292 matches found
CVE-2018-11461: Undefined Security Weakness
A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker with user privileges could use...
CVE-2018-11463: Stack-based Buffer Overflow
A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A buffer overflow in the service command...
PT-2018-2196
Name of the Vulnerable Software and Affected Versions SINUMERIK 808D V4.7 SINUMERIK 808D V4.8 SINUMERIK 828D versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl versions prior to V4.8 SP3 Description A local attacker with elevated user privileges coul...
PT-2018-2195
Name of the Vulnerable Software and Affected Versions SINUMERIK 808D V4.7 SINUMERIK 808D V4.8 SINUMERIK 828D versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl versions prior to V4.8 SP3 Description The issue is related to insufficient protection of...
PT-2018-2193
Name of the Vulnerable Software and Affected Versions SINUMERIK 828D V4.7 versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl V4.7 versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl V4.8 versions prior to V4.8 SP3 Description The issue is related to a dynamic memory overflow in the Siemens Sinumerik C...
PT-2018-2202
Name of the Vulnerable Software and Affected Versions SINUMERIK 808D V4.7 SINUMERIK 808D V4.8 SINUMERIK 828D versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl versions prior to V4.8 SP3 Description A vulnerability has been identified that could allo...
PT-2018-2201
Name of the Vulnerable Software and Affected Versions SINUMERIK 808D V4.7 SINUMERIK 808D V4.8 SINUMERIK 828D versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl versions prior to V4.8 SP3 Description A local attacker could use ioctl calls to perform o...
PT-2018-2200
Name of the Vulnerable Software and Affected Versions SINUMERIK 828D V4.7 versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl V4.7 versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl V4.8 versions prior to V4.8 SP3 Description A vulnerability has been identified that could allow a remote attacker to...
ICSA-18-345-02 Siemens SINUMERIK Controllers (Update A)
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINUMERIK Controllers Vulnerabilities: Heap-based Buffer Overflow, Integer Overflow or Wraparound, Protection Mechanism Failure, Permissions, Privileges, and Access Controls,...
PT-2018-2198
Name of the Vulnerable Software and Affected Versions SINUMERIK 808D V4.7 SINUMERIK 808D V4.8 SINUMERIK 828D versions 4.7 through 4.7 SP6 HF0 SINUMERIK 840D sl versions 4.7 through 4.7 SP6 HF4 SINUMERIK 840D sl versions 4.8 through 4.8 SP2 Description The issue is related to permission management...
PT-2018-2197
Name of the Vulnerable Software and Affected Versions SINUMERIK 808D V4.7 SINUMERIK 808D V4.8 SINUMERIK 828D versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl versions prior to V4.8 SP3 Description A local attacker with user privileges could exploit...
PT-2018-2194
Name of the Vulnerable Software and Affected Versions SINUMERIK 828D V4.7 versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl V4.7 versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl V4.8 versions prior to V4.8 SP3 Description The issue is related to an integer overflow in the VNC server of the affecte...
PT-2018-2199
Name of the Vulnerable Software and Affected Versions SINUMERIK 808D V4.7 SINUMERIK 808D V4.8 SINUMERIK 828D versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl versions prior to V4.8 SP3 Description The issue is related to a buffer overflow in the...
Siemens OpenSSL Vulnerability in Industrial Products (Update E)
1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION : Exploitable remotely Vendor : Siemens Equipment : Industrial Products Vulnerability : Cleartext Transmission of Sensitive Information 2. UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-18-226-02 Siemens...
Siemens SIMATIC, SINUMERIK, and PROFINET IO (Update D)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
ICSA-18-060-01_Siemens SIMATIC, SIMOTION, and SINUMERIK (Update A)
1. EXECUTIVE SUMMARY CVSS v3 8.2 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-18-060-01 Siemens SIMATIC, SIMOTION, and SINUMERIK that was published March 01, 2018, on the NCCIC/ICS-CERT website. 3. RISK EVALUATION Successful exploitation of...
Siemens Industrial Products (Update D)
CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: Industrial products Vulnerability: Improper Input Validation UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-17-339-01C Siemens Industrial Products that w...
Siemens Industrial Products (Update B)
CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: Industrial products Vulnerability: Improper Input Validation UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-17-339-01A Siemens Industrial Products that w...
ICSA-17-180-01A_Siemens SIMATIC Industrial PCs, SINUMERIK Panel Control Unit, and SIMOTION P320 (Update A)
CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIMATIC Industrial PCs, SINUMERIK Panel Control Unit PCU, SIMOTION P320 Vulnerability: Permissions, Privileges, and Access Controls UPDATED INFORMATION This updated advisory is a follow-up to the...
CVE-2017-6865
CVE-2017-6865 is a DoS vulnerability in Siemens PROFINET DCP handling affecting multiple Siemens products (WinCC, STEP 7/TIA Portal, PCS 7, WinAC/WinCC flexible, SCT, SINEMA, SINUMERIK, etc.). The root cause is improper input validation, where specially crafted PROFINET DCP broadcast packets on a...