259 matches found
CVE-2018-11466
A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. Specially crafted network packets sent to port...
CVE-2018-11460
SiemenS CVE-2018-11460 affects SINUMERIK CNC controllers (808D, 828D, 840D sl) where a local attacker with elevated privileges can modify a CRAMFS archive to cause the system to load a tampered CRAMFS after reboot, executing attacker-controlled code with root privileges. Affected versions include...
CVE-2018-11466
Siemens SINUMERIK controllers are affected by CVE-2018-11466. A remote attacker with network access to port 102/tcp (ISO-TSAP) could cause a Denial-of-Service or execute code in the context of the integrated software firewall. Affected products include SINUMERIK 808D v4.7/v4.8, SINUMERIK 828D v4....
CVE-2018-11465
A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker could use ioctl calls to do ou...
CVE-2018-11459
A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker could modify a user-writeable...
CVE-2018-11465
Siemens SINUMERIK controllers (808D, 828D, 840D sl) running affected V4.x are vulnerable to CVE-2018-11465 via ioctl abuse that can cause out-of-bounds reads, arbitrary writes, or kernel-mode code execution. Affected: 808D v4.7/v4.8 (all before certain SPs), 828D v4.7 (all before v4.7 SP6 HF1), 8...
CVE-2018-11462
Siemens SINUMERIK controllers (808D v4.7/v4.8, 828D v4.7, 840D sl v4.7/v4.8) are affected by CVE-2018-11462. A remote attacker could send a specially crafted authentication request to escalate privileges to an elevated user account (not root) with network access and no user interaction. Impact co...
CVE-2018-11461
A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker with user privileges could use...
CVE-2018-11458
A vulnerability has been identified in SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code...
CVE-2018-11463
CVE-2018-11463 affects SINUMERIK 808D (v4.7/v4.8), SINUMERIK 828D (v4.7 before SP6 HF1), and SINUMERIK 840D sl (v4.7 before SP6 HF5, v4.8 before SP3). The issue is a stack-based buffer overflow in the service command application, enabling a local attacker with existing user privileges to execute ...
CVE-2018-11457
A vulnerability has been identified in SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code...
CVE-2018-11457
Siemens SINUMERIK controllers (828D v4.7, 840D sl v4.7/v4.8) expose an unpatched remote code execution flaw in the integrated web server on port 4842/TCP. An attacker with network access and without privileges can send specially crafted requests to this port to execute code with system privileges...
CVE-2018-11459
Siemens SINUMERIK controllers are affected: SINUMERIK 808D v4.7/all versions and v4.8, SINUMERIK 828D v4.7, and SINUMERIK 840D sl v4.7/v4.8 (specific sub-versions). Root cause: attacker-modifiable, user-writeable configuration files can be reloaded after reboot or manual start, causing attacker-c...
CVE-2018-11461
Siemens SINUMERIK controllers (808D v4.7/v4.8, 828D v4.7 <SP6 HF1, 840D sl v4.7 <SP6 HF5, 840D sl v4.8
CVE-2018-11464
A vulnerability has been identified in SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a...
CVE-2018-11460
A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A local attacker with elevated user privileges...
CVE-2018-11463
A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. A buffer overflow in the service command...
CVE-2018-11462
A vulnerability has been identified in SINUMERIK 808D V4.7 All versions, SINUMERIK 808D V4.8 All versions, SINUMERIK 828D V4.7 All versions V4.7 SP6 HF1, SINUMERIK 840D sl V4.7 All versions V4.7 SP6 HF5, SINUMERIK 840D sl V4.8 All versions V4.8 SP3. By sending a specially crafted authentication...
CVE-2018-11458
The CVE-2018-11458 issue affects Siemens SINUMERIK controllers (e.g., 828D v4.7, 840D sl v4.7/v4.8) where the integrated VNC server on port 5900/TCP can be exploited remotely to execute code with privileged permissions. Exploitation requires network access and is possible without user interaction...
CVE-2018-11464
Siemens SINUMERIK controllers are affected by CVE-2018-11464 due to an issue in the integrated VNC server on port 5900/TCP, which could allow a remote attacker to cause a denial-of-service of the VNC service. The vulnerability applies to SINUMERIK 828D v4.7 (pre-SP6 HF1), SINUMERIK 840D sl v4.7 (...