CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
NONE
Availability Impact
NONE
AV:N/AC:M/Au:N/C:P/I:N/A:N
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
NONE
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
AI Score
Confidence
High
EPSS
Percentile
52.3%
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##
include('deprecated_nasl_level.inc');
include('compat.inc');
if (description)
{
script_id(500240);
script_version("1.8");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/24");
script_cve_id("CVE-2019-6846");
script_name(english:"Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6846)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A CWE-319: Cleartext Transmission of Sensitive Information
vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and
140CRA modules (all firmware versions), which could cause information
disclosure when using the FTP protocol.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
# https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-281-02
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?844a65fe");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:P/I:N/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-6846");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(319);
script_set_attribute(attribute:"vuln_publication_date", value:"2019/10/29");
script_set_attribute(attribute:"patch_publication_date", value:"2019/10/29");
script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_140cra_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_bmxcra_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_series_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Schneider");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Schneider');
var asset = tenable_ot::assets::get(vendor:'Schneider');
var vuln_cpes = {
"cpe:/o:schneider-electric:modicon_m580_series_firmware" :
{"versionEndExcluding" : "4.10", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m340_series_firmware" :
{"versionEndExcluding" : "3.50", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_bmxcra_firmware" :
{"family" : "Concept"},
"cpe:/o:schneider-electric:modicon_140cra_firmware" :
{"family" : "Concept"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
NONE
Availability Impact
NONE
AV:N/AC:M/Au:N/C:P/I:N/A:N
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
NONE
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
AI Score
Confidence
High
EPSS
Percentile
52.3%