1740 matches found
Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module Missing Authentication For Critical Function (CVE-2018-4840)
A vulnerability has been identified in DIGSI 4 All versions V4.92, EN100 Ethernet module DNP3 variant All versions V1.05.00, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.30, EN100 Ethernet module Modbus TCP variant All versions, EN100...
Rockwell Automation 1794-AENT Flex I/O Series B Buffer Copy Without Checking Size of Input (CVE-2020-6085)
An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen- Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a...
Mitsubishi Electric MELSEC-F Series Null Pointer Dereference (CVE-2021-20596)
NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted...
Mitsubishi Electric MELSEC iQ-R Series Exposure of Sensitive Information to an Unauthorized Actor (CVE-2021-20594)
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules R08/16/32/120SFCPU all versions, R08/16/32/120PSFCPU all versions allows a remote unauthenticated attacker to acquire legitimate user names registered in the module via...
Siemens Industrial Products Improper Input Validation (CVE-2017-12741)
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2019-6809)
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 firmware versions prior to V2.90, Modicon M340 firmware versions prior to V3.10, Modicon Premium all versions, Modicon Quantum all versions, which could cause a possible denial of service when reading invalid data from the...
Mitsubishi Electric MELSEC iQ-R Resource Management Errors (CVE-2020-5658)
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...
Siemens SIMATIC, SINUMERIK, and PROFINET IO Improper Input Validation (CVE-2018-4843)
A vulnerability has been identified in SIMATIC CP 343-1 incl. SIPLUS variants All versions, SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP 443-1 Advanced All versions V3.3, SIMATIC ET 200pro IM154-8...
Siemens SIMATIC S7-1200 CPU Family Version 4 Cross-Site Request Forgery (CVE-2018-13800)
A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 All versions V4.2.3. The web interface could allow a Cross-Site Request Forgery CSRF attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a...
VMware OT Asset Information
It is possible to obtain attributes of the remote VMware OT device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc'; include"compat.inc"; if...
Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2020-5666)
Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series CPU Modules R00/01/02CPU Firmware versions from '05' to '19' and R04/08/16/32/120ENCPU Firmware versions from '35' to '51' allows a remote attacker to cause an error in a CPU unit via a specially crafted HTTP packet, which may...
Rockwell Automation ControlLogix controllers Exposure of Sensitive Information to an Unauthorized Actor (CVE-2012-6441)
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules allow remote attackers to obtain sensitive information via a crafted CIP packet. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Schneider Electric Quantum Ethernet Module Hard-Coded Credentials (CVE-2011-4859)
The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771 and 140CPU65 modules, the Premium TSXETY and TSXP57 modules, the M340 BMXNOE01 and BMXP3420 modules, and the STB DIO STBNIC2212 and STBNIP2 modules, uses hardcoded passwords for the 1 AUTCSE, 2 AUTCSE, 3 fdrusers, 4...
Yokogawa Multiple Products Stack-based Buffer Overflow (CVE-2015-5627)
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquant...
Beckhoff TwinCAT RT Network Driver Incomplete Cleanup (CVE-2020-12494)
Beckhoff's TwinCAT RT network driver for Intel 8254x and 8255x is providing EtherCAT functionality. The driver implements real-time features. Except for Ethernet frames sent from real-time functionality, all other Ethernet frames sent through the driver are not padded if their payload is less tha...
Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7543)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...
Siemens EN100 Ethernet Module Relative Path Traversal (CVE-2019-13944)
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
Schneider Electric Modicon Injection (CVE-2020-7475)
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...
Dell OT Asset Information
It is possible to obtain attributes of the remote Dell OT device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc'; include"compat.inc"; if...
Schneider Electric Modicon Open Redirect (CVE-2018-7804)
A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing. This plugin only works with Tenable.ot. Please...