Lucene search
+L

1047 matches found

Positive Technologies
Positive Technologies
•added 2012/06/08 12:00 a.m.•5 views

PT-2012-4123

Name of the Vulnerable Software and Affected Versions Siemens WinCC version 7.0 SP3 before Update 2 Description The issue concerns multiple cross-site scripting XSS vulnerabilities in unspecified web applications. These vulnerabilities allow remote attackers to inject arbitrary web script or HTML...

4.3CVSS0.01513EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2012/06/08 12:00 a.m.•4 views

PT-2012-4124

Name of the Vulnerable Software and Affected Versions Siemens WinCC version 7.0 SP3 before Update 2 Description The issue concerns the XPath functionality in web applications, which does not properly handle special characters in parameters. This allows remote authenticated users to read or modify...

5.5CVSS0.01504EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2012/06/08 12:00 a.m.•7 views

PT-2012-4126

Name of the Vulnerable Software and Affected Versions Siemens WinCC versions 7.0 SP3 through Update 2 Description The issue is related to a buffer overflow in the DiagAgent web server, which can be exploited by remote attackers to cause a denial of service, resulting in an agent outage. This can ...

4.3CVSS0.01845EPSS
SaveExploits0References3
zdt
zdt
•added 2012/06/01 12:00 a.m.•31 views

MiniWeb Content-Length Denial Of Service

Exploit for windows platform in category dos / poc !/usr/bin/env python miniweb Content-Length DoS PoC Not a 0day, sadly. aluigi found this ages back, I independantly rediscovered it fuzzing and noticed it was still unpatched. Oh well, better disclose so! vuln version at code.google.com/p/miniweb...

7AI score
SaveExploits0
Positive Technologies
Positive Technologies
•added 2012/05/15 12:00 a.m.•26 views

PT-2013-51: Open Redirect Vulnerability in Siemens Simatic WinCC TIA Portal

The specialists of the Positive Research center have detected "Open Redirect" vulnerability in Siemens Simatic WinCC TIA Portal. Open redirect vulnerability in Siemens WinCC TIA Portal allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging...

5.8CVSS6.8AI score0.02067EPSS
SaveExploits0References5
ICS
ICS
•added 2012/04/26 6:00 a.m.•131 views

Siemens WinCC Insecure SQL Server Authentication

Overview Siemens has released a software update for an insecure SQL server authentication vulnerability in Siemens’ SIMATIC WinCC and SIMATIC PCS 7 software. Previous versions of SIMATIC WinCC use default SQL server credentials that allowed administrative access to the database. The default...

7.8CVSS8.2AI score0.0055EPSS
SaveExploits2References10
ICS
ICS
•added 2012/03/10 7:00 a.m.•64 views

Siemens WinCC Multiple Vulnerabilities

Overview Independent researchers Gleb Gritsai, Alexander Zaitsev, Sergey Scherbel, Yuri Goltsev, Dmitry Serebryannikov, Sergey Bobrov, Denis Baranov, Andrey Medov from Positive Technologies have identified multiple vulnerabilities in the Siemens WinCC application. In evaluating these reported...

5.8CVSS7.1AI score0.02328EPSS
SaveExploits0References10
NVD
NVD
•added 2012/02/03 8:55 p.m.•38 views

CVE-2011-4878

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexibl...

7.8CVSS6.6AI score0.11092EPSS
SaveExploits1References8
NVD
NVD
•added 2012/02/03 8:55 p.m.•29 views

CVE-2011-4879

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle UR...

8.5CVSS6.7AI score0.12105EPSS
SaveExploits1References8
NVD
NVD
•added 2012/02/03 8:55 p.m.•35 views

CVE-2011-4508

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication token...

9.3CVSS6.7AI score0.02979EPSS
SaveExploits0References2
NVD
NVD
•added 2012/02/03 8:55 p.m.•31 views

CVE-2011-4509

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account...

10CVSS6.6AI score0.01975EPSS
SaveExploits0References2
NVD
NVD
•added 2012/02/03 8:55 p.m.•33 views

CVE-2011-4510

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

4.3CVSS5.6AI score0.0142EPSS
SaveExploits0References2
NVD
NVD
•added 2012/02/03 8:55 p.m.•39 views

CVE-2011-4512

CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows...

5CVSS6.8AI score0.0161EPSS
SaveExploits0References2
NVD
NVD
•added 2012/02/03 8:55 p.m.•27 views

CVE-2011-4511

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

4.3CVSS5.6AI score0.0142EPSS
SaveExploits0References2
NVD
NVD
•added 2012/02/03 8:55 p.m.•31 views

CVE-2011-4513

Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file,...

10CVSS7.5AI score0.04776EPSS
SaveExploits0References2
NVD
NVD
•added 2012/02/03 8:55 p.m.•36 views

CVE-2011-4875

Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled,...

9.3CVSS7.9AI score0.13841EPSS
SaveExploits1References8
NVD
NVD
•added 2012/02/03 8:55 p.m.•37 views

CVE-2011-4514

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attacker...

10CVSS6.4AI score0.03377EPSS
SaveExploits0References2
NVD
NVD
•added 2012/02/03 8:55 p.m.•39 views

CVE-2011-4876

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is...

9.3CVSS6.7AI score0.09046EPSS
SaveExploits1References9
NVD
NVD
•added 2012/02/03 8:55 p.m.•34 views

CVE-2011-4877

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cau...

7.1CVSS6.5AI score0.07259EPSS
SaveExploits1References8
Prion
Prion
•added 2012/02/03 8:55 p.m.•22 views

Authentication flaw

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication token...

9.3CVSS7.2AI score0.02979EPSS
SaveExploits0References2Affected Software3
Rows per page
Query Builder