Mitsubishi Electric MELSEC-F Series Null Pointer Dereference (CVE-2021-20596)

2022-02-0700:00:00
This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
14

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:N/I:N/A:P

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

0.003 Low

EPSS

Percentile

69.2%

NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and system reset is required for recovery.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500538);
  script_version("1.9");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/03/04");

  script_cve_id("CVE-2021-20596");

  script_name(english:"Mitsubishi Electric MELSEC-F Series Null Pointer Dereference (CVE-2021-20596)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14
and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS
condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and
system reset is required for recovery.  

This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
  # https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-006_en.pdf
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?e12e9fa6");
  script_set_attribute(attribute:"see_also", value:"https://jvn.jp/vu/JVNVU94348759/index.html");
  script_set_attribute(attribute:"see_also", value:"https://us-cert.cisa.gov/ics/advisories/icsa-21-201-01");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Mitsubishi Electric Corporation recommends using the newest version of firmware possible. The fixed products and
versions are as follows:

- FX3U-ENET:Firmware Version 1.16 or later
- FX3U-ENET-L:Firmware Version 1.16 or later
- FX3U-ENET-P502:Firmware Version 1.16 or later

To minimize the risk of exploiting this vulnerability, Mitsubishi Electric Corporation recommends users take the
following mitigations:

- Use a firewall or virtual private network (VPN), etc., to prevent unauthorized access when Internet access is
required.
- Use within a LAN and block access from untrusted networks and hosts through firewalls.

Please refer to the Mitsubishi Electric advisory for further details.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-20596");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(476);

  script_set_attribute(attribute:"vuln_publication_date", value:"2021/07/22");
  script_set_attribute(attribute:"patch_publication_date", value:"2021/07/22");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:mitsubishielectric:fx3u-enet-l_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:mitsubishielectric:fx3u-enet-p502_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:mitsubishielectric:fx3u-enet_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Mitsubishi");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Mitsubishi');

var asset = tenable_ot::assets::get(vendor:'Mitsubishi');

var vuln_cpes = {
    "cpe:/o:mitsubishielectric:fx3u-enet-l_firmware" :
        {"versionEndIncluding" : "1.14", "family" : "MELSECFCP"},
    "cpe:/o:mitsubishielectric:fx3u-enet-p502_firmware" :
        {"versionEndIncluding" : "1.14", "family" : "MELSECFCP"},
    "cpe:/o:mitsubishielectric:fx3u-enet_firmware" :
        {"versionEndIncluding" : "1.14", "family" : "MELSECFCP"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
mitsubishielectricfx3u-enet-l_firmwarecpe:/o:mitsubishielectric:fx3u-enet-l_firmware
mitsubishielectricfx3u-enet-p502_firmwarecpe:/o:mitsubishielectric:fx3u-enet-p502_firmware
mitsubishielectricfx3u-enet_firmwarecpe:/o:mitsubishielectric:fx3u-enet_firmware

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:N/I:N/A:P

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

0.003 Low

EPSS

Percentile

69.2%

Related for TENABLE_OT_MITSUBISHI_CVE-2021-20596.NASL