1715 matches found
WECON PLC Editor
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: WECON Equipment: PLC Editor Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation could allow an attacker to execute code under the privileges of the application. 3. TECHNICAL DETAILS...
Moxa EDS Ethernet Switches
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Moxa Equipment: EDS-G508E, EDS-G512E, and EDS-G516E Series Ethernet Switches Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could...
EulerOS 2.0 SP3 : libical (EulerOS-SA-2019-2607)
According to the versions of the libical packages installed, the EulerOS installation on the remote host is affected by the following vulnerabilities : - libical allows remote attackers to cause a denial of service use-after-free and possibly read heap memory via a crafted ics file.CVE-2016-9584 ...
Talos Vulnerability Discovery Year in Review — 2019
By Martin Zeiser. Cisco Talos' Systems Security Research Team investigates software, operating system, IoT and ICS vulnerabilities to make sure we find vulnerabilities before the bad guys do. We provide this information to the affected vendors so that they can create patches and protect their...
Siemens RUGGEDCOM ROS (Update A)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Fuji Electric V-Server
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Fuji Electric Equipment: V-Server Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the device being accessed; several heap-based buffer overflows...
Pwn2Own Expands Into Industrial Control Systems Hacking
Industrial control systems ICS used to manage critical infrastructure and manufacturing will be the main target in next year’s popular Pwn2Own’s annual hacking competition. Over the past few years, Pwn2Own – a hacking contest that draws in white-hat hackers looking for fame and fortune through...
Moxa EDR-810 - Command Injection / Information Disclosure
During an engagement for a client, RandoriSec found 2 vulnerabilities on Moxa EDR-810 Series Secure Routers. The first one is a command injection vulnerability found on the CLI allowing an authenticated user to obtain root privileges. And the other one is an improper access control found on the w...
Moxa EDR-810 - Command Injection / Information Disclosure Vulnerabilities
During an engagement for a client, RandoriSec found 2 vulnerabilities on Moxa EDR-810 Series Secure Routers. The first one is a command injection vulnerability found on the CLI allowing an authenticated user to obtain root privileges. And the other one is an improper access control found on the w...
Moxa EDR-810 - Command Injection Information Disclosure
Moxa EDR-810 - Command Injection Information Disclosure During an engagement for a client, RandoriSec found 2 vulnerabilities on Moxa EDR-810 Series Secure Routers. The first one is a command injection vulnerability found on the CLI allowing an authenticated user to obtain root privileges. And th...
On-Board 'Mystery Boxes' Threaten Global Shipping Vessels
Commercial shipping environments are rife with vulnerabilities, according to researchers – up to and including unpatched “mystery boxes” that no one knows anything about. “In every single nautical pen test to date we have unearthed a system or device, that of the few crew that were aware, no one...
Operational Technology Networks or OT
Operational Technology Networks or OT Notes: It’s mixing up OT with maritime, so probably isn’t suitable as is. The first section is really good, very relevant. We can use all of that. Once we get in to NMEA data, then it goes off topic. I suggest: Network equipment such as the Scalance Then a...
SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery
Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Date: 2019-10-08 Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware Version 1.6 and prior Tested on: Sunny WebBox SMA Solar Device Firmware Version...
SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery
SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Date: 2019-10-08 Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware...
SMA Solar Technology AG Sunny WebBox 1.6 Cross Site Request Forgery
Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Date: 2019-10-08 Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware Version 1.6 and prior Tested on: Sunny WebBox SMA Solar Device Firmware Version...
SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Vulnerability
Exploit for hardware platform in category web applications Exploit Title: SMA Solar Technology AG Sunny WebBox device - 1.6 - Cross-Site Request Forgery Exploit Author: Borja Merino and Eduardo Villaverde Vendor Homepage: https://www.sma.de Version: Firmware Version 1.6 and prior Tested on: Sunny...
GE Mark VIe Controller
1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Low skill level to exploit Vendor: GE Equipment: Mark VIe Controller Vulnerabilities: Improper Authorization, Use of Hard-coded Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to create...
Siemens PROFINET Devices (Update K)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
EulerOS 2.0 SP5 : libical (EulerOS-SA-2019-1915)
According to the version of the libical packages installed, the EulerOS installation on the remote host is affected by the following vulnerability : - libical allows remote attackers to cause a denial of service use-after-free and possibly read heap memory via a crafted ics file.CVE-2016-9584 Not...
Pwning a Siemens Scalance ICS switch through ARM reversing
We’ve been working in industrial control systems security for a long time. Several of the team here used to work in OT control rooms or support SCADA environments. Whilst pen testing a ship control system, we noticed a heavy reliance on Siemens Scalance industrial ethernet switches, so bought a...