CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:N/I:N/A:P
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
AI Score
Confidence
High
EPSS
Percentile
39.5%
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.
Vendor | Product | Version | CPE |
---|---|---|---|
siemens | simatic_hmi_ktp_mobile_panels_firmware | 16 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:-:*:*:*:*:*:* |
siemens | simatic_hmi_ktp_mobile_panels_firmware | 16 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_2:*:*:*:*:*:* |
siemens | simatic_hmi_ktp_mobile_panels_firmware | 16 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_3:*:*:*:*:*:* |
siemens | simatic_hmi_ktp_mobile_panels | - | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:* |
siemens | simatic_hmi_comfort_panels_firmware | 16 | cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:-:*:*:*:*:*:* |
siemens | simatic_hmi_comfort_panels_firmware | 16 | cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_2:*:*:*:*:*:* |
siemens | simatic_hmi_comfort_panels_firmware | 16 | cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_3:*:*:*:*:*:* |
siemens | simatic_hmi_comfort_panels | - | cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:* |
[
{
"product": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions < V16 Update 4"
}
]
},
{
"product": "SIMATIC HMI KTP Mobile Panels",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions < V16 Update 4"
}
]
}
]
More
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:N/I:N/A:P
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
AI Score
Confidence
High
EPSS
Percentile
39.5%