Lucene search
+L

1047 matches found

Prion
Prion
•added 2012/02/03 8:55 p.m.•24 views

Default credentials

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account...

10CVSS7.1AI score0.01975EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•36 views

Cross site scripting

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

4.3CVSS5.9AI score0.0142EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•33 views

Crlf injection

CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows...

5CVSS7.3AI score0.0161EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•30 views

Authentication flaw

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attacker...

10CVSS7AI score0.03377EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•33 views

Cross site scripting

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

4.3CVSS5.9AI score0.0142EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•28 views

Code injection

Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file,...

10CVSS8.1AI score0.04776EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•29 views

Directory traversal

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexibl...

7.8CVSS7.1AI score0.11092EPSS
SaveExploits1References8Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•28 views

Directory traversal

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is...

9.3CVSS7.2AI score0.09046EPSS
SaveExploits1References9Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•24 views

Cross site request forgery (csrf)

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle UR...

8.5CVSS7.2AI score0.12105EPSS
SaveExploits1References8Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•29 views

Stack overflow

Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled,...

9.3CVSS8.7AI score0.13841EPSS
SaveExploits1References8Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•27 views

Code injection

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cau...

7.1CVSS7.1AI score0.07259EPSS
SaveExploits1References8Affected Software3
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•46 views

CVE-2011-4508

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication token...

6.6AI score0.02979EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•50 views

CVE-2011-4509

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account...

6.5AI score0.01975EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•50 views

CVE-2011-4510

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

5.5AI score0.0142EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•46 views

CVE-2011-4511

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

5.5AI score0.0142EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•58 views

CVE-2011-4513

Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file,...

7.5AI score0.04776EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•52 views

CVE-2011-4514

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attacker...

6.4AI score0.03377EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•43 views

CVE-2011-4875

Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled,...

7.9AI score0.13841EPSS
SaveExploits1References8
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•47 views

CVE-2011-4876

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is...

6.6AI score0.09046EPSS
SaveExploits1References9
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•49 views

CVE-2011-4877

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cau...

6.5AI score0.07259EPSS
SaveExploits1References8