The vulnerability of the Modbus TCP protocol implementation in microprogrammed software for programmable logic controllers from Schneider Electric, such as Modicon M340, M580, MC80, Modicon Momentum MDI, Legacy Modicon Quantum/Premium, allows a intruder to trigger a service failure.
The vulnerability of the Modbus TCP protocol implementation in microprogrammed logic controllers from Schneider Electric, such as Modicon M340, M580, MC80, Modicon Momentum MDI, and Legacy Modicon Quantum/Premium, is related to a potential integer overflow. Exploiting this vulnerability could all...
The vulnerability of the programming software for PLCs (programmable logic controllers), EcoStruxure Control Expert, and the automation systems for technological processes, EcoStruxure Process Expert. This vulnerability relates to the lack of a password recovery mechanism, allowing attackers to gain read/write access via the Modbus protocol.
The vulnerabilities of the programming software for PLCs programmable logic controllers, the EcoStruxure Control Expert system for automating technological processes, and the micro-programming software for programmable logic controllers—such as Schneider Electric Modicon M340 and M580—are related...
PT-2022-4155 · Schneider Electric · Modicon Quantum/Premium +4
Name of the Vulnerable Software and Affected Versions: Modicon M340 CPU versions V3.40 and prior Modicon M580 CPU versions V3.22 and prior Legacy Modicon Quantum/Premium All Versions Modicon Momentum MDI 171CBU All Versions Modicon MC80 BMKC80 versions V1.7 and prior Description: A CWE-191: Integ...
PT-2022-4153 · Schneider Electric · Legacy Modicon Quantum +5
Name of the Vulnerable Software and Affected Versions: Modicon M340 CPU versions prior to V3.30 Modicon M580 CPU versions prior to SV3.20 Modicon MC80 versions prior to V1.6 Modicon M580 CPU Safety version all Modicon Momentum MDI versions prior to V2.3 Legacy Modicon Quantum version all...
多款Schneider Electric产品数据伪造问题漏洞
The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...
The vulnerability of the programming software simulator PLC EcoStruxure Control Expert, the automation system ProcessExpert, the configuration software SCADAPack RemoteConnect, and the micro-software for programmable logic controllers Modicon M580 and Modicon M340 relates to the bypassing of authentication procedures. This allows a perpetrator to gain access in read-only and write mode.
The vulnerabilities of the EcoStruxure Control Expert programming tool, the ProcessExpert automation system, the SCADAPack RemoteConnect configuration tool, and the Modicon M580 and Modicon M340 programmable logic controllers are related to the ability to bypass authentication through spoofing...
Schneider Electric Modicon Out-of-bounds Read (CVE-2021-22790)
A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU part numbers BMEP and BMEH, all versions, Modicon M340 CPU part...
Schneider Electric Modicon Controllers Improper Check For Unusual or Exceptional Conditions (CVE-2019-6856)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium see security notification for specific versions which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2019-6806)
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus. This plugin only works with Tenable.ot. Please...
Schneider Electric Modicon Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2018-7838)
A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FT...
Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6846)
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause information disclosure when using the FTP protocol. This plugin only works with Tenable.ot. Please visit...
Schneider Electric Modicon Controllers Use of Insufficiently Random Values (CVE-2019-6821)
CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum. This plugin only works...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2018-7857)
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus. This plugin only works with Tenable.ot...
Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7537)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...
Schneider Electric Web Server on Modicon M340 Out-of-Bounds Read (CVE-2020-7562)
A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file ...
Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6845)
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum all firmware versions, which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. This...
Schneider Electric Modicon Controllers Improper Check For Unusual or Exceptional Conditions (CVE-2018-7794)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium see security notification for specific versions which could cause a Denial of Service when reading data with invalid index using Modbus TCP. This...
Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6848)
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU BMEx58 and Modicon M580 communication module BMENOC0311, BMENOC0321 see notification for version info, which could cause a Denial of Service attack on the PLC when sending specific data on the REST API...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2018-7849)
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus. This plugin only works with...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2019-6828)
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 firmware version prior to V2.90, Modicon M340 firmware version prior to V3.10, Modicon Premium all versions, and Modicon Quantum all versions, which could cause a possible denial of service when reading specific coils and registers i...