Lucene search

K
nessusThis script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.ROCKWELL_FACTORYTALK_ACTIVATION_MANAGER_4_02_CVE-2017-13754.NASL
HistoryJan 22, 2024 - 12:00 a.m.

Rockwell FactoryTalk Activation Manager < 4.02 XSS

2024-01-2200:00:00
This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
4
rockwell
factorytalk
activation manager
windows
vulnerability
xss
wibu-systems codemeter
cve-2017-13754
configuration file
web script
html
local attackers
sensitive information.

3.5 Low

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

SINGLE

Confidentiality Impact

NONE

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:M/Au:S/C:N/I:P/A:N

5.4 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

5.4 Medium

AI Score

Confidence

High

0.005 Low

EPSS

Percentile

76.1%

The version of Rockwell FactoryTalk Activation Manager installed on the remote Windows host is prior to 4.02. It is, therefore, affected by a vulnerability.

  • A Cross-Site Scripting (XSS) vulnerability was found in certain versions of Wibu-Systems CodeMeter that may allow local attackers to inject arbitrary web script or HTML via a specific field in a configuration file, allowing an attacker to access sensitive information, or even rewrite the content of the HTML page. (CVE-2017-13754)

Note that Nessus has not tested for this issue but has instead relied only on the application’s self-reported version number.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(189288);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/23");

  script_cve_id("CVE-2017-13754");
  script_xref(name:"ICSA", value:"18-102-02");

  script_name(english:"Rockwell FactoryTalk Activation Manager < 4.02 XSS");

  script_set_attribute(attribute:"synopsis", value:
"An application installed on the remote Windows host is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"The version of Rockwell FactoryTalk Activation Manager installed on the remote Windows host is prior to 4.02. It is, therefore, affected by a
vulnerability.

  - A Cross-Site Scripting (XSS) vulnerability was found in certain versions
    of Wibu-Systems CodeMeter that may allow local attackers to inject arbitrary
    web script or HTML via a specific field in a configuration file, allowing an
    attacker to access sensitive information, or even rewrite the content of the
    HTML page. (CVE-2017-13754)

Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version
number.");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-18-102-02");
  script_set_attribute(attribute:"solution", value:
"Upgrade to Rockwell FactoryTalk Activation Manager version 4.02 or later or refer to vendor advisory.");
  script_set_attribute(attribute:"agent", value:"windows");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:S/C:N/I:P/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2017-13754");

  script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"true");

  script_set_attribute(attribute:"vuln_publication_date", value:"2020/10/02");
  script_set_attribute(attribute:"patch_publication_date", value:"2018/01/01");
  script_set_attribute(attribute:"plugin_publication_date", value:"2024/01/22");

  script_set_attribute(attribute:"plugin_type", value:"local");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:rockwellautomation:factorytalk_activation");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"SCADA");

  script_copyright(english:"This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("rockwell_factorytalk_activation_manager_win_installed.nbin");
  script_require_keys("installed_sw/Rockwell FactoryTalk Activation Manager");

  exit(0);
}

include('vcf.inc');

var app_info = vcf::get_app_info(app:'Rockwell FactoryTalk Activation Manager', win_local:TRUE);

var constraints = [
  {'min_version' : '4.00', 'fixed_version' : '4.02' }
];

vcf::check_version_and_report(app_info:app_info, constraints:constraints, severity: SECURITY_NOTE, flags:{xss:TRUE});
VendorProductVersionCPE
rockwellautomationfactorytalk_activationcpe:/a:rockwellautomation:factorytalk_activation

3.5 Low

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

SINGLE

Confidentiality Impact

NONE

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:M/Au:S/C:N/I:P/A:N

5.4 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

5.4 Medium

AI Score

Confidence

High

0.005 Low

EPSS

Percentile

76.1%

Related for ROCKWELL_FACTORYTALK_ACTIVATION_MANAGER_4_02_CVE-2017-13754.NASL