Lucene search
+L

4501 matches found

ICS
ICS
•added 2024/11/12 7:00 a.m.•40 views

Hitachi Energy TRO600

RISK EVALUATION Command injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the web UI can execute commands on the device with root privileges, far more extensive...

7.2CVSS6.3AI score0.01606EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/12 7:00 a.m.•19 views

Subnet Solutions PowerSYSTEM Center

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause an integer overflow on the affected device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize...

9.8CVSS7.3AI score0.01686EPSS
SaveExploits1References10
ICS
ICS
•added 2024/11/12 5:00 a.m.•29 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E (Update B)

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

6.5AI score
SaveExploits0References11
ICS
ICS
•added 2024/11/12 12:00 a.m.•43 views

Siemens Solid Edge

SUMMARY Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as PAR or PSM format, and by a DLL hijacking vulnerability. This could allow an attacker to crash the application or execute...

7.8CVSS8AI score0.00189EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•20 views

Siemens RUGGEDCOM CROSSBOW

SUMMARY RUGGEDCOM CROSSBOW Station Access Controller SAC contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code or to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station...

9.8AI score
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•40 views

Schneider Electric EcoStruxure IT Gateway

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

10CVSS8.4AI score0.00642EPSS
SaveExploits0References11
ICS
ICS
•added 2024/11/12 12:00 a.m.•84 views

Schneider Electric PowerLogic PM5300 Series

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

8.7CVSS7.3AI score0.00816EPSS
SaveExploits0References11
ICS
ICS
•added 2024/11/12 12:00 a.m.•43 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E & EcoStruxure (Update A)

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

7.7CVSS7.2AI score0.00518EPSS
SaveExploits0References11
ICS
ICS
•added 2024/11/12 12:00 a.m.•78 views

Siemens SIMATIC CP

SUMMARY SIMATIC CP 1543-1 devices contain an Incorrect Authorization vulnerability that could allow an unauthenticated attacker to gain access to the filesystem. Siemens has released a new version for SIMATIC CP 1543-1 V4.0 and recommends to update to the latest version. 2. GENERAL...

8.7CVSS7.5AI score0.00481EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•38 views

Siemens Spectrum Power 7

SUMMARY Spectrum Power 7 before V24Q3 contains several root-owned SUID binaries that could allow an authenticated local attacker to escalate privileges. Siemens has released a new version for Spectrum Power 7 and recommends to update to the latest version. 2. GENERAL RECOMMENDATIONS Operators of...

8.5CVSS7.5AI score0.00142EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•31 views

Siemens SIPORT

SUMMARY SIPORT before V3.4.0 contains a privilege escalation vulnerability which could allow a local attacker with an unprivileged account to override or modify the service executable and subsequently gain elevated privileges. Siemens has released a new version for SIPORT and recommends to...

8.5CVSS7.5AI score0.00142EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•25 views

Siemens SCALANCE M-800 Family

SUMMARY SCALANCE M-800 family before V8.2 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends to protect network...

9.6AI score
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•24 views

Siemens Engineering Platforms

SUMMARY Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to...

7.3CVSS8.1AI score0.00218EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•30 views

Siemens Mendix Runtime

SUMMARY The basic authentication mechanism of Mendix Runtime contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures. Siemens has released new versions for several affected products and recommends to update to the...

6.9CVSS6.5AI score0.00275EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•36 views

Siemens TeleControl Server

SUMMARY TeleControl Server Basic V3.1 contains a deserialization vulnerability that could allow an unauthenticated attacker to execute arbitrary code on the device. Siemens has released new versions for the affected products and recommends to update to the latest versions. 2. GENERAL...

10CVSS8.7AI score0.00996EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•48 views

Siemens SINEC INS

SUMMARY SINEC INS before V1.0 SP2 Update 3 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends to protect network access to...

9.5AI score
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•47 views

Siemens OZW672 and OZW772 Web Server

SUMMARY OZW672 and OZW772 Web Server versions before V5.2 contain a stored cross-site scripting XSS vulnerability that could allow an authenticated remote attacker to inject arbitrary JavaScript code that is later executed by another authenticated victim user with potential higher privileges...

8.2CVSS7.1AI score0.00318EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•49 views

Siemens SINEC NMS

SUMMARY SINEC NMS before V3.0 SP1 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends to protect network access to devices...

5.3CVSS6.5AI score0.03047EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/07 7:00 a.m.•46 views

Delta Electronics DIAScreen

RISK EVALUATION Successful exploitation of this these vulnerabilities could crash the device being accessed; a buffer overflow condition may allow remote code execution. 2. RECOMMENDED PRACTICES CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying...

8.4CVSS8AI score0.00301EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/07 7:00 a.m.•77 views

Bosch Rexroth IndraDrive

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service, rendering the device unresponsive by sending arbitrary UDP messages. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of...

7.5CVSS6.1AI score0.00491EPSS
SaveExploits0References10
ICS
ICS
•added 2024/11/07 7:00 a.m.•56 views

Beckhoff Automation TwinCAT Package Manager

RISK EVALUATION Successful exploitation this vulnerability could allow a local attacker with administrative access rights to execute arbitrary OS commands on the affected system. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this...

6.5CVSS6.9AI score0.00188EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/31 6:00 a.m.•23 views

Rockwell Automation FactoryTalk ThinManager

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to send crafted messages to the device resulting in database manipulation or a denial-of-service condition. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of...

7.2AI score
SaveExploits0References10
ICS
ICS
•added 2024/10/29 6:00 a.m.•59 views

Delta Electronics InfraSuite Device Master

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Delta Electronics Equipment : InfraSuite Device Master Vulnerability : Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an...

9.8CVSS8.5AI score0.17589EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/29 6:00 a.m.•45 views

Solar-Log Base 15

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.1 ATTENTION : Exploitable remotely/low attack complexity/public exploits are available Vendor : Solar-Log Equipment : Base 15 Vulnerability : Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' 2. RISK EVALUATION Successful...

5.4CVSS5.5AI score0.0045EPSS
SaveExploits4References10
ICS
ICS
•added 2024/10/29 12:00 a.m.•32 views

Hitachi Energy MSM (Update A)

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to impact the confidentiality, integrity or availability of the MSM. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA...

7AI score
SaveExploits0References9
ICS
ICS
•added 2024/10/24 6:00 a.m.•33 views

iniNet Solutions SpiderControl SCADA PC HMI Editor

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION : Exploitable remotely/low attack complexity Vendor : iniNet Solutions Equipment : SpiderControl SCADA PC HMI Editor Vulnerability : Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain...

8.6CVSS6AI score0.005EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/24 6:00 a.m.•46 views

VIMESA VHF/FM Transmitter Blue Plus

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION : Exploitable remotely/low attack complexity/public exploits are available Vendor : VIMESA Equipment : VHF/FM Transmitter Blue Plus Vulnerability : Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could...

6.9CVSS5.8AI score0.00393EPSS
SaveExploits1References10
ICS
ICS
•added 2024/10/24 6:00 a.m.•62 views

Deep Sea Electronics DSE855

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION : low attack complexity/public exploits are available Vendor : Deep Sea Electronics Equipment : DSE855 Vulnerability : Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an...

6.5CVSS6.3AI score0.02418EPSS
SaveExploits3References10
ICS
ICS
•added 2024/10/23 12:00 a.m.•58 views

Siemens InterMesh Subscriber Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

10CVSS7AI score0.01238EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/22 6:00 a.m.•67 views

Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric Products (Update C)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION : Low attack complexity Vendor : ICONICS, Mitsubishi Electric Equipment : ICONICS Product Suite, Mitsubishi Electric MC Works64 Vulnerability : Incorrect Default Permissions 2. RISK EVALUATION Successful exploitation of this vulnerability could...

7.8CVSS7.2AI score0.00192EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/17 6:00 a.m.•35 views

HMS Networks EWON FLEXY 202

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION : Exploitable remotely/low attack complexity Vendor : HMS Networks Equipment : EWON FLEXY 202 Vulnerability : Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to sniff...

8.2CVSS5.7AI score0.00299EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/17 6:00 a.m.•37 views

LCDS LAquis SCADA

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION : Exploitable remotely/low attack complexity Vendor : LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME Equipment : LAquis SCADA Vulnerability : Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability...

7CVSS6.7AI score0.00651EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/17 6:00 a.m.•62 views

Elvaco M-Bus Metering Gateway CMe3100 (Update A)

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION : Exploitable remotely/low attack complexity Vendor : Elvaco Equipment : M-Bus Metering Gateway CMe3100 Vulnerabilities : Missing Authentication for Critical Function, Unrestricted Upload of File with Dangerous Type, Improper Neutralization of...

9.2CVSS5.7AI score0.0052EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/17 6:00 a.m.•61 views

Kieback&Peter DDC4000 Series

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Kieback&Peter Equipment : DDC4000 Series Vulnerabilities : Path Traversal, Insufficiently Protected Credentials, Use of Weak Credentials 2. RISK EVALUATION Successful exploitation of these...

9.8CVSS5.8AI score0.00635EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/17 12:00 a.m.•42 views

Mitsubishi Electric CNC Series (Update D)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION : Exploitable remotely Vendor : Mitsubishi Electric Equipment : CNC Series Vulnerability : Improper Validation of Specified Quantity in Input 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote...

5.9CVSS5.9AI score0.00563EPSS
SaveExploits0References9
ICS
ICS
•added 2024/10/16 12:00 p.m.•77 views

Iranian Cyber Actors’ Brute Force and Credential Access Activity Compromises Critical Infrastructure Organizations

Summary The Federal Bureau of Investigation FBI, the Cybersecurity and Infrastructure Security Agency CISA, the National Security Agency NSA, the Communications Security Establishment Canada CSE, the Australian Federal Police AFP, and Australian Signals Directorate's Australian Cyber Security...

10CVSS8.2AI score0.99389EPSS
SaveExploits79References90
ICS
ICS
•added 2024/10/10 6:00 a.m.•45 views

Rockwell Automation ControlLogix

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : ControlLogix Vulnerability : Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to send a...

8.7CVSS7AI score0.00551EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/10 6:00 a.m.•103 views

Delta Electronics CNCSoft-G2

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION : low attack complexity Vendor : Delta Electronics Equipment : CNCSoft-G2 Vulnerabilities : Stack-based Buffer Overflow, Out-of-bounds Write, Heap-Based Buffer Overflow, Out-of-bounds Read, Use of Uninitialized Variable 2. RISK EVALUATION...

8.4CVSS7.2AI score0.0342EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/10 6:00 a.m.•33 views

Rockwell Automation PowerFlex 6000T

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.2 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : PowerFlex 6000T Vulnerability : Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could...

8.2CVSS7AI score0.00516EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/10 6:00 a.m.•83 views

Rockwell Automation Logix Controllers

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : Compact GuardLogix, CompactLogix, ControlLogix, GuardLogix, 1756-EN4TR Vulnerability : Uncontrolled Resource Consumption 2. RISK EVALUATION Successful...

8.7CVSS6.8AI score0.00521EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/10 6:00 a.m.•34 views

Rockwell Automation DataMosaix Private Cloud

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : DataMosaix Private Cloud Vulnerabilities : Inadequate Encryption Strength, Out-of-bounds Write, Improper Check for Dropped Privileges, Reliance on...

9.8CVSS6.7AI score0.10451EPSS
SaveExploits6References10
ICS
ICS
•added 2024/10/10 6:00 a.m.•40 views

Rockwell Automation Verve Asset Manager

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : Verve Asset Manager Vulnerability : Placement of User into Incorrect Group 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an...

8.4CVSS6.5AI score0.00408EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/10 6:00 a.m.•37 views

Rockwell Automation DataMosaix Private Cloud

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : DataMosaix Private Cloud Vulnerabilities : Exposure of Sensitive Information to an Unauthorized Actor, Missing Authorization, Incorrect Authorization 2. RISK...

8.7CVSS5.9AI score0.00543EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/10 6:00 a.m.•55 views

Schneider Electric Zelio Soft 2

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Schneider Electric Equipment : Zelio Soft 2 Vulnerabilities : Use After Free, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an...

7.8CVSS6.3AI score0.00209EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/10 12:00 a.m.•40 views

Siemens Siveillance Video Camera

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

7.3CVSS7AI score0.00232EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/08 12:00 p.m.•19 views

Microsoft Releases October 2024 Security Updates

Microsoft released security updates to address vulnerabilities in multiple products. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system. CISA encourages users and administrators to review the following and apply necessary updates: Microsoft...

7.6AI score
SaveExploits0References18
ICS
ICS
•added 2024/10/08 4:00 a.m.•35 views

Schneider Electric EcoStruxure Power Monitoring Expert (PME) (Update B)

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

7.3CVSS7.1AI score0.00342EPSS
SaveExploits0References11
ICS
ICS
•added 2024/10/08 12:00 a.m.•41 views

Schneider Electric Data Center Expert

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION : Exploitable remotely/low attack complexity Vendor : Schneider Electric Equipment : Data Center Expert Vulnerability : Improper Verification of Cryptographic Signature, Missing Authentication for Critical Function 2. RISK EVALUATION Successful...

7.2CVSS6.7AI score0.00548EPSS
SaveExploits0References11
ICS
ICS
•added 2024/10/08 12:00 a.m.•106 views

Siemens Tecnomatix Plant Simulation

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

7.8CVSS7.4AI score0.00263EPSS
SaveExploits0References10
ICS
ICS
•added 2024/10/08 12:00 a.m.•102 views

Siemens PSS SINCAL

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

8.8CVSS6.2AI score0.0022EPSS
SaveExploits0References10
Total number of security vulnerabilities4501