Lucene search
+L
IcsMost viewed

4426 matches found

ICS
ICS
•added 2022/01/06 12:00 a.m.•44 views

Omron CX-One

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Omron Equipment: CX-One Vulnerabilities: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability may allow arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The...

7.8CVSS8.3AI score0.09271EPSS
SaveExploits0References5
ICS
ICS
•added 2021/12/14 12:00 a.m.•44 views

Siemens Teamcenter Active Workspace

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Teamcenter Active Workspace Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to achieve remove code execution...

7.2CVSS7.3AI score0.01052EPSS
SaveExploits0References11
ICS
ICS
•added 2021/11/09 12:00 a.m.•44 views

Siemens NX JT Translator

1. EXECUTIVE SUMMARY CVSS v3 3.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: NX Vulnerabilities: Out-of-bounds Read, Access of Uninitialized Pointer 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead to access violation and arbitrary code execution on...

4.3CVSS5.4AI score0.00966EPSS
SaveExploits0References11
ICS
ICS
•added 2021/11/04 12:00 a.m.•44 views

Philips Tasy EMR

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Philips Equipment: Tasy EMR Vulnerabilities: SQL Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in patient’s confidential data...

8.8CVSS9.3AI score0.0125EPSS
SaveExploits2References5
ICS
ICS
•added 2021/06/22 12:00 a.m.•44 views

CODESYS V2 web server

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: CODESYS, GmbH Equipment: CODESYS V2 web server Vulnerabilities: Stack-based Buffer Overflow, Improper Access Control, Buffer Copy without Checking Size of Input, Improperly Implemented Security Check,...

9.8CVSS10AI score0.01391EPSS
SaveExploits0References4
ICS
ICS
•added 2021/06/08 12:00 a.m.•44 views

Siemens JT2Go and Teamcenter Visualization

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: JT2Go and Teamcenter Visualization Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current...

7.8CVSS7.8AI score0.0191EPSS
SaveExploits0References11
ICS
ICS
•added 2021/02/12 12:00 p.m.•44 views

Compromise of U.S. Water Treatment Facility

Summary On February 5, 2021, unidentified cyber actors obtained unauthorized access to the supervisory control and data acquisition SCADA system at a U.S. drinking water treatment facility. The unidentified actors used the SCADA system’s software to increase the amount of sodium hydroxide, also...

9.9AI score
SaveExploits0References18
ICS
ICS
•added 2020/10/13 12:00 a.m.•44 views

LCDS LAquis SCADA

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: LCDS—Leão Consultoria e Desenvolvimento de Sistemas Ltda ME Equipment: LAquis SCADA Vulnerability: Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute...

7.8CVSS7.7AI score0.01939EPSS
SaveExploits0References5
ICS
ICS
•added 2019/06/27 12:00 a.m.•44 views

Advantech WebAccess/SCADA

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Advantech Equipment: WebAccess/SCADA Vulnerabilities: Path Traversal, Stack-based Buffer Overflow, Heap-based Buffer Overflow, Out-of-bounds Read, Out-of-bounds Write, Untrusted Pointer Dereference...

9.8CVSS10AI score0.10665EPSS
SaveExploits0References5
ICS
ICS
•added 2018/12/13 12:00 a.m.•44 views

Schneider Electric GUIcon Eurotherm

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION : Low skill level to exploit Vendor : Schneider Electric Equipment : Eurotherm by Schneider Electric GUIcon Vulnerabilities : Type Confusion, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow an...

7.8CVSS8.5AI score0.01233EPSS
SaveExploits0References5
ICS
ICS
•added 2018/09/10 12:00 p.m.•44 views

Siemens SIMATIC HMI Devices Vulnerabilities

OVERVIEW Siemens has identified three vulnerabilities in its SIMATIC HMI devices. These vulnerabilities were reported directly to Siemens by the Quarkslab team and Ilya Karpov from Positive Technologies. Siemens has produced updates that mitigate these vulnerabilities in most of the affected...

6.8CVSS5.6AI score0.02134EPSS
SaveExploits0References27
ICS
ICS
•added 2017/08/17 12:00 a.m.•44 views

ICSMA-17-229-01_Philips' DoseWise Portal Vulnerabilities

OVERVIEW Philips has identified Hard-coded Credentials and Cleartext Storage of Sensitive Information vulnerabilities in Philips’ DoseWise Portal DWP web application. Philips has updated product documentation and produced a new version that mitigates these vulnerabilities. These vulnerabilities...

9.1CVSS9.7AI score0.02225EPSS
SaveExploits0References2
ICS
ICS
•added 2017/08/10 12:00 a.m.•44 views

Solar Controls WATTConfig M Software

CVSS v3 7.8 ATTENTION: Low skill level to exploit. Vendor: Solar Controls Equipment: WATTConfig M Software Vulnerability: Uncontrolled Search Path Element AFFECTED PRODUCTS The following versions of Solar Controls’ WATTConfig M Software for Windows 2.5.10 for M SSR/MAX PLCs are affected: WATTConf...

9.3CVSS8AI score0.01761EPSS
SaveExploits0References3
ICS
ICS
•added 2017/07/13 12:00 a.m.•44 views

GE Communicator

CVSS v3 7.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: GE Equipment: Communicator Vulnerability: Heap-Based Buffer Overflow AFFECTED PRODUCTS The following versions of Communicator, an application for programming and monitoring supported metering devices, are affected:...

7.6CVSS1AI score0.0099EPSS
SaveExploits0References27
ICS
ICS
•added 2017/06/27 12:00 a.m.•44 views

Newport XPS-Cx, XPS-Qx

CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Newport Equipment: XPS-Cx, XPS-Qx Vulnerability: Improper Authentication AFFECTED PRODUCTS The following versions of XPS-Cx and XPS-Qx, a universal motion controller, are affected: XPS-Cx all versions, and XPS-Qx all...

9.8CVSS9.8AI score0.02602EPSS
SaveExploits0References3
ICS
ICS
•added 2017/06/22 12:00 a.m.•44 views

Siemens SIMATIC CP 44x-1 Redundant Network Access Modules

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIMATIC CP 44x-1 Redundant Network Access RNA modules Vulnerability: Improper Authentication AFFECTED PRODUCTS The following versions of the SIMATIC CP 44x-1 RNA, which connect SIMATIC S7-400 CPUs t...

8.1CVSS8.8AI score0.04174EPSS
SaveExploits0References3
ICS
ICS
•added 2017/03/23 12:00 a.m.•44 views

ICSMA-17-082-01_BD Kiestra PerformA and KLA Journal Service Applications Hard-Coded Passwords Vulnerability

OVERVIEW Becton, Dickinson and Company BD has identified a hard-coded password vulnerability in BD’s Kiestra PerformA and KLA Journal Service applications that access the BD Kiestra Database. BD has produced compensating controls to reduce the risk of exploitation of the identified vulnerability ...

9.8CVSS9.8AI score0.01752EPSS
SaveExploits0References2
ICS
ICS
•added 2015/09/05 6:00 a.m.•44 views

Hospira Multiple Products Buffer Overflow Vulnerability

OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on December 3, 2015, and is being released to the NCCIC/ICS-CERT web site. Jeremy Richards of SAINT Corporation has identified a buffer overflow vulnerability in Hospira’s LifeCare PCA Infusion System. Hospira has...

7.5CVSS7.9AI score0.01112EPSS
SaveExploits0References10
ICS
ICS
•added 2015/08/13 12:00 p.m.•44 views

OSIsoft PI Data Archive Server Vulnerabilities

OVERVIEW OSIsoft has identified 56 vulnerabilities in its own PI System software. OSIsoft has produced a new version of Data Archive Version 3.4.395.64 to mitigate these issues. Some of these vulnerabilities could be exploited remotely. AFFECTED PRODUCTS OSIsoft reports that the vulnerabilities...

8.1AI score
SaveExploits0References17
ICS
ICS
•added 2015/07/30 6:00 a.m.•44 views

Siemens RuggedCom Improper Ethernet Frame Padding Vulnerability

OVERVIEW David Formby and Raheem Beyah of Georgia Tech have identified a vulnerability caused by an Institute of Electrical and Electronics Engineers IEEE conformance issue involving improper frame padding in Siemens RuggedCom ROS-based devices. Siemens has already released a revision that...

3.3CVSS6.4AI score0.00927EPSS
SaveExploits0References10
ICS
ICS
•added 2015/04/16 6:00 a.m.•44 views

Siemens SICAM MIC Authentication Bypass Vulnerability

OVERVIEW Siemens has identified an authentication bypass vulnerability in its SICAM MIC telecontrol device. This vulnerability was reported directly to Siemens by Philippe Oechslin from Objectif Sécurité. Siemens has produced a new firmware update to mitigate this vulnerability. This vulnerabilit...

9.3CVSS6.8AI score0.03271EPSS
SaveExploits0References10
ICS
ICS
•added 2014/10/17 6:00 a.m.•44 views

Schneider Electric ClearSCADA Uncontrolled Resource Consumption Vulnerability

OVERVIEW Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an uncontrolled resource consumption vulnerability in the Schneider Electric SCADA Expert ClearSCADA software. Schneider Electric has produced a new version that mitigates this vulnerability. Adam Crain has...

4.3CVSS7.2AI score0.01164EPSS
SaveExploits0References10
ICS
ICS
•added 2014/10/13 6:00 a.m.•44 views

MatrikonOPC Improper Input Validation

OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on January 10, 2014, and is now being released to the NCCIC/ICS-CERT web site. Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation vulnerability in the...

7.1CVSS6.2AI score0.01255EPSS
SaveExploits0References10
ICS
ICS
•added 2014/10/11 6:00 a.m.•44 views

Ecava Sdn Bhd IntegraXor Project Directory Information Disclosure Vulnerability

OVERVIEW NCCIC/ICS-CERT received a report from the Zero Day InitiativeEcava IntegraXor Project Directory Information Disclosure Vulnerability, http://www.zerodayinitiative.com/advisories/ZDI-13-277/, Web site last accessed January 08, 2014. ZDI regarding a project directory information disclosure...

7.5CVSS5.9AI score0.01795EPSS
SaveExploits0References10
ICS
ICS
•added 2014/08/23 6:00 a.m.•44 views

Advantech WebAccess Stack-based Buffer Overflow

OVERVIEW Ricardo Narvaja from Core Security Consulting Services discovered and disclosed information regarding a buffer overflow vulnerabilityCore Security Advantech WebAccess Stack-based Buffer Overflow, http://www.coresecurity.com/advisories/advantech-webaccess-stack-based-buffer-overflow web...

7.2CVSS7.3AI score0.01051EPSS
SaveExploits1References10
ICS
ICS
•added 2013/12/20 7:00 a.m.•44 views

Schneider Electric PLCs Vulnerabilities

OVERVIEW --------- Begin Update B Part 1 of 2 -------- This updated advisory is a follow-up to the previous advisory update titled ICSA-13-077-01A Schneider Electric PLCs Vulnerabilities Update A that was published March 20, 2013, on the ICS-CERT Web page. It is also a follow-up to the updated...

7.4AI score
SaveExploits0References10
ICS
ICS
•added 2013/09/06 6:00 a.m.•44 views

Siemens SINAMICS S/G Authentication Bypass Vulnerability

OVERVIEW Siemens has identified an authentication bypass vulnerability in the SINAMICS S/G product family. Siemens has produced a firmware update that mitigates this vulnerability and has tested the update to validate that it resolves the vulnerability. Exploitation of this vulnerability could...

10CVSS6.7AI score0.03235EPSS
SaveExploits0References10
ICS
ICS
•added 2012/06/03 6:00 a.m.•44 views

GarrettCom - Use of Hard-Coded Password

Overview Independent security researcher Justin W. Clarke of Cylance Inc. has identified a privilege-escalation vulnerability in the GarrettCom Magnum MNS-6K Management Software application via the use of a hard-coded password. This vulnerability could allow a remote attacker with any level of...

7.7CVSS7.3AI score0.00433EPSS
SaveExploits0References10
ICS
ICS
•added 2012/01/13 7:00 a.m.•44 views

MICROSYS PROMOTIC Use After Free Vulnerability

Overview This advisory is a follow-up to ICS-ALERT-11-333-01 - MICROSYS PROMOTIC Use-After-Free Vulnerability, released on the ICS-CERT Web site on November 28, 2011. Independent researcher Luigi Auriemma has identified and released proof of concept code POC for a use after free vulnerability in...

7.9CVSS7.4AI score0.0151EPSS
SaveExploits0References10
ICS
ICS
•added 2026/09/08 6:00 a.m.•43 views

CareCam Pro IP Cameras

ADVISORY SUMMARY Successful exploitation of this vulnerability could allow an attacker to take full control of the device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control...

7CVSS5.9AI score0.00294EPSS
SaveExploits0References13
ICS
ICS
•added 2026/08/27 6:00 a.m.•43 views

Ebyte NA111-M

ADVISORY SUMMARY Successful exploitation of these vulnerabilities could allow an attacker to fully compromise the device. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all...

5.9AI score
SaveExploits0References13
ICS
ICS
•added 2026/08/13 6:00 a.m.•43 views

Johnson Controls Inc. Airwall

ADVISORY SUMMARY Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. 2. RECOMMENDED...

5.9AI score
SaveExploits0References13
ICS
ICS
•added 2025/04/30 12:00 a.m.•43 views

ABB Automation Builder (Update A)

RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to overrule the Automation Builder's user management. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize...

8.5CVSS5.8AI score0.00151EPSS
SaveExploits0References10
ICS
ICS
•added 2025/02/11 12:00 a.m.•43 views

Siemens SIMATIC S7-1200 CPU Family

SUMMARY SIMATIC S7-1200 CPU family before V4.7 is affected by two denial of service vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends...

7.4AI score
SaveExploits0References10
ICS
ICS
•added 2024/11/12 12:00 a.m.•43 views

Siemens SINEC INS

SUMMARY SINEC INS before V1.0 SP2 Update 3 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends to protect network access to...

9.5AI score
SaveExploits0References10
ICS
ICS
•added 2024/09/24 6:00 a.m.•43 views

Franklin Fueling Systems TS-550 EVO

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : Franklin Fueling Systems Equipment : TS-550 EVO Automatic Tank Gauge Vulnerability : Absolute Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability allow an...

8.7CVSS8.1AI score0.00581EPSS
SaveExploits0References10
ICS
ICS
•added 2024/08/13 6:00 a.m.•43 views

Rockwell Automation FactoryTalk View Site Edition (Update A)

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION : Low attack complexity Vendor : Rockwell Automation Equipment : FactoryTalk View Site Edition Vulnerability : Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow...

8.8CVSS7AI score0.01656EPSS
SaveExploits0References10
ICS
ICS
•added 2024/06/06 6:00 a.m.•43 views

Mitsubishi Electric CC-Link IE TSN Industrial Managed Switch

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.1 ATTENTION : Exploitable remotely/low attack complexity Vendor : Mitsubishi Electric Equipment : CC-Link IE TSN Industrial Managed Switch Vulnerability : Allocation of Resources Without Limits or Throttling 2. RISK EVALUATION Successful exploitation of...

6.5CVSS7.6AI score0.75116EPSS
SaveExploits0References10
ICS
ICS
•added 2024/05/14 12:00 a.m.•43 views

Siemens Simcenter Nastran

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

7.8CVSS7.9AI score0.00231EPSS
SaveExploits0References12
ICS
ICS
•added 2024/05/07 6:00 a.m.•43 views

SUBNET Substation Server

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION : Low attack complexity Vendor : Subnet Solutions Inc. Equipment : Substation Server Vulnerabilities : Reliance on Insufficiently Trustworthy Component 2. RISK EVALUATION Successful exploitation of the vulnerabilities in components used by...

8.6CVSS8.9AI score0.00209EPSS
SaveExploits0References10
ICS
ICS
•added 2024/02/13 12:00 a.m.•43 views

Siemens SIMATIC RTLS Gateways

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

10CVSS9.7AI score0.36852EPSS
SaveExploits3References12
ICS
ICS
•added 2024/01/23 7:00 a.m.•43 views

Crestron AM-300

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.4 ATTENTION : Low attack complexity Vendor : Crestron Equipment : AM-300 Vulnerability : OS Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate their privileges to root-level access. 3...

8.4CVSS8.5AI score0.00529EPSS
SaveExploits0References8
ICS
ICS
•added 2023/12/12 7:00 a.m.•43 views

Schneider Electric Easy UPS Online Monitoring Software

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION : Vendor : Schneider Electric Equipment : Easy UPS Online Monitoring Software Vulnerability : Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow elevation of privileges which could result in arbitrary...

7.1CVSS6.7AI score0.00236EPSS
SaveExploits0References10
ICS
ICS
•added 2023/11/30 7:00 a.m.•43 views

Yokogawa STARDOM

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Yokogawa Equipment : STARDOM FCN/FCJ Vulnerability : Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to cause...

5.3CVSS5.5AI score0.01166EPSS
SaveExploits0References8
ICS
ICS
•added 2023/10/12 6:00 a.m.•43 views

Mitsubishi Electric MELSEC-F Series

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION : Exploitable remotely/low attack complexity Vendor : Mitsubishi Electric Corporation Equipment : MELSEC-F Series Vulnerability : Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability may allow a remote...

9.1CVSS9.4AI score0.0085EPSS
SaveExploits0References8
ICS
ICS
•added 2023/04/20 3:30 p.m.•43 views

INEA ME RTU

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: INEA Equipment: ME RTU Vulnerability: OS Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED...

10CVSS10AI score0.01663EPSS
SaveExploits0References5
ICS
ICS
•added 2023/04/11 12:00 a.m.•43 views

Siemens Adaptec Maxview Application

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

6.3CVSS6.4AI score0.00092EPSS
SaveExploits0References12
ICS
ICS
•added 2023/04/11 12:00 a.m.•43 views

Siemens Polarion ALM

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

7.5CVSS6.1AI score0.0059EPSS
SaveExploits0References12
ICS
ICS
•added 2023/03/02 7:00 a.m.•43 views

Mitsubishi Electric MELSEC iQ-F Series

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric --------- Begin Update A Part 1 of 4 --------- Equipment: MELSEC iQ-F, iQ-R, Q, and L series --------- Begin Update A Part 1 of 4 --------- Vulnerability: Plaintext Storage of...

7.5CVSS7.6AI score0.01174EPSS
SaveExploits0References10
ICS
ICS
•added 2023/02/14 12:00 a.m.•43 views

Siemens Mendix

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

7.5CVSS6.9AI score0.00498EPSS
SaveExploits0References11
Total number of security vulnerabilities4426