Lucene search
+L

2326 matches found

Positive Technologies
Positive Technologies
•added 2014/03/16 12:00 a.m.•2 views

PT-2014-4585

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1500 CPU PLC devices versions prior to 1.5.0 Description The issue concerns the random-number generator, which lacks sufficient entropy. This weakness can be exploited by remote attackers to bypass cryptographic protection...

8.3CVSS0.02744EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2014/03/16 12:00 a.m.•3 views

PT-2014-4587

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1500 CPU PLC devices versions prior to 1.5.0 Description The issue allows remote attackers to cause a denial of service, resulting in a defect-mode transition, by sending crafted HTTP packets. Recommendations For versions...

7.8CVSS0.04456EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2014/03/16 12:00 a.m.•5 views

PT-2014-4583

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1500 CPU PLC devices versions prior to 1.5.0 Description The issue allows remote attackers to inject headers via unspecified vectors, potentially affecting the integrated web server on the devices. Recommendations For versio...

5.8CVSS0.02417EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2014/03/16 12:00 a.m.•3 views

PT-2014-4582

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1500 CPU PLC devices versions prior to 1.5.0 Description A cross-site scripting XSS issue exists in the integrated web server, allowing remote attackers to inject arbitrary web script or HTML. This could potentially lead to...

4.3CVSS0.02168EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2014/03/16 12:00 a.m.•3 views

PT-2014-4586

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1500 CPU PLC devices versions prior to 1.5.0 Description The issue allows remote attackers to cause a denial of service, resulting in a defect-mode transition, by sending crafted Profinet packets. Recommendations For version...

6.1CVSS0.0101EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2014/03/16 12:00 a.m.•3 views

PT-2014-4589

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1500 CPU PLC devices versions prior to 1.5.0 Description The issue allows remote attackers to cause a denial of service, resulting in a defect-mode transition, by sending crafted HTTPS packets. Recommendations For versions...

7.8CVSS0.04456EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2014/03/16 12:00 a.m.•4 views

PT-2014-4584

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1500 CPU PLC devices versions prior to 1.5.0 Description The issue concerns an open redirect vulnerability in the integrated web server. This vulnerability allows remote attackers to redirect users to arbitrary web sites,...

4.3CVSS0.02204EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2014/03/16 12:00 a.m.•6 views

PT-2014-1955

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1500 CPU PLC devices versions prior to 1.5.0 Siemens SIMATIC S7-1200 CPU PLC devices versions prior to 4.0 Description A cross-site request forgery CSRF issue affects the software, allowing remote attackers to hijack the...

5.8CVSS0.01344EPSS
SaveExploits1References9
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/03/16 12:00 a.m.•6 views

CVE-2014-2249: Cross-Site Request Forgery (CSRF)

Cross-site request forgery CSRF vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors...

5.8CVSS5.9AI score0.01344EPSS
SaveExploits1References2
ICS
ICS
•added 2014/01/25 7:00 a.m.•71 views

Siemens SIMATIC S7-1200 CPU Web Vulnerabilities

OVERVIEW Siemens ProductCERT and Ralf Spenneberg, Hendrik Schwartke, and Maik Brüggemann from OpenSource Training have reported two vulnerabilities in the Siemens SIMATIC S7-1200 CPU family. Siemens has produced a new product release that mitigates these vulnerabilities. AFFECTED PRODUCTS The...

5.8CVSS6.1AI score0.20862EPSS
SaveExploits4References10
CNVD
CNVD
•added 2014/01/23 12:00 a.m.•35 views

Siemens S7 1214C PN-DCP Request Message Buffer Overflow Vulnerability

The SIMATIC S7-1200 is a small controller module used in low-end discrete automation systems and stand-alone automation. hardware CPU 1214C under the Siemens S7-1200 family supports the Data Link Layer Device Management Protocol PN-DCP PROFINET Discovery and Configuration Protocol for local area...

1.9AI score
SaveExploits0
ICS
ICS
•added 2014/01/16 7:00 a.m.•228 views

Siemens Industrial Products OpenSSL Heartbleed Vulnerability (Update B)

OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-14-105-03A Siemens Industrial Products OpenSSL Heartbleed Vulnerability that was published April 29, 2014, on the NCCIC/ICS-CERT web site. Siemens reported to ICS-CERT a list of products affected by the OpenSSL...

7.5CVSS6.7AI score0.99999EPSS
SaveExploits96References10
Kitploit
Kitploit
•added 2014/01/08 7:00 a.m.•44 views

[THC-Hydra v7.6] Fast Parallel Network Logon Cracker

Hydra is a parallelized network logon cracker which supports numerous protocols to attack, new modules are easy to add, beside that, it is flexible and very fast. Features IPv6 Support Graphic User Interface Internationalized support RFC 4013 HTTP proxy support SOCKS proxy support The tool suppor...

7.5AI score
SaveExploits0
Positive Technologies
Positive Technologies
•added 2013/08/05 12:00 a.m.•20 views

PT-2013-87: Insuffient Entropy in Siemens SIMATIC S7-1200 CPU PLC

The specialists of the Positive Research center have detected an Insuffient Entropy vulnerability in Siemens SIMATIC S7-1200 CPU PLC. Due to low entropy in its random number generator, the integrated web server’s authentication method port 80/tcp and port 443/tcp could allow attackers to hijack w...

8.3CVSS6.8AI score0.03144EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
•added 2013/08/05 12:00 a.m.•28 views

PT-2013-84: Insuffient Entropy in Siemens SIMATIC S7-1500 CPU PLC

The specialists of the Positive Research center have detected an Insuffient Entropy vulnerability in Siemens SIMATIC S7-1500 CPU PLC. Due to low entropy in its random number generator, the authentication of the integrated web server port 80/tcp and port 443/tcp of S7-1500 PLCs might allow attacke...

8.3CVSS6.7AI score0.02744EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2013/08/05 12:00 a.m.•27 views

PT-2013-82: Cross-Site Scripting in Siemens SIMATIC S7-1500 CPU PLC

The specialists of the Positive Research center have detected a Cross-Site Scripting vulnerability in Siemens SIMATIC S7-1500 CPU PLC. The integrated web server port 80/tcp and port 443/tcp of the affected device might be vulnerable to Cross-Site Scripting XSS attacks. How to fix Update your...

4.3CVSS5.8AI score0.02168EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2013/08/05 12:00 a.m.•26 views

PT-2013-83: Arbitrary HTML Injection in Siemens SIMATIC S7-1500 CPU PLC

The specialists of the Positive Research center have detected an Arbitrary HTML Injection vulnerability in Siemens SIMATIC S7-1500 CPU PLC. The integrated web server port 80/tcp and port 443/tcp of the affected device might allow attackers to inject HTML headers. How to fix Update your firmware u...

5.8CVSS6.8AI score0.02417EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2013/08/05 12:00 a.m.•29 views

PT-2013-85: Open Redirect in Siemens SIMATIC S7-1500 CPU PLC

The specialists of the Positive Research center have detected an Open Redirect vulnerability in Siemens SIMATIC S7-1500 CPU PLC. The integrated web server port 80/tcp and port 443/tcp of the affected device might allow attackers to redirect users to untrusted websites. How to fix Update your...

4.3CVSS6.6AI score0.02204EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2013/08/05 12:00 a.m.•27 views

PT-2013-81: Cross-Site Request Forgery in Siemens SIMATIC S7-1500 CPU PLC

The specialists of the Positive Research center have detected a Cross-Site Request Forgery vulnerability in Siemens SIMATIC S7-1500 CPU PLC. The web server of the affected PLCs port 80/tcp and port 443/tcp might allow CSRF Cross-Site Request Forgery attacks, compromising integrity and availabilit...

5.8CVSS6.8AI score0.01344EPSS
SaveExploits1References7
OpenVAS
OpenVAS
•added 2013/04/25 12:00 a.m.•47 views

Siemens SIMATIC S7-1200 Multiple DoS Vulnerabilities (SSA-724606)

Siemens SIMATIC S7-1200 devices are prone to multiple denial of service DoS vulnerabilities. SPDX-FileCopyrightText: 2013 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only CP...

7.8CVSS7.2AI score0.02392EPSS
SaveExploits1References3
Rows per page
Query Builder