ICS
added 2025/09/18 6:0 a.m.3 views

Cognex In-Sight Explorer and In-Sight Camera Firmware

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, steal credentials, modify files, or cause a denial-of-service condition. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of...

6.9AI score
Exploits0References10
ICS
ICS
added 2025/09/16 6:0 a.m.3 views

Hitachi Energy RTU500 series

RISK EVALUATION Successful exploitation of these vulnerabilities could cause a Denial-of-Service condition in RTU500 devices. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure...

7.3AI score
Exploits0References10
ICS
ICS
added 2025/09/09 8:48 p.m.3 views

OPEXUS FOIAXpress Public Access Link (PAL) SQL injection

RISK EVALUATION Successful exploitation could allow a remote, unauthenticated attacker to read, write, or delete any content in the underlying database. 2. RECOMMENDED PRACTICES Upgrade to FOIAXpress PAL version 11.13.1.0. 3. DESCRIPTION OPEXUS FOIAXpress Public Access Link PAL before version...

9.8CVSS7.6AI score0.00616EPSS
Exploits0References1
ICS
ICS
added 2025/09/09 5:0 a.m.3 views

ABB Cylon Aspect BMS/BAS

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to assume control of the target device or perform a denial-of-service DoS attack. 2. RECOMMENDED PRACTICES CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying...

6.9AI score
Exploits0References10
ICS
ICS
added 2025/09/02 6:0 a.m.3 views

Fuji Electric FRENIC-Loader 4

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control...

8.4CVSS7.3AI score0.00186EPSS
Exploits0References10
ICS
ICS
added 2025/09/02 6:0 a.m.3 views

SunPower PVS6

RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to gain full access to the device, enabling them to replace firmware, modify settings, disable the device, create SSH tunnels, and manipulate attached devices. 2. RECOMMENDED PRACTICES CISA recommends users take...

9.4CVSS7AI score0.00164EPSS
Exploits0References10
ICS
ICS
added 2025/08/28 6:0 a.m.3 views

Delta Electronics COMMGR

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code. 2. RECOMMENDED PRACTICES CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for...

8.6CVSS7.9AI score0.00376EPSS
Exploits0References10
ICS
ICS
added 2025/08/28 6:0 a.m.3 views

Mitsubishi Electric MELSEC iQ-F Series CPU Module

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker the ability to obtain credential information by intercepting SLMP communication messages, and read or write the device values of the product by using the obtained credential information. In addition, the...

7.5CVSS6.2AI score0.00311EPSS
Exploits0References10
ICS
ICS
added 2025/08/12 4:0 a.m.3 views

Schneider Electric SESU

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

7.3CVSS6.9AI score0.00198EPSS
Exploits0References11
ICS
ICS
added 2025/08/12 4:0 a.m.3 views

Schneider Electric Saitel DR & Saitel DP Remote Terminal Unit

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

8.4CVSS7.9AI score0.00179EPSS
Exploits0References11
ICS
ICS
added 2025/08/12 12:0 a.m.3 views

Siemens SINUMERIK

SUMMARY Siemens SINUMERIK Controllers are affected by an improper VNC password check vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends...

8.7CVSS7.8AI score0.00228EPSS
Exploits0References10
ICS
ICS
added 2025/08/12 12:0 a.m.3 views

Siemens BFCClient

SUMMARY Siemens BFCClient contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, to change the application behaviour or to create a denial of service condition. Siemens has released a new version for BFCClient and recommends to...

8.9AI score
Exploits0References10
ICS
ICS
added 2025/08/07 6:0 a.m.3 views

Burk Technology ARC Solo

RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker gaining access to the device, locking out authorized users, or disrupting operations. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this...

9.8CVSS7.6AI score0.00873EPSS
Exploits0References10
ICS
ICS
added 2025/08/07 6:0 a.m.3 views

Johnson Controls FX Server, FX80 and FX90 (Update A)

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to compromise the device's configuration files. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network...

6.6AI score
Exploits0References11
ICS
ICS
added 2025/08/07 12:0 a.m.3 views

Tyler Technologies ERP Pro 9

RISK EVALUATION Tyler Technologies ERP Pro 9 SaaS allows an authenticated user to escape the application and execute limited operating system commands. 2. RECOMMENDED PRACTICES Tyler Technologies deployed hardened environment settings to all ERP Pro 9 SaaS customer environments as of 2025-08-01...

7.4CVSS6.6AI score0.00197EPSS
Exploits0References1