Lucene search
+L

1047 matches found

Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•43 views

CVE-2011-4878

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexibl...

6.6AI score0.11092EPSS
SaveExploits1References8
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•45 views

CVE-2011-4879

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle UR...

6.6AI score0.12105EPSS
SaveExploits1References8
CVE
CVE
•added 2012/02/03 8:00 p.m.•93 views

CVE-2011-4508

CVE-2011-4508: Insecure, predictable authentication token generation in Siemens WinCC/HMI web servers (WinCC flexible 2004–2008 before SP3; WinCC V11 before SP2 Update 1; and related HMI panels) allows remote attackers to bypass authentication by crafting cookies. Affected components include HMI ...

9.3CVSS6.8AI score0.02979EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•105 views

CVE-2011-4509

CVE-2011-4509 affects Siemens WinCC/WinCC flexible products (2004–2008, WinCC V11, and related SIMATIC HMI panels). The root cause is an improperly selected default administrator password, which enables remote attackers to gain access by brute-forcing via many HTTP requests. Public citations in c...

10CVSS6.7AI score0.01975EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•74 views

CVE-2011-4510

CVE-2011-4510 and CVE-2011-4511 describe cross-site scripting (XSS) in the Siemens SIMATIC WinCC/HMI Web server. Affected products include WinCC flexible 2004–2008 (before SP3), WinCC V11 (TIA Portal) before SP2 Update 1, and multiple SIMATIC HMI panels, plus WinCC V11 Runtime Advanced and WinCC ...

4.3CVSS5.7AI score0.0142EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•80 views

CVE-2011-4511

CVE-2011-4511 is a cross-site scripting (XSS) vulnerability in the Siemens SIMATIC WinCC HMI web server. Affected products (per ICS-CERT) include WinCC flexible 2004/2005/2007/2008 (before SP3), WinCC V11 (TIA Portal) before SP2 Update 1, and multiple SIMATIC HMI panels plus WinCC V11 Runtime Adv...

4.3CVSS5.7AI score0.0142EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•74 views

CVE-2011-4512

CVE-2011-4512 is a CRLF/header-injection vulnerability in the Siemens SIMATIC WinCC/HMI web server. Affected products include WinCC flexible 2004/2005/2007/2008 before SP3; WinCC V11 (TIA Portal) before SP2 Update 1; multiple SIMATIC HMI panels (TP/OP/MP/Comfort/Mobile); WinCC V11 Runtime Advance...

5CVSS6.9AI score0.0161EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•74 views

CVE-2011-4513

CVE-2011-4513 affects Siemens WinCC Flexible (2004–2008), WinCC V11 (TIA Portal), SIMATIC HMI panels (TP/OP/MP/Comfort/Mobile), and WinCC Runtime Advanced/Flexible Runtime. The vulnerability allows user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the...

10CVSS7.8AI score0.04776EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•80 views

CVE-2011-4514

CVE-2011-4514 concerns the TELNET daemon in Siemens WinCC flexible (2004–2008) and WinCC V11 (TIA Portal), plus related SIMATIC HMI panels, which does not perform authentication, enabling remote access via TCP sessions. Affected products include WinCC flexible 2004/2005/2007/2008, WinCC V11, TP/O...

10CVSS6.6AI score0.03377EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•85 views

CVE-2011-4875

CVE-2011-4875 corresponds to a stack-based buffer overflow in the HmiLoad runtime loader of Siemens WinCC flexible (versions 2004, 2005, 2007, 2008) and WinCC V11 (TIA Portal) including SIMATIC HMI panels and WinCC V11 Runtime Advanced. The root cause is improper handling/validation of Unicode st...

9.3CVSS8.2AI score0.13841EPSS
SaveExploits1References8Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•80 views

CVE-2011-4876

CVE-2011-4876 is a directory traversal vulnerability in Siemens WinCC family runtimes (WinCC flexible 2004–2008, WinCC V11/TIA Portal, and related SIMATIC HMI panels) where the runtime loader HmiLoad fails to validate strings during Transfer Mode. This allows remote attackers to access or modify ...

9.3CVSS6.9AI score0.09046EPSS
SaveExploits1References9Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•74 views

CVE-2011-4877

CVE-2011-4877 affects Siemens WinCC flexible products (2004–2008) and related SIMATIC HMI panels, WinCC V11 Runtime Advanced, and WinCC flexible Runtime. The issue lies in HmiLoad in the runtime loader; when Transfer Mode is enabled, sending crafted data over TCP can cause a remote denial of serv...

7.1CVSS6.7AI score0.07259EPSS
SaveExploits1References8Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•73 views

CVE-2011-4878

Siemens WinCC/HMI Web Server is vulnerable to a directory traversal in the HMI web server component (miniweb.exe) affecting WinCC flexible 2004–2008, WinCC V11 (TIA Portal) before SP2 Update 1, and related SIMATIC HMI panels and runtimes. Root cause: improper validation of HTTP/URI strings allows...

7.8CVSS6.8AI score0.11092EPSS
SaveExploits1References8Affected Software1
CVE
CVE
•added 2012/02/03 8:00 p.m.•77 views

CVE-2011-4879

Siemens WinCC/HMI Web Server vulnerability CVE-2011-4879: the HMI web server (miniweb.exe) fails to properly handle URIs beginning with 0xfa, enabling remote memory reads or DoS via crafted POST requests. Affected products include WinCC flexible 2004–2008 (pre-SP3), WinCC V11 (TIA Portal) before ...

8.5CVSS6.9AI score0.12105EPSS
SaveExploits1References8Affected Software1
Positive Technologies
Positive Technologies
•added 2012/02/03 12:00 a.m.•4 views

PT-2012-1978

Name of the Vulnerable Software and Affected Versions Siemens WinCC flexible versions 2004 through 2008 WinCC V11 aka TIA portal TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels WinCC V11 Runtime Advanced WinCC flexible Runtime Description The issue is related to a stack-based...

9.3CVSS0.13841EPSS
SaveExploits1References10
Positive Technologies
Positive Technologies
•added 2012/02/03 12:00 a.m.•5 views

PT-2012-1979

Name of the Vulnerable Software and Affected Versions Siemens WinCC flexible versions 2004 through 2008 Siemens WinCC V11 aka TIA portal Siemens TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels Siemens WinCC V11 Runtime Advanced Siemens WinCC flexible Runtime Description The issue...

9.3CVSS0.09046EPSS
SaveExploits1References11
Positive Technologies
Positive Technologies
•added 2012/02/03 12:00 a.m.•3 views

PT-2012-1895

Name of the Vulnerable Software and Affected Versions Siemens WinCC flexible versions 2004 through 2008 before SP3 Siemens WinCC V11 aka TIA portal versions prior to SP2 Update 1 Siemens TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels affected versions not specified Siemens WinCC...

4.3CVSS0.0142EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2012/02/03 12:00 a.m.•5 views

PT-2012-1898

Name of the Vulnerable Software and Affected Versions Siemens WinCC flexible versions 2004 through 2008 Siemens WinCC V11 aka TIA portal Siemens TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels Siemens WinCC V11 Runtime Advanced Siemens WinCC flexible Runtime Description The issue...

10CVSS0.03377EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2012/02/03 12:00 a.m.•3 views

PT-2012-1897

Name of the Vulnerable Software and Affected Versions Siemens WinCC flexible versions 2004 through 2008 WinCC V11 aka TIA portal WinCC V11 Runtime Advanced WinCC flexible Runtime TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels affected versions not specified Description The issue...

10CVSS0.04776EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2012/02/03 12:00 a.m.•3 views

PT-2012-1982

Name of the Vulnerable Software and Affected Versions Siemens WinCC flexible versions 2004 through 2008 before SP3 Siemens WinCC V11 aka TIA portal versions prior to SP2 Update 1 Siemens TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels affected versions not specified Siemens WinCC...

8.5CVSS0.12105EPSS
SaveExploits1References10
Rows per page