Lucene search
+L

1047 matches found

securityvulns
securityvulns
•added 2011/12/05 12:00 a.m.•38 views

Siemens SIMATIC WinCC flexible multiple security vulnerabilities

HmiLoad and miniweb multiple security vulnerabilities...

1.6AI score
SaveExploits0References1Affected Software1
securityvulns
securityvulns
•added 2011/12/05 12:00 a.m.•90 views

Vulnerabilities in Siemens SIMATIC WinCC flexible 2008 SP2

Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2 + security patch 1 Platforms: Windows Bugs: A HmiLoad strings sta...

1.6AI score
SaveExploits0
Exploit DB
Exploit DB
•added 2011/11/28 12:00 a.m.•84 views

Siemens SIMATIC WinCC Flexible (Runtime) - Multiple Vulnerabilities

Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2 + security patch 1 Platforms: Windows Bugs: A HmiLoad strings sta...

9.3CVSS5.2AI score0.13841EPSS
SaveExploits1
exploitpack
exploitpack
•added 2011/11/28 12:00 a.m.•50 views

Siemens SIMATIC WinCC Flexible (Runtime) - Multiple Vulnerabilities

Siemens SIMATIC WinCC Flexible Runtime - Multiple Vulnerabilities Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2...

0.5AI score
SaveExploits0
ThreatPost
ThreatPost
•added 2011/11/22 5:07 p.m.•30 views

Was The Three Character Password Used To Hack South Houston's Water Treatment Plant A Siemens Default?

Siemens said on Tuesday that it is working with the U.S. Department of Homeland Security to investigate a cyber intrusion into a water treatment plant in South Houston, Texas, but couldn’t confirm that a default, three digit password hard coded into an application used to control the company’s...

8.6AI score
SaveExploits0References5
NVD
NVD
•added 2011/09/16 12:35 p.m.•32 views

CVE-2011-3321

Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC TIA Portal Runtime Advanced, allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted packet to TCP...

9.3CVSS8.3AI score0.0707EPSS
SaveExploits0References5
Prion
Prion
•added 2011/09/16 12:35 p.m.•25 views

Heap overflow

Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC TIA Portal Runtime Advanced, allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted packet to TCP...

9.3CVSS9AI score0.0707EPSS
SaveExploits0References5
Cvelist
Cvelist
•added 2011/09/15 9:00 p.m.•43 views

CVE-2011-3321

Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC TIA Portal Runtime Advanced, allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted packet to TCP...

8.3AI score0.0707EPSS
SaveExploits0References5
CVE
CVE
•added 2011/09/15 9:00 p.m.•75 views

CVE-2011-3321

CVE-2011-3321 affects Siemens WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced Loader. The issue is a heap-based buffer overflow in the loader’s handling of inputs on 2308/TCP, enabling remote attackers to cause memory corruption and potentially execute arbitrary code or cau...

9.3CVSS8.6AI score0.0707EPSS
SaveExploits0References5Affected Software2
Positive Technologies
Positive Technologies
•added 2011/09/15 12:00 a.m.•1 views

PT-2011-4389

Name of the Vulnerable Software and Affected Versions Siemens WinCC Runtime Advanced Loader affected versions not specified SIMATIC WinCC flexible Runtime affected versions not specified SIMATIC WinCC TIA Portal Runtime Advanced affected versions not specified Description The issue is related to ...

9.3CVSS0.0707EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2011/09/15 12:00 a.m.•5 views

CVE-2011-3321: Improper Restriction of Operations within the Bounds of a Memory Buffer

Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC TIA Portal Runtime Advanced, allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted packet to TCP...

9.3CVSS6.6AI score0.0707EPSS
SaveExploits0References2
ThreatPost
ThreatPost
•added 2011/06/08 3:57 p.m.•11 views

Many Stuxnet Vulnerabilities Still Unpatched

The media storm over the Stuxnet worm may have passed, but many of the software holes that were used by the worm remain unpatched and leave Siemens customers open to a wide range of potentially damaging cyber attacks, according to industrial control system expert Ralph Langner. Writing on his...

0.4AI score
SaveExploits0References7
ICS
ICS
•added 2011/06/04 6:00 a.m.•49 views

Siemens WinCC Flexible Runtime Heap Overflow

Overview ICS-CERT originally released Advisory ICSA-11-244-01P on the US-CERT secure Portal on September 01, 2011. This web page release was delayed to allow users sufficient time to download and install the update. Independent security researchers Billy Rios and Terry McCorkle have reported a...

9.3CVSS8AI score0.0707EPSS
SaveExploits0References10
ThreatPost
ThreatPost
•added 2011/05/24 3:20 p.m.•18 views

Researcher Says Siemens Downplaying Serious SCADA Holes

Dillon Beresford, the NSS Labs researcher who disclosed serious holes in industrial control system software from Siemens says the company is downplaying the seriousness of the vulnerabilities in its public statements, and that a supposed “fix” for the vulnerabilities is inadequate. In a message...

0.5AI score
SaveExploits0References5
ThreatPost
ThreatPost
•added 2010/12/15 10:06 p.m.•18 views

HP Storage Hardware Harbors Secret Back Door

HP has acknowledged a security issue with storage area networking equipment after reports surfaced about a hard-coded “back door” account. Hewlett Packard said in a statement that it has identified a “potential security issue” with one of its storage area networking SAN products and is readying a...

1.2AI score
SaveExploits0References4
VulnCheck KEV
VulnCheck KEV
•added 2010/10/01 12:00 a.m.•9 views

VulnCheck KEV: CVE-2010-2772

Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568...

7.8CVSS7.1AI score0.0055EPSS
SaveIn wildExploits2References4
ThreatPost
ThreatPost
•added 2010/07/31 4:07 a.m.•28 views

Microsoft to Issue Emergency Patch for Critical Windows Flaw

Microsoft will issue an out-of-band patch on Monday for a critical vulnerability in all of the current versions of Windows. The company didn’t identify which flaw it will be patching, but the description of the vulnerability is a close match to the LNK flaw that attackers have been exploiting for...

0.8AI score
SaveExploits0References6
Cvelist
Cvelist
•added 2010/07/22 10:00 a.m.•62 views

CVE-2010-2772

Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568...

7.5AI score0.0055EPSS
SaveExploits2References14
CVE
CVE
•added 2010/07/22 10:00 a.m.•442 views

CVE-2010-2772

CVE-2010-2772 affects Siemens SIMATIC WinCC and SIMATIC PCS 7: a security bypass via default hard-coded SQL credentials allows remote attackers to access the backend database with administrative-like access. The vulnerability is tied to use of default credentials in the WinCC SQL server, permitti...

7.8CVSS7.2AI score0.0055EPSS
SaveIn wildExploits2References14Affected Software1
NVD
NVD
•added 2010/07/22 5:43 a.m.•57 views

CVE-2010-2772

Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568...

7.8CVSS7.4AI score0.0055EPSS
SaveExploits2References14
Rows per page
Query Builder