Lucene search

K
icsIndustrial Control Systems Cyber Emergency Response TeamICSA-20-056-02
HistoryFeb 25, 2020 - 12:00 p.m.

Moxa ioLogik 2542-HSPA Series Controllers and IOs, and IOxpress Configuration Utility

2020-02-2512:00:00
Industrial Control Systems Cyber Emergency Response Team
www.cisa.gov
41

CVSS2

5

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

AI Score

8.1

Confidence

High

EPSS

0.002

Percentile

52.9%

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5 ***ATTENTION: **Exploitable remotely/low skill level to exploit
  • Vendor: Moxa
  • **Equipment:**ioLogik 2542-HSPA Series Controllers and IOs, and IOxpress Configuration Utility
  • Vulnerabilities: Cleartext Storage of Sensitive Information, Cleartext Transmission of Sensitive Information, Incorrectly Specified Destination in a Communication Channel

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could crash the device or allow access to sensitive information.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Moxa reports these vulnerabilities affects the following products:

  • ioLogik 2500 series firmware, Version 3.0 or lower
  • IOxpress configuration utility, Version 2.3.0 or lower

3.2 VULNERABILITY OVERVIEW

3.2.1 CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312

Sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account.

CVE-2019-18238 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.2 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319

Sensitive information is transmitted over some web applications in clear text.

CVE-2020-7003 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.3 INCORRECTLY SPECIFIED DESTINATION IN A COMMUNICATION CHANNEL CWE-941

Frequent and multiple requests for short-term use may cause the web server to fail.

CVE-2019-18242 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Energy, Water and Wastewater Systems
  • **COUNTRIES/AREAS DEPLOYED:**Worldwide
  • **COMPANY HEADQUARTERS LOCATION:**Taiwan

3.4 RESEARCHER

Ilya Karpov and Evgeniy Druzhinin from Rostelecom-Solar reported these vulnerabilities to Moxa.

4. MITIGATIONS

Moxa has developed a solution to address these vulnerabilities: Please contact Moxa Technical Support for a security patch.

Please see Moxa’s security advisory for more information.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:

  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploits specifically target these vulnerabilities.

References

CVSS2

5

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

AI Score

8.1

Confidence

High

EPSS

0.002

Percentile

52.9%

Related for ICSA-20-056-02