Lucene search
+L

424 matches found

Prion
Prion
added 2023/01/30 1:15 p.m.27 views

Design/Logic Flaw

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...

7.5CVSS9.5AI score0.01173EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2023/01/30 12:00 a.m.14 views

CVE-2022-45788

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...

7.5CVSS9.6AI score0.01173EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2023/01/30 12:00 a.m.52 views

CVE-2022-45788

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...

7.5CVSS9.7AI score0.01173EPSS
SaveExploits0References1
ICS
ICS
added 2023/01/10 12:00 a.m.79 views

Schneider Electric EcoStruxure Control Expert, Process Expert, Modicon M340, M580 and M580 CPU (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Schneider Electric Equipment: EcoStruxure Control Expert, EcoStruxure Process Expert, Modicon M340 CPU, Modicon M580 CPU, Modicon Momentum Unity M1E Processor, Modicon MC80 Vulnerability: Authentication Bypass by...

9.8CVSS7.5AI score0.01455EPSS
SaveExploits0References11
Positive Technologies
Positive Technologies
added 2023/01/10 12:00 a.m.8 views

PT-2023-1079 · Schneider Electric · Modicon M580 Cpu +7

Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert All Versions EcoStruxure Process Expert All Versions Modicon M340 CPU - part numbers BMXP34 All Versions Modicon M580 CPU - part numbers BMEP and BMEH All Versions Modicon M580 CPU Safety - part numbers BMEP58S and...

9.8CVSS9.7AI score0.01173EPSS
SaveExploits0References10
Positive Technologies
Positive Technologies
added 2023/01/10 12:00 a.m.9 views

PT-2023-1236 · Schneider Electric · Ecostruxure Process Expert +4

Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert versions prior to V2020 EcoStruxure Process Expert versions prior to V2020 Modicon M340 CPU versions prior to the latest version Modicon M580 CPU versions prior to the latest version Modicon M580 CPU Safety versions...

9.8CVSS9.3AI score0.01455EPSS
SaveExploits0References10
Tenable Nessus
Tenable Nessus
added 2022/12/07 12:00 a.m.30 views

Schneider Electric Modicon Integer Underflow (CVE-2022-37301)

A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...

7.5CVSS7.3AI score0.00708EPSS
SaveExploits0References2
NVD
NVD
added 2022/11/22 12:15 p.m.37 views

CVE-2022-37301

A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...

7.5CVSS0.00708EPSS
SaveExploits0References1
Prion
Prion
added 2022/11/22 12:15 p.m.23 views

Integer overflow

A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...

5CVSS7.4AI score0.00708EPSS
SaveExploits0References1Affected Software30
Vulnrichment
Vulnrichment
added 2022/11/22 12:00 a.m.7 views

CVE-2022-37301

A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...

7.5CVSS7.4AI score0.00708EPSS
SaveExploits0References1
CVE
CVE
added 2022/11/22 12:00 a.m.79 views

CVE-2022-37301

CVE-2022-37301 is an integer underflow (wraparound) vulnerability in Schneider Electric Modicon Modbus TCP handling that can cause DoS via memory access violations. Affected: Modicon M340 CPU BMXP34* (V3.40 and prior); M580 CPU BMEP*/BMEH* (V3.22 and prior); Legacy Modicon Quantum/Premium (all ve...

7.5CVSS7.4AI score0.00708EPSS
SaveExploits0References1Affected Software1
Tenable Nessus
Tenable Nessus
added 2022/09/15 12:00 a.m.38 views

Schneider Electric Modicon Weak Password Recovery Mechanism for Forgotten Password (CVE-2022-37300)

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...

9.8CVSS8.3AI score0.00687EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2022/09/12 6:15 p.m.6 views

CVE-2022-37300

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...

9.8CVSS5.8AI score0.00687EPSS
SaveExploits0References2
OSV
OSV
added 2022/09/12 6:15 p.m.8 views

CVE-2022-37300

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...

9.8CVSS5.8AI score0.00687EPSS
SaveExploits0References1
NVD
NVD
added 2022/09/12 6:15 p.m.47 views

CVE-2022-37300

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...

9.8CVSS0.00687EPSS
SaveExploits0References1
Prion
Prion
added 2022/09/12 6:15 p.m.25 views

Design/Logic Flaw

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...

7.5CVSS9.1AI score0.00687EPSS
SaveExploits0References1Affected Software36
Cvelist
Cvelist
added 2022/09/12 5:40 p.m.53 views

CVE-2022-37300

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...

9.8CVSS9.5AI score0.00687EPSS
SaveExploits0References1
CVE
CVE
added 2022/09/12 5:40 p.m.96 views

CVE-2022-37300

CVE-2022-37300 is a CWE-640 weakness (Weak Password Recovery Mechanism) that could allow unauthorized read/write access to Schneider Electric controllers over Modbus. Affected products and versions include EcoStruxure Control Expert (Unity Pro lineage) up to V15.0 SP1, EcoStruxure Process Expert ...

9.8CVSS9.1AI score0.00687EPSS
SaveExploits0References1Affected Software2
CNNVD
CNNVD
added 2022/09/12 12:00 a.m.11 views

多款Schneider Electric产品授权问题漏洞

Schneider Electric EcoStruxure Control Expert formerly Unity Pro and Schneider Electric EcoStruxure Process Expert are both products of Schneider Electric, a French company. Schneider Electric EcoStruxure Control Expert is a suite of programming software for Schneider Electric logic controller...

9.8CVSS8.4AI score0.00687EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2022/08/15 12:00 a.m.31 views

The vulnerability of the Modbus TCP protocol implementation in microprogrammed software for programmable logic controllers from Schneider Electric, such as Modicon M340, M580, MC80, Modicon Momentum MDI, Legacy Modicon Quantum/Premium, allows a intruder to trigger a service failure.

The vulnerability of the Modbus TCP protocol implementation in microprogrammed logic controllers from Schneider Electric, such as Modicon M340, M580, MC80, Modicon Momentum MDI, and Legacy Modicon Quantum/Premium, is related to a potential integer overflow. Exploiting this vulnerability could all...

7.8CVSS7.3AI score0.00708EPSS
SaveExploits0References2Affected Software2
Rows per page
Query Builder