An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arbitrary programs via a crafted HTML document in conjunction with a Login Client button click.
7.2AI Score
0.649EPSS
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect...
8.6CVSS
8.3AI Score
0.001EPSS
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.
7.5CVSS
7.4AI Score
0.001EPSS
Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.
9.8CVSS
9.5AI Score
0.005EPSS
Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.
9.8CVSS
9.4AI Score
0.005EPSS
Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.
9.8CVSS
9.4AI Score
0.064EPSS
Mitsubishi Electric Europe B.V. SmartRTU devices allow remote attackers to obtain sensitive information (directory listing and source code) via a direct request to the /web URI.
7.5CVSS
7.3AI Score
0.041EPSS
Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php.
6.1CVSS
6AI Score
0.001EPSS
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application i...
5.5CVSS
5.3AI Score
0.001EPSS
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files.
5.5CVSS
5.4AI Score
0.001EPSS
In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.
7.5CVSS
7.4AI Score
0.001EPSS
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L0...
5.9CVSS
5.7AI Score
0.002EPSS
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords...
6.5CVSS
6.7AI Score
0.001EPSS
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with f...
9.8CVSS
9.7AI Score
0.005EPSS
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwor...
7.5CVSS
7.7AI Score
0.028EPSS
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to st...
5.4CVSS
5.8AI Score
0.001EPSS
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on...
9.8CVSS
9.7AI Score
0.006EPSS
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin ...
9.8CVSS
9.9AI Score
0.005EPSS
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the...
9.8CVSS
10AI Score
0.011EPSS
Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stac...
7.5CVSS
7.5AI Score
0.001EPSS
A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Ele...
9.8CVSS
9.7AI Score
0.022EPSS
A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9...
7.5CVSS
7.4AI Score
0.003EPSS
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS ...
9.8CVSS
9.6AI Score
0.04EPSS
A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroke...
9.1CVSS
9.5AI Score
0.005EPSS
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9...
7.5CVSS
7.3AI Score
0.003EPSS
Mitsubishi MELSEC iQ-R Series PLCs with firmware 33 allow attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, because this denial of service attack consumes excessive CPU time. After halting, physical access to the PLC is required in order to rest...
7.5CVSS
7.3AI Score
0.003EPSS
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to...
9.8CVSS
7.8AI Score
0.002EPSS
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
9.8CVSS
9.2AI Score
0.003EPSS
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
9.8CVSS
9.5AI Score
0.01EPSS
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
9.8CVSS
9.5AI Score
0.005EPSS
Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to resto...
7.5CVSS
7.2AI Score
0.001EPSS
When MELSOFT transmission port (UDP/IP) of Mitsubishi Electric MELSEC iQ-R series (all versions), MELSEC iQ-F series (all versions), MELSEC Q series (all versions), MELSEC L series (all versions), and MELSEC F series (all versions) receives massive amount of data via unspecified vectors, resource c...
7.5CVSS
7.5AI Score
0.001EPSS
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Eth...
9.8CVSS
9AI Score
0.013EPSS
Buffer error vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
9.8CVSS
9.3AI Score
0.009EPSS
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier does not properly manage sessions, which allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
9.8CVSS
9.3AI Score
0.013EPSS
Null Pointer Dereference vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
9.8CVSS
9.3AI Score
0.012EPSS
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to bypass access restriction and to stop the network functions or execute malware via a specially crafted packet.
9.8CVSS
9.3AI Score
0.009EPSS
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows an attacker on the same network segment to stop the network functio...
8.8CVSS
8.6AI Score
0.001EPSS
Resource Management Errors vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
9.8CVSS
9.3AI Score
0.013EPSS
Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
9.8CVSS
9AI Score
0.005EPSS
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a buffer overflow vulnerability, which may allow a remote attacker to stop the network functions of the products or execut...
9.8CVSS
9.5AI Score
0.01EPSS
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) does not properly manage sessions, which may allow a remote attacker to stop the network functions of the products or execute a mal...
7.5CVSS
7.5AI Score
0.002EPSS
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a null pointer dereference vulnerability, which may allow a remote attacker to stop the network functions of the products ...
7.5CVSS
7.5AI Score
0.002EPSS
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains an improper access control vulnerability, which may which may allow a remote attacker tobypass access restriction and stop...
7.5CVSS
7.6AI Score
0.002EPSS
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains an improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability, which may allow a rem...
9.8CVSS
9.3AI Score
0.003EPSS
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a resource management error vulnerability, which may allow a remote attacker to stop the network functions of the products...
7.5CVSS
7.5AI Score
0.002EPSS
Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and ear...
7.5CVSS
7.2AI Score
0.002EPSS
Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. ...
7.5CVSS
7.1AI Score
0.001EPSS
Buffer overflow vulnerability in TCP/IP function included in the firmware of GT14 Model of GOT 1000 series (GT1455-QTBDE CoreOS version "05.65.00.BD" and earlier, GT1450-QMBDE CoreOS version "05.65.00.BD" and earlier, GT1450-QLBDE CoreOS version "05.65.00.BD" and earlier, GT1455HS-QTBDE CoreOS vers...
9.8CVSS
9.4AI Score
0.006EPSS
Session fixation vulnerability in TCP/IP function included in the firmware of GT14 Model of GOT 1000 series (GT1455-QTBDE CoreOS version "05.65.00.BD" and earlier, GT1450-QMBDE CoreOS version "05.65.00.BD" and earlier, GT1450-QLBDE CoreOS version "05.65.00.BD" and earlier, GT1455HS-QTBDE CoreOS ver...
7.5CVSS
7.4AI Score
0.005EPSS