4347 matches found
PHOENIX CONTACT FL SWITCH
CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: PHOENIX CONTACT Equipment: FL SWITCH Vulnerabilities: Improper Authorization, Information Exposure AFFECTED PRODUCTS All FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0 to 1.32 are affecte...
Siemens Industrial products using the Discovery Service of the OPC UA protocol stack by the OPC foundation
CVSS v3 8.2 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: Industrial products using the Discovery Service of the OPC UA protocol stack by the OPC foundation Vulnerability: Improper Restriction of XML External Entity Reference UPDATE INFORMATION This update...
Siemens Reyrolle
CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: Reyrolle Vulnerabilities: Missing Authorization, Improper Input Validation, Improper Authentication AFFECTED PRODUCTS Siemens reports that the vulnerabilities affect the following Reyrolle...
Hyundai Motor America Blue Link
CVSS v3 7.5 ATTENTION: Remotely exploitable Vendor: Hyundai Motor America Equipment: Blue Link Vulnerability: Man-in-the-Middle, Use of Hard-Coded Cryptographic Key AFFECTED PRODUCTS The following versions of Blue Link, a mobile application for Hyundai vehicle management, are affected: Blue Link...
Belden Hirschmann GECKO
CVSS v3 5.9 ATTENTION: Remotely Exploitable/high skill level to exploit. Vendor: Belden Equipment: Hirschmann GECKO Vulnerability: Authentication Bypass Using an Alternate Path or Channel AFFECTED PRODUCTS The following GECKO switch versions are affected: Hirschmann GECKO Lite Managed switch,...
Siemens SICAM PAS Vulnerabilities
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-336-01 Siemens SICAM PAS Vulnerabilities that was published December 1, 2016, on the NCCIC/ICS-CERT web site. Siemens has released an advisory to inform its users on how to mitigate vulnerabilities that affect...
Schneider Electric PowerLogic PM8ECC Hard-coded Password Vulnerability
OVERVIEW Independent researcher He Congwen has identified a hard-coded password vulnerability in Schneider Electric’s PowerLogic PM8ECC device. Schneider Electric has produced a patch to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED PRODUCTS The following...
Eaton ELCSoft Programming Software Memory Vulnerabilities
OVERVIEW Ariele Calgaviano working with Zero Day Initiative has identified a heap-based memory corruption vulnerability and a stack buffer overflow vulnerability in Eaton’s ELCSoft programming software. Eaton has released a revision to mitigate these vulnerabilities. These vulnerabilities could b...
Hospira LifeCare PCA Infusion System Vulnerabilities
OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-15-125-01A Hospira LifeCare PCA Infusion System Vulnerabilities that was published May 13, 2015, on the NCCIC/ICS-CERT web site. --------- Begin Update B Part 1 of 9 -------- Independent researcher Billy Rios has...
Elipse SCADA DNP3 Denial of Service
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 30, 2014, and is being released to the NCCIC/ICS-CERT web site Independent researchers Adam Crain and Chris Sistrunk have identified a DNP3 denial‑of‑service vulnerability in the Elipse SCADA application...
IOServer Resource Exhaustion Vulnerability
OVERVIEW Chris Sistrunk of Mandiant and Adam Crain of Automatak have identified an out of bound read vulnerability in the IOServer application. IOServer has produced a new version that mitigates this vulnerability. Adam Crain has tested the new version to validate that it resolves the...
WellinTech KingView KingMess Buffer Overflow
Overview This updated advisory is a follow-up to the original advisory titled ICSA-13-043-02—WellinTech KingView KingMess Buffer Overflow that was published February 12, 2013, on the ICS-CERT Web page. This updated advisory provides mitigation details for a vulnerability that impacts the WellinTe...
Mitsubishi Electric Automation MX Component V3 ActiveX Vulnerability
OVERVIEW This advisory is a follow-up to the alert titled ICS-ALERT-13-091-01 Mitsubishi Electric Automation MX Buffer Overflow Vulnerability that was published April 1, 2013, on the ICS-CERT Web siteICSA-13-091-01, http://ics-cert.us-cert.gov/alerts/ICSA-13-091-01, last accessed May 20, 2013...
Wonderware SuiteLink Unallocated Unicode String Vulnerability
Overview This Advisory is a follow-up to the original ICS-CERT Alert titled ICS-ALERT-12-136-01 Wonderware SuiteLink Unallocated Unicode String that was published May 15, 2012 on the ICS-CERT web page. Independent researcher Luigi Auriemma identified a maliciously crafted Unicode string...
Safenet Sentinel and 7-T Input Sanitization Vulnerability
Overview ICS-CERT originally released advisory ICSA-11-314-01P on the US-CERT secure portal on November 14, 2011. This web page release was delayed to allow users time to download and install the update. Security researcher Carlos Mario Penagos Hollman of Synapse-labs has identified an input...
ABB Ability Zenon
SUMMARY ABB is aware of publicly reported vulnerabilities affecting MongoDB 4.2, which is bundled within the IIoT Services of the affected product versions. MongoDB 4.2 has reached end-of-life and contains multiple known security vulnerabilities. An attacker who successfully exploits these...
Siemens Simcenter Femap
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
#StopRansomware: Black Basta
Actions for critical infrastructure organizations to take today to mitigate cyber threats from ransomware: 1. Install updates for operating systems, software, and firmware as soon as they are released. 2. Require phishing-resistant MFA for as many services as possible. 3. Train users to recognize...
Hitachi Energy MACH SCM (Update A)
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.9 ATTENTION : Exploitable remotely Vendor : Hitachi Energy Equipment : MACH SCM Vulnerabilities : Improper Control of Generation of Code, Improper Neutralization of Directives in Dynamically Evaluated Code 2. RISK EVALUATION Successful exploitation of...
Rockwell Automation FactoryTalk Activation
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : FactoryTalk Activation Manager Vulnerabilities : Out-of-Bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in a...
Siemens SIMATIC IPCs
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens SIMATIC S7-1500 TM MFP BIOS
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Medtronic NGP 600 Series Insulin Pumps
1. EXECUTIVE SUMMARY CVSS v3 4.8 ATTENTION: Exploitable from an adjacent network Vendor: Medtronic Equipment: MiniMed 600 Series Insulin Pumps Vulnerability: Protection Mechanism Failure 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized user to deliver...
Hitachi Energy MSM Product
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: MSM Product Vulnerability: Reliance on Uncontrolled Component 2. RISK EVALUATION Successful exploitation of this vulnerability could disrupt the functionality of the MSM web...
Siemens SICAM GridEdge
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SICAM GridEdge Essential ARM Vulnerabilities: Missing Authentication for Critical Function, Resource Leak 2. RISK EVALUATION Successful exploitation of these vulnerabilities could...
Mitsubishi Electric MELSEC iQ-F Series
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: MELSEC iQ-F Series Vulnerabilities: Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-22-139-01...
Siemens Simcenter Femap
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Simcenter Femap Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could cause code execution if the affected application is used to open a malicious .NEU...
LifePoint Informatics Patient Portal
1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: LifePoint Informatics Equipment: Patient Portal Vulnerability: Authentication Bypass Using Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could disclose...
Hitachi Energy LinkOne WebView
1. EXECUTIVE SUMMARY CVSS v3 4.2 ATTENTION: Exploitable remotely Vendor: Hitachi Energy Equipment: LinkOne WebView Vulnerabilities: Cross-site Scripting, Use of a Password System for Primary Authentication, Configuration, Exposure of Sensitive Information to an Unauthorized Actor 2. RISK...
Siemens SICAM A8000
1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SICAM A8000 Vulnerabilities: Use of Hard-coded Credentials, Improper Access Control 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow a privileged user...
Hitachi ABB Power Grids System Data Manager
1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Low attack complexity Vendor: Hitachi ABB Power Grids Equipment: System Data Manager Vulnerability: Cleartext Storage of Sensitive Information 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker access to sensitive...
Advantech WebAccess/SCADA (Update A)
1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Advantech Equipment: WebAccess/SCADA Vulnerabilities: Open Redirect, Relative Path Traversal 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-168-03...
GENIVI Alliance DLT
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: GENIVI Alliance Equipment: DLT-Daemon Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to remote code execution or crash the...
Siemens and PKE SiNVR, SiVMS Video Server (Update A)
1. EXECUTIVE SUMMARY --------- Begin Update A Part 1 of 6 --------- CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendors: Siemens and PKE Equipment: SiNVR, SiVMS Video Servers Vulnerabilities: Missing Authentication for Critical Function, Weak Cryptography for Passwords...
Emerson DeltaV Distributed Control System
1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION: Low skill level to exploit Vendor: Emerson Equipment: DeltaV Distributed Control System DCS Vulnerability: Use of Hard-coded Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain administrative...
Lantech IDS 2102
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low skill level to exploit. Vendor : Lantech Equipment : IDS 2102 Vulnerabilities : Improper Input Validation, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker...
Siemens Ruggedcom ROS, SCALANCE (Update A)
CVSS v3 8.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: Ruggedcom ROS, SCALANCE Vulnerability: Improper Access Control UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-17-271-01 Siemens Ruggedcom ROS and SCALAN...
ICSA-17-138-01_Miele Professional PG 85 Series
CVSS v3 7.3 ATTENTION: Remotely exploitable/low skill level to exploit. Public exploits are available. Vendor: Miele Professional Equipment: PG 85 Series Vulnerability: Path Traversal UPDATED INFORMATION This advisory is a follow-up to the original alert titled ICS-ALERT-17-089-01 Miele...
Moxa ioLogik E2200 Series Weak Authentication Practices
OVERVIEW This advisory is a follow-up to the alert titled ICS-ALERT-15-224-04 Moxa ioLogik E2210 VulnerabilitiesICS-ALERT-15-224-04 Moxa ioLogik E2210 Vulnerabilities, https://ics-cert.us-cert.gov/alerts/ICS-ALERT-15-224-04, web site last accessed March 03, 2016. that was published August 12, 201...
Moxa EDR-G903 Secure Router Vulnerabilities (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-042-01 Moxa EDR‑G903 Secure Router Vulnerabilities that was published May 17, 2016, on the NCCIC/ICS-CERT web site. Independent researcher Maxim Rupp has identified vulnerabilities in Moxa’s EDR‑G903 secure...
Siemens SIMATIC WinCC and SIMATIC PCS 7 ActiveX Vulnerability
OVERVIEW Mingzheng Li from Acorn Network Security Lab has identified an ActiveX vulnerability in Siemens’ SIMATIC WinCC and SIMATIC PCS 7. Siemens has produced a new version to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED PRODUCTS Siemens reports that the...
Meteocontrol WEB'log Vulnerabilities (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-133-01 Meteocontrol WEB'log Vulnerabilities that was published May 12, 2016, on the NCCIC/ICS‑CERT web site. Independent researcher Karn Ganeshen has identified one authentication and two information exposure...
Hospira Symbiq Infusion System Vulnerability
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on June 23, 2015, and is being released to the NCCIC/ICS-CERT web site. Independent researcher Billy Rios identified a vulnerability in Hospira’s Symbiq Infusion System, which can be exploited to remotely control th...
OSIsoft PI Interface for DNP3 Improper Input Validation
OVERVIEW Adam Crain of Automatak and Chris Sistrunk, Sr. Consultant for Mandiant, have identified an improper input validation vulnerability in the OSIsoft PI Interface for DNP3 product. OSIsoft has produced an update that mitigates this vulnerability. OSIsoft and Automatak have tested the new...
Siemens WinCC TIA Portal Vulnerabilities
Overview This advisory provides mitigation details for a vulnerability that impacts the Siemens WinCC TIA Totally Integrated Automation Portal HMI. Researchers Billy Rios and Terry McCorkle of Cylance; Gleb Gritsai, Sergey Bobrov, Roman Ilin, Artem Chaykin, Timur Yunusov, and Ilya Karpov from...
WellinTech Vulnerabilities
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on December 10, 2013, and is now being released to the NCCIC/ICS-CERT Web site. NCCIC/ICS-CERT received reports from the Zero Day Initiative ZDI regarding a remote code execution vulnerability and an information...
Siemens Questa and ModelSim
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
National Instruments LabVIEW
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION : Low attack complexity Vendor : National Instruments Equipment : LabVIEW Vulnerabilities : Out-of-Bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of these...
Siemens RUGGEDCOM
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens Desigo Fire Safety UL and Cerberus PRO UL Fire Protection Systems