Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, una...
7.5CVSS
7.5AI Score
0.005EPSS
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally.
7.5CVSS
7.6AI Score
0.004EPSS
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally.
7.5CVSS
7.6AI Score
0.004EPSS
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated att...
7.5CVSS
7.5AI Score
0.01EPSS
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a res...
9.1CVSS
9AI Score
0.007EPSS
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
7.5CVSS
7.8AI Score
0.004EPSS
Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauth...
6.5CVSS
6.5AI Score
0.006EPSS
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally.
6.8CVSS
6.5AI Score
0.006EPSS
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file inc...
7.8CVSS
7.8AI Score
0.001EPSS
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file inc...
7.8CVSS
7.8AI Score
0.001EPSS
Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a mon...
7.8CVSS
7.8AI Score
0.001EPSS
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENE...
9.8CVSS
9.6AI Score
0.006EPSS
Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially cr...
9.1CVSS
8.9AI Score
0.004EPSS
Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file...
7.8CVSS
7.8AI Score
0.001EPSS
Cleartext Transmission of Sensitive Information vulnerability due to the use of Basic Authentication for HTTP connections in Mitsubishi Electric consumer electronics products (PHOTOVOLTAIC COLOR MONITOR ECO-GUIDE, HEMS adapter, Wi-Fi Interface, Air Conditioning, Induction hob, Mitsubishi Electric H...
9.8CVSS
9.3AI Score
0.005EPSS
Cross-site scripting vulnerability in Mitsubishi Electric consumer electronics products (Air Conditioning, Wi-Fi Interface, Refrigerator, HEMS adapter, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator,...
6.1CVSS
6.3AI Score
0.002EPSS
Active Debug Code vulnerability in robot controller of Mitsubishi Electric Corporation industrial robot MELFA SD/SQ Series and MELFA F-Series allows a remote unauthenticated attacker to gain unauthorized access by authentication bypass through an unauthorized telnet login. As for the affected model...
7.5CVSS
8AI Score
0.001EPSS
Improper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version "65" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware version "65" and prior allows a remote unauthenticated attacker t...
8.6CVSS
7.6AI Score
0.002EPSS
Improper Input Validation vulnerability in Mitsubishi Electric GOT2000 Series GT27 model FTP server versions 01.39.000 and prior, Mitsubishi Electric GOT2000 Series GT25 model FTP server versions 01.39.000 and prior and Mitsubishi Electric GOT2000 Series GT23 model FTP server versions 01.39.000 and...
6.5CVSS
6.1AI Score
0.002EPSS
Predictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xM...
9.1CVSS
9.2AI Score
0.004EPSS
Improper Restriction of Rendered UI Layers or Frames vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT SoftGOT20...
6.1CVSS
4.8AI Score
0.001EPSS
Authentication Bypass by Spoofing vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT SoftGOT2000 versions 1.265B ...
8.1CVSS
7.7AI Score
0.003EPSS
Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server.
7.5CVSS
7.5AI Score
0.002EPSS
Weak Encoding for Password vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.49.000 and prior, GT25 model versions 01.49.000 and prior, GT23 model versions 01.49.000 and prior, GT21 model versions 01.49.000 and prior, GOT SIMPLE Series GS25 model versions 01.49....
7.5CVSS
7.5AI Score
0.002EPSS
Signal Handler Race Condition vulnerability in Mitsubishi Electric India GC-ENET-COM whose first 2 digits of 11-digit serial number of unit are "16" allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in Ethernet communication by sending a large number of specially...
7.5CVSS
5.8AI Score
0.002EPSS
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules and MELSEC iQ-R Series CPU modules allows a remote unauthenticated attacker to cause a denial of service (DoS) condition or execute malicious code o...
10CVSS
8.2AI Score
0.009EPSS
Active Debug Code vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 Serial number 2310 **** and prior allows a remote unauthenticated attacker to bypass authentication and illegally log into the affected module by connecting to it via telnet which is hidden function an...
8.6CVSS
8.7AI Score
0.002EPSS
Weak Password Requirements vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password...
7.5CVSS
7.6AI Score
0.003EPSS
Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP...
7.5CVSS
7.6AI Score
0.003EPSS
Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP...
6.2CVSS
6.6AI Score
0.001EPSS
Unrestricted Upload of File with Dangerous Type vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to cause information disclosure, tampering,...
7.3CVSS
7.1AI Score
0.001EPSS
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series main modules allows a remote unauthenticated attacker to cancel the password/keyword setting and login to the affected products by sending specially crafted packets.
9.1CVSS
9.1AI Score
0.002EPSS
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in MITSUBSHI CNC Series allows a remote unauthenticated attacker to cause Denial of Service (DoS) condition and execute arbitrary code on the product by sending specially crafted packets. In addition, system reset ...
9.8CVSS
9.7AI Score
0.007EPSS
Predictable Exact Value from Previous Values vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT21 model versions 01.49.000 and prior and GOT SIMPLE Series GS21 model versions 01.49.000 and prior allows a remote unauthenticated attacker to hijack data connections (session hijacking) ...
9.1CVSS
9AI Score
0.002EPSS
Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the pr...
9.3CVSS
8.4AI Score
0.002EPSS
Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegiti...
9.1CVSS
9.2AI Score
0.001EPSS
Improper Restriction of Excessive Authentication Attempts vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F/iQ-R Series CPU modules Web server function allows a remote unauthenticated attacker to prevent legitimate users from logging into the Web server function for a certain period afte...
5.3CVSS
5.3AI Score
0.001EPSS
Insufficient Verification of Data Authenticity vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules and MELSEC iQ-F Series CPU modules allows a remote unauthenticated attacker to reset the memory of the products to factory default state and cause denial-of-service (DoS) con...
9.1CVSS
9.1AI Score
0.001EPSS
Improper privilege management in Jungo WinDriver before 12.1.0 allows local attackers to escalate privileges and execute arbitrary code.
7.8CVSS
7.3AI Score
0.0004EPSS
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error.
5.5CVSS
6.2AI Score
0.0004EPSS
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
5.5CVSS
6.3AI Score
0.0004EPSS
Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in inform...
7.8CVSS
7.7AI Score
0.001EPSS
Improper Input Validation vulnerability in simulation function of GX Works2 allows an attacker to cause a denial-of-service (DoS) condition on the function by sending specially crafted packets. However, the attacker would need to send the packets from within the same personal computer where the fun...
4.7CVSS
4.7AI Score
0.0004EPSS
Improper Input Validation vulnerability in simulation function of GX Works2 allows an attacker to cause a denial-of-service (DoS) condition on the function by sending specially crafted packets. However, the attacker would need to send the packets from within the same personal computer where the fun...
4.7CVSS
4.7AI Score
0.0004EPSS
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote a...
7.5CVSS
7.7AI Score
0.001EPSS
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all v...
7.5CVSS
7.7AI Score
0.001EPSS
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 ver...
9.8CVSS
9.6AI Score
0.002EPSS
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error.
5.5CVSS
6.2AI Score
0.0004EPSS
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
5.5CVSS
6.3AI Score
0.0004EPSS
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
5.5CVSS
6.3AI Score
0.0004EPSS