Lucene search

K
nessusThis script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.ROCKWELL_FACTORYTALK_ACTIVATION_MANAGER_4_02_CVE-2015-8277.NASL
HistoryJan 22, 2024 - 12:00 a.m.

Rockwell FactoryTalk Activation Manager < 4.02 Buffer Overflow

2024-01-2200:00:00
This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
5
rockwell
factorytalk
activation manager
windows
vulnerability
flexnet publisher
buffer overflow
cve-2015-8277
nessus scanner

10 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:C/I:C/A:C

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

9.7 High

AI Score

Confidence

High

0.916 High

EPSS

Percentile

98.9%

The version of Rockwell FactoryTalk Activation Manager installed on the remote Windows host is prior to 4.02. It is, therefore, affected by a vulnerability.

  • A custom string copying function of the license server manager in FlexNet Publisher does not use proper bounds checking on incoming data, allowing a remote, unauthenticated user to send crafted messages with the intent of causing a buffer overflow. (CVE-2015-8277)

Note that Nessus has not tested for this issue but has instead relied only on the application’s self-reported version number.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(189290);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/23");

  script_cve_id("CVE-2015-8277");
  script_xref(name:"ICSA", value:"18-102-02");

  script_name(english:"Rockwell FactoryTalk Activation Manager < 4.02 Buffer Overflow");

  script_set_attribute(attribute:"synopsis", value:
"An application installed on the remote Windows host is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"The version of Rockwell FactoryTalk Activation Manager installed on the remote Windows host is prior to 4.02. It is, therefore, affected by a
vulnerability.

  - A custom string copying function of the license server manager in FlexNet
    Publisher does not use proper bounds checking on incoming data, allowing a
    remote, unauthenticated user to send crafted messages with the intent of
    causing a buffer overflow. (CVE-2015-8277)

Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version
number.");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-18-102-02");
  script_set_attribute(attribute:"solution", value:
"Upgrade to Rockwell FactoryTalk Activation Manager version 4.02 or later or refer to vendor advisory.");
  script_set_attribute(attribute:"agent", value:"windows");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2015-8277");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");

  script_set_attribute(attribute:"vuln_publication_date", value:"2020/10/02");
  script_set_attribute(attribute:"patch_publication_date", value:"2018/01/01");
  script_set_attribute(attribute:"plugin_publication_date", value:"2024/01/22");

  script_set_attribute(attribute:"plugin_type", value:"local");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:rockwellautomation:factorytalk_activation");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"SCADA");

  script_copyright(english:"This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("rockwell_factorytalk_activation_manager_win_installed.nbin");
  script_require_keys("installed_sw/Rockwell FactoryTalk Activation Manager");

  exit(0);
}

include('vcf.inc');

var app_info = vcf::get_app_info(app:'Rockwell FactoryTalk Activation Manager', win_local:TRUE);

var constraints = [
  {'max_version' : '4.00', 'fixed_display' : '4.02' }
];

vcf::check_version_and_report(app_info:app_info, constraints:constraints, severity:SECURITY_HOLE);
VendorProductVersionCPE
rockwellautomationfactorytalk_activationcpe:/a:rockwellautomation:factorytalk_activation

10 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:C/I:C/A:C

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

9.7 High

AI Score

Confidence

High

0.916 High

EPSS

Percentile

98.9%

Related for ROCKWELL_FACTORYTALK_ACTIVATION_MANAGER_4_02_CVE-2015-8277.NASL