ABB FOX515T Improper Input Validation (CVE-2017-14025)

An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. An improper input validation vulnerability has been identified, allowing a local attacker to provide a malicious parameter to the script that is not validated by the application, This could enable the attacker to retrie...

5.5CVSS5.7AI score0.00391EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.28 views

Mitsubishi Electric MELSEC and MELIPC Denial Of Service (CVE-2020-5531)

Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller ModuleQ24DHCCPU-V, Q24DHCCPU-VG User Ethernet port CH1, CH2: First 5 digits of serial number 21121 or before, MELSEC iQ-R Series C Controller Module / C Intelligent Function ModuleR12CCPU-V Ethern...

9.8CVSS8.5AI score0.02025EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.25 views

Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2020-16850)

Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...

7.8CVSS7.2AI score0.02143EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.27 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Improper Neutralization of Special Elements Used in an OS Command (CVE-2019-14931)

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's...

10CVSS8.9AI score0.5809EPSS
SaveExploits3References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.26 views

Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Weak Password Requirements (CVE-2017-7903)

A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable- logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version...

9.8CVSS7.4AI score0.02759EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.30 views

Rockwell Automation Micrologix Improper Access Control (CVE-2017-14472)

An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...

10CVSS7.4AI score0.37965EPSS
SaveExploits1References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.40 views

Yokogawa CENTUM, Exaopc and B/M9000 Stack-based Buffer Overflow (CVE-2014-0782)

Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and earlier, B/M9000CS R5.05.01 and earlier,...

8.3CVSS6.4AI score0.56839EPSS
SaveExploits4References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.24 views

Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6846)

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause information disclosure when using the FTP protocol. This plugin only works with Tenable.ot. Please visit...

6.5CVSS6.5AI score0.00981EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.33 views

Siemens SIMATIC CP 343-1/CP 443-1 Modules and SIMATIC S7-300/S7-400 CPUs (CVE-2016-8672)

A vulnerability has been identified in SIMATIC CP 343-1 Advanced incl. SIPLUS NET variant All versions V3.0.53, SIMATIC CP 443-1 Advanced incl. SIPLUS NET variant All versions V3.2.17, SIMATIC S7-300 PN/DP CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP CPU family incl. SIPLUS...

5.3CVSS6.2AI score0.01852EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.18 views

Schneider Electric Modicon Quantum Improper Access Control (CVE-2019-6815)

In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol. This plugin only works with Tenable.ot. Please visit...

9.1CVSS8.3AI score0.01399EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.23 views

Siemens SIMATIC S7-400 CPU Improper Input Validation (CVE-2018-4850)

A vulnerability has been identified in SIMATIC S7-400 incl. F CPU hardware version 4.0 and below All versions, SIMATIC S7-400 incl. F CPU hardware version 5.0 All firmware versions V5.2, SIMATIC S7-400H CPU hardware version 4.5 and below All versions. The affected CPUs improperly validate S7...

7.5CVSS7.2AI score0.02512EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.24 views

Schneider Electric Modicon Out-of-bounds Write (CVE-2021-22791)

A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU part numbers BMEP and BMEH, all versions, Modicon M340 CPU part...

6.5CVSS7.1AI score0.00839EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.33 views

Siemens SIMATIC S7 Uncontrolled Resource Consumption (CVE-2018-13815)

A vulnerability has been identified in SIMATIC S7-1200 All versions, SIMATIC S7-1500 All Versions V2.6. An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be abl...

7.5CVSS7AI score0.01799EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.11 views

Honeywell Controller Asset Information

It is possible to obtain attributes of the remote Honeywell Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...

5.6AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.31 views

Siemens S7-300/400 PLC (CVE-2016-9158)

A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...

7.8CVSS6.4AI score0.03027EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.26 views

Schneider Electric Modicon Path Traversal (CVE-2014-0754)

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103...

10CVSS5.5AI score0.08978EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.17 views

Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Use of Hard-Coded Credentials (CVE-2019-14930)

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin and mitsadm...

10CVSS8.4AI score0.02343EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.34 views

Siemens S7-400 CPUs Improper Input Validation (CVE-2018-16556)

A vulnerability has been identified in SIMATIC S7-400 incl. F V6 and below All versions, SIMATIC S7-400 PN/DP V7 incl. F All versions, SIMATIC S7-400H V4.5 and below All versions, SIMATIC S7-400H V6 All versions V6.0.9, SIMATIC S7-410 All versions V8.2.1. Specially crafted packets sent to port...

7.8CVSS6.9AI score0.01545EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.20 views

Rockwell Automation MicroLogix Improper Authentication (CVE-2017-12088)

An exploitable denial of service vulnerability exists in the Ethernet functionality of the Allen Bradley Micrologix 1400 Series B FRN 21.2 and below. A specially crafted packet can cause a device power cycle resulting in a fault state and deletion of ladder logic. An attacker can send one...

8.6CVSS7.2AI score0.04633EPSS
SaveExploits1References3
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.18 views

Schneider Electric Controller Asset Information

It is possible to obtain attributes of the remote Schneider Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...