424 matches found
Design/Logic Flaw
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...
CVE-2022-45788
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...
CVE-2022-45788
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...
Schneider Electric EcoStruxure Control Expert, Process Expert, Modicon M340, M580 and M580 CPU (Update A)
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Schneider Electric Equipment: EcoStruxure Control Expert, EcoStruxure Process Expert, Modicon M340 CPU, Modicon M580 CPU, Modicon Momentum Unity M1E Processor, Modicon MC80 Vulnerability: Authentication Bypass by...
PT-2023-1079 · Schneider Electric · Modicon M580 Cpu +7
Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert All Versions EcoStruxure Process Expert All Versions Modicon M340 CPU - part numbers BMXP34 All Versions Modicon M580 CPU - part numbers BMEP and BMEH All Versions Modicon M580 CPU Safety - part numbers BMEP58S and...
PT-2023-1236 · Schneider Electric · Ecostruxure Process Expert +4
Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert versions prior to V2020 EcoStruxure Process Expert versions prior to V2020 Modicon M340 CPU versions prior to the latest version Modicon M580 CPU versions prior to the latest version Modicon M580 CPU Safety versions...
Schneider Electric Modicon Integer Underflow (CVE-2022-37301)
A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...
CVE-2022-37301
A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...
Integer overflow
A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...
CVE-2022-37301
A CWE-191: Integer Underflow Wrap or Wraparound vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU part numbers BMXP34V3.40 and prior, Modicon M580 CPU part numbers BME...
CVE-2022-37301
CVE-2022-37301 is an integer underflow (wraparound) vulnerability in Schneider Electric Modicon Modbus TCP handling that can cause DoS via memory access violations. Affected: Modicon M340 CPU BMXP34* (V3.40 and prior); M580 CPU BMEP*/BMEH* (V3.22 and prior); Legacy Modicon Quantum/Premium (all ve...
Schneider Electric Modicon Weak Password Recovery Mechanism for Forgotten Password (CVE-2022-37300)
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...
CVE-2022-37300
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...
CVE-2022-37300
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...
CVE-2022-37300
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...
Design/Logic Flaw
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...
CVE-2022-37300
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions former name of...
CVE-2022-37300
CVE-2022-37300 is a CWE-640 weakness (Weak Password Recovery Mechanism) that could allow unauthorized read/write access to Schneider Electric controllers over Modbus. Affected products and versions include EcoStruxure Control Expert (Unity Pro lineage) up to V15.0 SP1, EcoStruxure Process Expert ...
多款Schneider Electric产品授权问题漏洞
Schneider Electric EcoStruxure Control Expert formerly Unity Pro and Schneider Electric EcoStruxure Process Expert are both products of Schneider Electric, a French company. Schneider Electric EcoStruxure Control Expert is a suite of programming software for Schneider Electric logic controller...
The vulnerability of the Modbus TCP protocol implementation in microprogrammed software for programmable logic controllers from Schneider Electric, such as Modicon M340, M580, MC80, Modicon Momentum MDI, Legacy Modicon Quantum/Premium, allows a intruder to trigger a service failure.
The vulnerability of the Modbus TCP protocol implementation in microprogrammed logic controllers from Schneider Electric, such as Modicon M340, M580, MC80, Modicon Momentum MDI, and Legacy Modicon Quantum/Premium, is related to a potential integer overflow. Exploiting this vulnerability could all...