1624 matches found
Circontrol CirCarLife
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Circontrol Equipment: CirCarLife Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of these...
GEOVAP Reliance 4 SCADA/HMI
1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GEOVAP Equipment: Reliance 4 SCADA/HMI Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to use HTTP proxy...
TRITON Attribution: Russian Government-Owned Lab Most Likely Built Custom Intrusion Tools for TRITON Attackers
Overview In a previous blog post we detailed the TRITON intrusion that impacted industrial control systems ICS at a critical infrastructure facility. We now track this activity set as TEMP.Veles. In this blog post we provide additional information linking TEMP.Veles and their activity surrounding...
icsd.ill.fr XSS vulnerability
Open Bug Bounty ID: OBB-688803 Description| Value ---|--- Affected Website:| icsd.ill.fr Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| hidden until disclosure Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:| hidden unti...
Remote Code Implantation Flaw Found in Medtronic Cardiac Programmers
A flaw in Medtronic’s CareLink 2090 and CareLink Encore 29901 programmers, which are portable computer systems used to manage implanted cardiac devices in clinical settings, would have allowed remote code implantation over Medtronic’s dedicated Software Deployment Network SDN. The programmers are...
NotPetya Linked to Industroyer Attack on Ukraine Energy Grid
The massive NotPetya ransomware outbreak that crippled organizations around the world last year turns out to have links to the Industroyer backdoor, which targets industrial control systems ICS and took down the Ukrainian power grid in Kiev in 2016. In fact, the same threat actor – dubbed TeleBot...
ICS Security Plagued with Basic, Avoidable Mistakes
At least 33 percent of the security issues found in industrial control systems ICS are rated as being of high or critical risk. FireEye iSIGHT Intelligence compiled data from dozens of ICS security health assessment engagements performed by its Mandiant division, and found that these issues inclu...
ICS Tactical Security Trends: Analysis of the Most Frequent Security Risks Observed in the Field
Introduction FireEye iSIGHT Intelligence compiled extensive data from dozens of ICS security health assessment engagements ICS Healthcheck performed by Mandiant, FireEye's consulting team, to identify the most pervasive and highest priority security risks in industrial facilities. The information...
NUUO NVRmini2 and NVRsolo
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit/public exploits are available Vendor: NUUO Equipment: NVRmini2, NVRsolo Vulnerabilities: Stack-based Buffer Overflow, Leftover Debug Code 2. RISK EVALUATION Successful exploitation of these...
GE iFix
1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE Equipment: Gigasoft component of iFix Vulnerability: Unsafe ActiveX Control Marked Safe For Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a buffer...
GE Communicator
1. EXECUTIVE SUMMARY CVSS v3 7.6 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE Equipment: Communicator Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Exploitation could allow attackers to execute arbitrary code or create a denial-of-service condition. 3...
Threats posed by using RATs in ICS
While conducting audits, penetration tests and incident investigations, we have often come across legitimate remote administration tools RAT for PCs installed on operational technology OT networks of industrial enterprises. In a number of incidents that we have investigated, threat actors had use...
Delta Electronics Delta Industrial Automation COMMGR 1.08 Stack Buffer Overflow
This module exploits a stack based buffer overflow in Delta Electronics Delta Industrial Automation COMMGR 1.08. The vulnerability exists in COMMGR.exe when handling specially crafted packets. This module has been tested successfully on Delta Electronics Delta Industrial Automation COMMGR 1.08 ov...
Denial Of Service (DoS)
libical.so is vulnerable to a denial of service attack. A malicious user can pass an ics file that when parsed, causes a use-after-free that can crash the application...
Mail.ru: ДОБАВЛЕНИЕ СВОИХ ДАТ В КАЛЕНДАРЬ ПОЛЬЗОВАТЕЛЮ !
Reporter pointed to possibility to mark scheduled meeting request sent via ICS file as accepted in calendar via CSRF by bruteforcing attachment id. Currently, this behavior is not believed to introduce real additional security risks, because meeting can be added anyway without user's intervention...
Fuji Electric V-Server Lite
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Fuji Electric Equipment: V-Server Lite Vulnerability: Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to view sensitive...
Schneider Electric StruxureWare Building Expert Plaintext Credentials Vulnerability
OVERVIEW Independent researcher Artyom Kurbatov has identified a cleartext transmission vulnerability in Schneider Electric’s StruxureWare Building Expert product. Schneider Electric has produced a new firmware version that mitigates this vulnerability. Artyom Kurbatov has tested the new firmware...
Siemens Tecnomatix FactoryLink Vulnerabilities (Update A)
Overview This ICS-CERT Advisory is a follow-up to ICS-ALERT-11-080-01. An independent researcher has identified six vulnerabilities in the Siemens Tecnomatix FactoryLink supervisory control and data acquisition SCADA product. The researcher has also publicly released exploit code. The researcher...
SCADA Engine BACnet OPC Client Buffer Overflow Vulnerability
Overview This advisory is a follow-up to ICS-ALERT-10-260-01 SCADA Engine BACnet OPC Client Buffer Overflow, which was published on the ICS-CERT Web site on September 17, 2010. A buffer overflow vulnerability has been reportedSecunia Advisory SA41466, http://secunia.com/advisories/41466/, website...
DNP3 Implementation Vulnerability (Update B)
OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-13-291-01A DNP3 Implementation Vulnerability that was published November 21, 2013, on the NCCIC/ICS-CERT web site. Adam Crain of Automatak and Chris Sistrunk, Sr. Consultant for Mandiant, reported an improper input...