4473 matches found
Siemens SINEMA Server Privilege Escalation Vulnerability (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-215-02 Siemens SINEMA Server Privilege Escalation Vulnerability that was published August 2, 2016, on the NCCIC/ICS-CERT web site. --------- Begin Update A Part 1 of 2 -------- Security researcher rgod working...
Moxa SoftCMS SQL Injection Vulnerability
OVERVIEW Zhou Yu of Acorn Network Security has identified a SQL injection vulnerability in Moxa's SoftCMS. ZDI reported this vulnerability to ICS-CERT. Moxa has produced an update to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED PRODUCTS Moxa reports that t...
Fultek WinTr Directory Traversal
Overview Researcher Daiki Fukumori of Cyber Defense Institute has identified a directory traversal vulnerability in Fultek’s WinTr SCADA application. Fultek was unable to validate this vulnerability and has not offered any mitigation plans. ICS-CERT has validated the vulnerability. This...
RealFlex RealWinDemo DLL Hijack
Overview Independent researcher Carlos Mario Penagos Hollmann has identified an uncontrolled search path element vulnerability, commonly referred to as a DLL hijack, in the RealFlex RealWinDemo application. RealFlex Technologies has produced an upgrade to address this vulnerability, which Mr...
Unitronics UNIOPC Server Input Handling Vulnerability
Overview Independent security researchers Billy Rios and Terry McCorkle have identified a vulnerability in Unitronics’ UniOPC Server product. --------- Begin Update A Part 1 of 3 -------- This vulnerability is a result of improper handling of input by a third-party component, https50.ocx, which i...
igloohome Smart Lock Mobile Application
ADVISORY SUMMARY Successful exploitation of this vulnerability could allow an unauthorized actor to access functions or backend services. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure...
Siemens SIDIS Secured SmartPlug
SUMMARY SIDIS Secured SmartPlug before V7.26.0310 is affected by multiple vulnerabilities in the components OpenSSL, OpenSSH, and several other packages as described below. Siemens has released a new version of SIDIS Secured SmartPlug and recommends to update to the latest version. 2. GENERAL...
StoneFly Storage Concentrator
ADVISORY SUMMARY Successful exploitation of these vulnerabilities could allow attackers to gain broad unauthorized access, execute arbitrary commands with root privileges, steal sensitive data, and perform actions on behalf of legitimate users across interconnected systems. 2. RECOMMENDED...
Frangoteam FUXA SCADA/HMI
ADVISORY SUMMARY Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to enumerate all user accounts and role assignments on a FUXA SCADA/HMI instance. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of...
AVer PTC cameras
ADVISORY SUMMARY Successful exploitation of this vulnerability could allow arbitrary code execution. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or...
Technitium DNS Amplification
RISK EVALUATION Technitium DNS Server aggressively tries to fetch missing RRSIG records or mismatched DNSKEY records. An attacker in control of a domain can cause a vulnerable system to generate excessive network traffic. 2. RECOMMENDED PRACTICES Fixed in version 15.0. 3. DESCRIPTION Technitium...
Siemens SICAM 8 Products
SUMMARY Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - RTUM85 for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 -...
Siemens SIMATIC
SUMMARY SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and recommends to update to the...
YoSmart YoLink Smart Hub
RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to remotely control other users' smart home devices, intercept sensitive data, and hijack sessions. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation...
Siemens COMOS
SUMMARY COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released new versions for several affected products and recommends to update to...
International Standards Organization ISO 15118-2 (Update A)
RISK EVALUATION Successful exploitation of this vulnerability could result in man-in-the-middle attacks. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system...
AutomationDirect MB-Gateway
RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to make configuration changes, disrupt operations, or achieve arbitrary code execution. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this...
Hitachi Energy MACH PS700
SUMMARY Hitachi Energy is aware of a vulnerability in third party component Intel Chipset Device Software, that affects MACH PS700 v2 product versions listed in this document. Authenticated malicious clients successfully exploiting this vulnerability could escalate the privilege to cause...
CISA Adds One Known Exploited Vulnerability to Catalog
CISA has added one new vulnerability to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation. CVE-2024-8963 Ivanti Cloud Services Appliance CSA Path Traversal Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and...
Rockwell Automation Pavilion8
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : Pavilion8 Vulnerabilities : Improper Privilege Management, Path Traversal 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an...
Johnson Controls Inc. Software House C●CURE 9000 (Update B)
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION : Exploitable remotely/Low attack complexity Vendor : Johnson Controls Inc. Equipment : Software House C●CURE 9000 Vulnerability : Incorrect Default Permissions 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an...
Johnson Controls Illustra Essentials Gen 4 (Update A)
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Johnson Controls, Inc. Equipment : Illustra Essentials Gen 4 Vulnerability : Storing Passwords in a Recoverable Format 2. RISK EVALUATION Successful exploitation of this vulnerability may...
MicroDicom DICOM Viewer
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : MicroDicom Equipment : DICOM Viewer Vulnerabilities : Improper Authorization in Handler for Custom URL Scheme, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these...
Westermo EDW-100
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Westermo Equipment : EDW-100 Vulnerabilities : Use of Hard-coded Password, Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of these vulnerabilities could...
EFACEC BCU 500
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.6 ATTENTION : Exploitable remotely/low attack complexity Vendor : EFACEC Equipment : BCU 500 Vulnerabilities : Uncontrolled Resource Consumption, Cross-site Request Forgery 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an...
Schneider Electric Easy UPS Online Monitoring Software
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Vendor: Schneider Electric Equipment: Easy UPS Online Monitoring Software Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow elevation of privileges which could result in arbitrary file...
Zebra ZTC Industrial ZT400 and ZTC Desktop GK420d
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.4 ATTENTION : Exploitable with adjacent access/low attack complexity Vendor : Zebra Technologies Equipment : ZTC Industrial ZT410, ZTC Desktop GK420d Vulnerability : Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful...
Siemens RUGGEDCOM APE1808 Devices
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
CODESYS Development System
1. EXECUTIVE SUMMARY CVSS v3 3.3 ATTENTION: low attack complexity Vendor: CODESYS, GmbH Equipment: CODESYS Development System Vulnerability: Improper Restriction of Excessive Authentication Attempts. 2. RISK EVALUATION Successful exploitation of this vulnerability could provide a local attacker...
Siemens Parasolid Installer
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services ...
Siemens SIMATIC WinCC V7
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens Solid Edge
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens Mendix Workflow Commons
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens APOGEE, TALON and Desigo PXC/PXM Products
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: FTP Server of Nucleus RTOS based APOGEE, TALON and Desigo PXC/PXM Products Vulnerabilities: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of these...
Measuresoft ScadaPro Server
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Measuresoft Equipment: ScadaPro Server Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local user with limited privileges to modify the service binary...
North Korean State-Sponsored Cyber Actors Use Maui Ransomware to Target the Healthcare and Public Health Sector
Summary The Federal Bureau of Investigation FBI, Cybersecurity and Infrastructure Security Agency CISA, and the Department of the Treasury Treasury are releasing this joint Cybersecurity Advisory CSA to provide information on Maui ransomware, which has been used by North Korean state-sponsored...
Hitachi Energy Relion 670 650 series and SAM600-IO Product
SUMMARY Hitachi Energy is aware of two critical memory allocation vulnerabilities called BadAlloc 1 vulnerabilities in the WindRiver VxWorks Operating Systems 23 that are used in our product versions listed in this advisory. An attacker that exploits these vulnerabilities might bypass security...
Siemens POWER METER SICAM Q100
1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: POWER METER SICAM Q100 Vulnerability: Stack-based Buffer Overflow\ 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to remotely execute code...
Delta Electronics TPEditor
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: TPEditor Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability may allow for arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED...
Defending Against Malicious Cyber Activity Originating from Tor
Summary This advisory uses the MITRE Adversarial Tactics, Techniques, and Common Knowledge ATT &CK® and Pre-ATT&CK framework. See the ATT&CK for Enterprise and Pre-ATT&CK frameworks for referenced threat actor techniques. This advisory—written by the Cybersecurity Security and Infrastructure...
Siemens Mendix SAML Module
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Mendix SAML Module Vulnerability: Insufficient Verification of Data Authenticity 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate...
Panasonic FPWIN Pro
1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Low skill level to exploit Vendor: Panasonic Equipment: FPWIN Pro Vulnerability: Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an out-of-bounds read, which may allow remote code execution. 3...
i-SENS, Inc. SmartLog Diabetes Management Software
OVERVIEW Independent researcher Mark Cross has identified an uncontrolled search path element vulnerability in i-SENS, Inc. SmartLog Diabetes Management Software. i-SENS has produced an update that mitigates this vulnerability. Mark Cross has tested the update to validate that it resolves the...
Everest Software PeakHMI Pointer Dereference Vulnerabilities
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on August 20, 2015, and is being released to the NCCIC/ICS-CERT web site. Independent researcher Josep Pi Rodriguez has identified two-pointer dereference vulnerabilities in the Everest Software LLC PeakHMI...
Catapult Software DNP3 Driver Improper Input Validation
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 24, 2013, and is now being released to the NCCIC/ICS-CERT Web site. Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation in Catapult Software’s DN...
IOServer OPC Server Multiple Vulnerabilities
Overview Independent researcher Hinge of foofus.net has identified multiple vulnerabilitiesIOServer “Root Directory” Trailing Backslash Web Server Vuln, http://www.foofus.net/?pageid=616, Web site last accessed September 13, 2012. in IOServer’s OPC Server application. IOServer has released a new...
7-Technologies IGSS ODBC Remote Stack Overflow
Overview Security researcher James Burton of Insomnia Security has released details of a remote stack overflow vulnerability affecting 7-Technologies 7T Interactive Graphical SCADA System IGSS. This vulnerability exists in the IGSS Open Database Connectivity ODBC service running on Port 22202/TCP...
Advantech Studio Test Web Server Buffer Overflow
Overview The ICS-CERT has received a report from independent security researcher Jeremy Brown that reveals a stack-based buffer overflow vulnerability in the test web server bundled with Advantech Studio Version 6.1. This web server is intended to be used for testing purposes and should not be us...
Savannah lwIP SMTP client
ADVISORY SUMMARY Successful exploitation of this vulnerability could crash the device being accessed; a buffer overflow condition may allow remote code execution. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability...
Haiwell IoT Cloud HMI Gateway
ADVISORY SUMMARY Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize...