31 matches found
Rockwell FactoryTalk Activation Manager <= 5.02 Privilege Escalation (SD1799)
The version of Rockwell FactoryTalk Activation Manager installed on the remote Windows host is 5.02 or prior. It is, therefore, affected by a privilege escalation vulnerability. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM...
CVE-2026-16675
A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows...
CVE-2026-16675
A privilege escalation vulnerability exists in Rockwell Automation FactoryTalk® Activation Manager . The root cause is custom installer actions that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker holding valid Windo...
EUVD-2026-69128
A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows...
CVE-2026-16675 Rockwell Automation FactoryTalk® Activation Manager - Privilege Escalation
A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows...
PT-2026-84216
Name of the Vulnerable Software and Affected Versions FactoryTalk Activation Manager affected versions not specified Description A privilege escalation issue exists due to custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repa...
EUVD-2025-27250
Malicious code in bioql PyPI...
CVE-2025-7970
A security issue exists within FactoryTalk Activation Manager. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise...
Rockwell Automation FactoryTalk Activation Manager Data Exposure Vulnerability
Rockwell Automation is a leading global provider of industrial automation and control solutions focused on helping companies achieve smart manufacturing and digital transformation. A data disclosure vulnerability exists in Rockwell Automation FactoryTalk Activation Manager, which can be exploited...
Rockwell FactoryTalk Activation Manager 5.x < 5.02 Information Disclosure
The version of Rockwell FactoryTalk Activation Manager installed on the remote Windows host is 5.x prior to 5.02. It is, therefore, affected by an information disclosure vulnerability. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. Thi...
CVE-2025-7970 Rockwell Automation FactoryTalk Activation Manager Lack of Encryption Vulnerability
A security issue exists within FactoryTalk Activation Manager. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise...
CVE-2025-7970
CVE-2025-7970 affects Rockwell Automation’s FactoryTalk Activation Manager. The connected sources describe a cryptography implementation error that could allow an attacker to decrypt traffic, leading to data exposure, session hijacking, or full network communication compromise. Public disclosures...
CVE-2025-7970 Rockwell Automation FactoryTalk Activation Manager Lack of Encryption Vulnerability
A security issue exists within FactoryTalk Activation Manager. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise...
CISA Releases Fourteen Industrial Control Systems Advisories
CISA released fourteen Industrial Control Systems ICS advisories on September 9, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-252-01 Rockwell Automation ThinManager ICSA-25-252-02 ABB Cylon Aspect BMS/BAS...
Rockwell Automation FactoryTalk Activation Manager
RISK EVALUATION Successful exploitation of this vulnerability could result in in data exposure, session hijacking, or full communication compromise. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:...
PT-2025-36728
Name of the Vulnerable Software and Affected Versions: FactoryTalk Activation Manager affected versions not specified Description: A security issue exists within FactoryTalk Activation Manager related to a flaw in the implementation of cryptography. This could allow attackers to decrypt network...
Rockwell Automation FactoryTalk Activation Manager 安全漏洞
Rockwell Automation is a leading global provider of industrial automation and control solutions focused on helping companies achieve smart manufacturing and digital transformation. A data disclosure vulnerability exists in Rockwell Automation FactoryTalk Activation Manager, which can be exploited...
Rockwell FactoryTalk Activation Manager < 5.01 RCE
The version of Rockwell FactoryTalk Activation Manager installed on the remote Windows host is prior to 5.01. It is, therefore, affected by a vulnerability. - Rockwell Automation FactoryTalk Activation Manager and Studio 5000 Logix Designer uses the affected Wibu-Systems' products which internall...
Rockwell FactoryTalk Activation Manager Installed (Windows)
Binary data rockwellfactorytalkactivationmanagerwininstalled.nbin...
Rockwell FactoryTalk Activation Manager < 4.02 XSS
The version of Rockwell FactoryTalk Activation Manager installed on the remote Windows host is prior to 4.02. It is, therefore, affected by a vulnerability. - A Cross-Site Scripting XSS vulnerability was found in certain versions of Wibu-Systems CodeMeter that may allow local attackers to inject...