Lucene search
+L

292 matches found

Cvelist
Cvelist
•added 2018/12/12 4:00 p.m.•34 views

CVE-2018-11458

A vulnerability has been identified in SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code...

7.9AI score0.04593EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2018/12/12 4:00 p.m.•30 views

CVE-2018-11461

A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker with user privileges could use...

6.5AI score0.00354EPSS
SaveExploits0References2
CVE
CVE
•added 2018/12/12 4:00 p.m.•77 views

CVE-2018-11462

Siemens SINUMERIK controllers (808D v4.7/v4.8, 828D v4.7, 840D sl v4.7/v4.8) are affected by CVE-2018-11462. A remote attacker could send a specially crafted authentication request to escalate privileges to an elevated user account (not root) with network access and no user interaction. Impact co...

9.8CVSS9.1AI score0.03687EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2018/12/12 4:00 p.m.•34 views

CVE-2018-11457

A vulnerability has been identified in SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code...

7.9AI score0.04593EPSS
SaveExploits0References2
CVE
CVE
•added 2018/12/12 4:00 p.m.•73 views

CVE-2018-11461

Siemens SINUMERIK controllers (808D v4.7/v4.8, 828D v4.7 <SP6 HF1, 840D sl v4.7 <SP6 HF5, 840D sl v4.8

6.6CVSS6.5AI score0.00354EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2018/12/12 4:00 p.m.•27 views

CVE-2018-11462

A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. By sending a specially crafted authentication...

9.2AI score0.03687EPSS
SaveExploits0References2
CVE
CVE
•added 2018/12/12 4:00 p.m.•72 views

CVE-2018-11458

The CVE-2018-11458 issue affects Siemens SINUMERIK controllers (e.g., 828D v4.7, 840D sl v4.7/v4.8) where the integrated VNC server on port 5900/TCP can be exploited remotely to execute code with privileged permissions. Exploitation requires network access and is possible without user interaction...

9.3CVSS7.8AI score0.04593EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2018/12/12 4:00 p.m.•31 views

CVE-2018-11460

A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker with elevated user privileges...

7.3AI score0.00378EPSS
SaveExploits0References2
CVE
CVE
•added 2018/12/12 4:00 p.m.•83 views

CVE-2018-11459

Siemens SINUMERIK controllers are affected: SINUMERIK 808D v4.7/all versions and v4.8, SINUMERIK 828D v4.7, and SINUMERIK 840D sl v4.7/v4.8 (specific sub-versions). Root cause: attacker-modifiable, user-writeable configuration files can be reloaded after reboot or manual start, causing attacker-c...

7.8CVSS7.3AI score0.00378EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2018/12/12 4:00 p.m.•30 views

CVE-2018-11463

A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A buffer overflow in the service command...

7.7AI score0.00464EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2018/12/12 4:00 p.m.•39 views

CVE-2018-11464

A vulnerability has been identified in SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a...

4.2AI score0.01857EPSS
SaveExploits0References2
CVE
CVE
•added 2018/12/12 4:00 p.m.•66 views

CVE-2018-11464

Siemens SINUMERIK controllers are affected by CVE-2018-11464 due to an issue in the integrated VNC server on port 5900/TCP, which could allow a remote attacker to cause a denial-of-service of the VNC service. The vulnerability applies to SINUMERIK 828D v4.7 (pre-SP6 HF1), SINUMERIK 840D sl v4.7 (...

4.3CVSS4.3AI score0.01857EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/12 12:00 a.m.•4 views

CVE-2018-11459: Protection Mechanism Failure

A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker could modify a user-writeable...

7.8CVSS5.8AI score0.00378EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/12 12:00 a.m.•8 views

CVE-2018-11462: Undefined Security Weakness

A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. By sending a specially crafted authentication...

9.8CVSS5.9AI score0.03687EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/12 12:00 a.m.•5 views

CVE-2018-11466: Uncaught Exception

A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. Specially crafted network packets sent to port...

9.8CVSS6.1AI score0.04003EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/12 12:00 a.m.•6 views

CVE-2018-11465: Uncaught Exception

A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker could use ioctl calls to do ou...

7.8CVSS6AI score0.00433EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/12 12:00 a.m.•5 views

CVE-2018-11458: Integer Overflow or Wraparound

A vulnerability has been identified in SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code...

9.3CVSS6.2AI score0.04593EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/12 12:00 a.m.•6 views

CVE-2018-11457: Heap-based Buffer Overflow

A vulnerability has been identified in SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code...

9.3CVSS6.2AI score0.04593EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/12 12:00 a.m.•6 views

CVE-2018-11460: Protection Mechanism Failure

A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker with elevated user privileges...

7.8CVSS5.8AI score0.00378EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/12 12:00 a.m.•6 views

CVE-2018-11464: Uncaught Exception

A vulnerability has been identified in SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a...

4.3CVSS5.8AI score0.01857EPSS
SaveExploits0References2
Rows per page
Query Builder