CVE-2021-25661

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.6AI score0.01148EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2021/05/12 1:18 p.m.•49 views

CVE-2021-25662

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.6AI score0.0164EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2021/05/12 1:18 p.m.•38 views

CVE-2021-27383

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.6AI score0.01792EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2021/05/12 1:18 p.m.•40 views

CVE-2020-25242

A vulnerability has been identified in SIMATIC NET CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Standard incl. SIPLUS variants All versions. Specially crafted packets sent to TCP port 102 could cause a...

7.4AI score0.01269EPSS
SaveExploits0References2
CVE
CVE
•added 2021/05/12 1:18 p.m.•111 views

CVE-2021-27383

CVE-2021-27383 describes a heap allocation leak vulnerability in the SmartVNC server Tight encoder, causing a Denial-of-Service condition. Affected are Siemens SmartVNC deployments on various HMI/WinCC panels (e.g., SIMATIC HMI Comfort Outdoor Panels, Comfort Panels, KTP Mobile Panels, WinCC Runt...

7.5CVSS7.3AI score0.01792EPSS
SaveExploits0References3Affected Software1
CVE
CVE
•added 2021/05/12 1:18 p.m.•91 views

CVE-2021-25661

CVE-2021-25661 is an out-of-bounds memory access vulnerability in SmartVNC that can be triggered on the client side when data is sent from the server, potentially causing a Denial-of-Service. Affected products include SIMATIC WinCC Runtime Advanced and related HMI/SU panels (Outdoor Panels v15/v1...

7.5CVSS7.3AI score0.01148EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
•added 2021/05/12 1:18 p.m.•12 views

CVE-2021-25661

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7AI score0.01148EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
•added 2021/05/12 1:18 p.m.•11 views

CVE-2021-25660

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7AI score0.00969EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2021/05/12 1:18 p.m.•14 views

CVE-2021-25662

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.1AI score0.0164EPSS
SaveExploits0References2
CVE
CVE
•added 2021/05/12 1:18 p.m.•86 views

CVE-2020-25242

CVE-2020-25242 affects Siemens SIMATIC NET CP 343-1 devices (Advanced/Lean/Standard, including SIPLUS variants) across all versions. The vulnerability is an Uncontrolled Resource Consumption issue triggered by specially crafted packets sent to TCP port 102, allowing a remote DoS that may require ...

7.8CVSS7.4AI score0.01269EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2021/05/12 1:18 p.m.•43 views

CVE-2021-27384

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

9.7AI score0.02559EPSS
SaveExploits0References3
CVE
CVE
•added 2021/05/12 1:18 p.m.•103 views

CVE-2021-25660

The CVE-2021-25660 entry maps to Siemens SmartVNC/WinCC/HMI components with an out-of-bounds memory access vulnerability that can trigger a Denial-of-Service on the server side (and related variants on the client side). Affected products include SIMATIC HMI Comfort Outdoor Panels (various V15/V16...

7.5CVSS7.3AI score0.00969EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2021/05/12 1:18 p.m.•42 views

CVE-2021-25660

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.6AI score0.00969EPSS
SaveExploits0References1
CVE
CVE
•added 2021/05/12 1:18 p.m.•69 views

CVE-2019-19276

CVE-2019-19276 affects Siemens SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS) and SIMATIC HMI KTP Mobile Panels, all versions prior to version 16 update 4. The root cause is an out-of-bounds write (CWE-787) triggered by specially crafted UDP packets to port 161, causing the SNMP service...

5.3CVSS5.2AI score0.0102EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2021/05/12 1:18 p.m.•51 views

CVE-2019-19276

A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI KTP Mobile Panels All versions V16 Update 4. Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manu...

5.2AI score0.0102EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•7 views

CVE-2021-27385: Uncontrolled Resource Consumption

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.5CVSS5.7AI score0.02555EPSS
SaveExploits0References9
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•9 views

CVE-2019-19276: Out-of-bounds Write

A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI KTP Mobile Panels All versions V16 Update 4. Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manu...

5.3CVSS5.6AI score0.0102EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2021/05/12 12:00 a.m.•8 views

PT-2021-9018

Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Panels 1st Generation incl. SIPLUS variants versions prior to V16 Update 4 SIMATIC HMI KTP Mobile Panels versions prior to V16 Update 4 Description A vulnerability has been identified that can cause the SNMP service of...

5.3CVSS0.0102EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2021/05/12 12:00 a.m.•3 views

PT-2021-11122

Name of the Vulnerable Software and Affected Versions: SIMATIC NET CP 343-1 Advanced incl. SIPLUS variants All versions SIMATIC NET CP 343-1 Lean incl. SIPLUS variants All versions SIMATIC NET CP 343-1 Standard incl. SIPLUS variants All versions Description: A Denial-of-Service condition can be...

7.8CVSS0.01269EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•9 views

CVE-2021-25662: Improper Handling of Exceptional Conditions

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.5CVSS5.7AI score0.0164EPSS
SaveExploits0References6
Rows per page
Query Builder