Lucene search
+L

1740 matches found

Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.27 views

Rockwell (CVE-2012-4695) (deprecated)

Plugin deprecated as rslinx is not supported. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable, Inc. @DEPRECATED@ Disabled on 2023/08/03 due to being generated via a catchall regex...

7.6AI score0.02764EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.43 views

Siemens Heap-Based Buffer Overflow in Wind River VxWorks (CVE-2019-12257)

Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

8.8CVSS9.6AI score0.84177EPSS
SaveExploits0References11
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.27 views

Rockwell (CVE-2013-2807) (deprecated)

Plugin deprecated because rslinx is not detectable in this way This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. @DEPRECATED@ Disabled on 2023/03/10. Deprecated because rslinx...

7.6AI score0.03855EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.18 views

Rockwell (CVE-2018-18981) (deprecated)

Plugin deprecated because factorytalk is not detectable in this way This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. @DEPRECATED@ Disabled on 2023/03/10. Deprecated because...

7.6AI score0.03866EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.16 views

Toyota Controller Asset Information

It is possible to obtain attributes of the remote Toyota Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...

5.6AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.19 views

Schneider Electric Modicon Improper Authentication (CVE-2012-0931)

Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors. This plugin only works with Tenable.ot. Please visit...

9.8CVSS7.8AI score0.04922EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.21 views

Siemens SIMATIC S7-1200 CPU Family Version 4 Cross-Site Request Forgery (CVE-2018-13800)

A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 All versions V4.2.3. The web interface could allow a Cross-Site Request Forgery CSRF attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a...

7.3CVSS7.2AI score0.00626EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.28 views

Schneider Electric Quantum Ethernet Module Hard-Coded Credentials (CVE-2011-4859)

The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771 and 140CPU65 modules, the Premium TSXETY and TSXP57 modules, the M340 BMXNOE01 and BMXP3420 modules, and the STB DIO STBNIC2212 and STBNIP2 modules, uses hardcoded passwords for the 1 AUTCSE, 2 AUTCSE, 3 fdrusers, 4...

10CVSS7.4AI score0.03894EPSS
SaveExploits1References8
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.23 views

Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Improper Restriction of Excessive Authentication Attempts (CVE-2017-7898)

An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions;...

9.8CVSS7.4AI score0.05152EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.24 views

Schneider Electric Quantum Ethernet Module Improper Authentication (CVE-2011-4860)

The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device aka the Quantum 140NOE771 module generates the password for the fwupgrade account by performing a calculation on the MAC address, which makes it easier for remote attackers to obtain access via a ...

10CVSS5.8AI score0.02642EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.32 views

Schneider Electric Modicon Exposure of Sensitive Information to an Unauthorized Actor (CVE-2019-6850)

A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module. This plugin only works with...

7.5CVSS7.7AI score0.01709EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.13 views

Beckhoff TwinCAT RT Network Driver Incomplete Cleanup (CVE-2020-12494)

Beckhoff's TwinCAT RT network driver for Intel 8254x and 8255x is providing EtherCAT functionality. The driver implements real-time features. Except for Ethernet frames sent from real-time functionality, all other Ethernet frames sent through the driver are not padded if their payload is less tha...

5.3CVSS5.8AI score0.01014EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.20 views

Siemens EN100 Ethernet Module Relative Path Traversal (CVE-2019-13944)

A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...

5.3CVSS5.6AI score0.016EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.18 views

Schneider Electric Modicon Open Redirect (CVE-2018-7804)

A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing. This plugin only works with Tenable.ot. Please...

6.1CVSS6.4AI score0.00864EPSS
SaveExploits1References2
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.75 views

Rockwell Automation Logix Controllers Insufficiently Protected Credentials (CVE-2021-22681)

Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730,...

9.8CVSS7.6AI score0.6363EPSS
SaveExploits2References5
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.36 views

Siemens SIMATIC, SINUMERIK, and PROFINET IO Improper Input Validation (CVE-2018-4843)

A vulnerability has been identified in SIMATIC CP 343-1 incl. SIPLUS variants All versions, SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP 443-1 Advanced All versions V3.3, SIMATIC ET 200pro IM154-8...

6.5CVSS6.4AI score0.00543EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.845 views

Schneider Electric Modicon Controllers and Software Authentication Bypass By Spoofing (CVE-2021-22779)

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, SCADAPack...

9.1CVSS8.7AI score0.01023EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.20 views

Emerson DeltaV Improper Permissions, Privileges, and Access Controls (CVE-2012-1818)

An unspecified ActiveX control in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to overwrite arbitrary files via unknown vectors. This plugin only works with Tenable.ot. Please visit...

6.4CVSS5.9AI score0.01886EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.12 views

Rockwell Automation Controller Asset Information

It is possible to obtain attributes of the remote Rockwell Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...

5.6AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.30 views

Siemens SIMATIC S7-1500 CPU Improper Input Validation (CVE-2018-16558)

A vulnerability has been identified in SIMATIC S7-1500 CPU All versions = V2.0 and V2.5, SIMATIC S7-1500 CPU All versions = V1.8.5. Specially crafted network packets sent to port 80/tcp or 443/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the device...

7.8CVSS7.1AI score0.01986EPSS
SaveExploits0References3
Rows per page