Siemens SIMATIC S7-1200 Multiple DoS Vulnerabilities (SSA-724606). Prone to denial of service (DoS) vulnerabilities. Update to version 4.0.0 or later
Reporter | Title | Published | Views | Family All 13 |
---|---|---|---|---|
![]() | Siemens SIMATIC S7-1200 Improper Input Validation Vulnerabilities | 6 Sep 201812:00 | – | ics |
![]() | Siemens SIMATIC S7-1200 CPU Family Denial of Service (CVE-2013-0700) | 7 Feb 202200:00 | – | nessus |
![]() | Siemens Simatic Improper Restriction of Operations within the Bounds of a Memory Buffer | 8 Nov 201900:00 | – | nessus |
![]() | Siemens Simatic Improper Restriction of Operations within the Bounds of a Memory Buffer | 8 Nov 201900:00 | – | nessus |
![]() | Siemens SIMATIC S7-1200 CPU Family Denial of Service (CVE-2013-2780) | 7 Feb 202200:00 | – | nessus |
![]() | CVE-2013-0700 | 22 Apr 201301:00 | – | cvelist |
![]() | CVE-2013-2780 | 22 Apr 201301:00 | – | cvelist |
![]() | CVE-2013-0700 | 22 Apr 201303:27 | – | nvd |
![]() | CVE-2013-2780 | 22 Apr 201303:27 | – | nvd |
![]() | CVE-2013-0700 | 22 Apr 201303:27 | – | cve |
Source | Link |
---|---|
securityfocus | www.securityfocus.com/bid/57023 |
securityfocus | www.securityfocus.com/bid/59399 |
cert-portal | www.cert-portal.siemens.com/productcert/html/ssa-724606.html |
# SPDX-FileCopyrightText: 2013 Greenbone AG
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-only
CPE = "cpe:/a:siemens:simatic_s7_1200";
if (description)
{
script_oid("1.3.6.1.4.1.25623.1.0.803387");
script_version("2025-04-22T10:32:18+0000");
script_cve_id("CVE-2013-0700", "CVE-2013-2780");
script_tag(name:"cvss_base", value:"7.8");
script_tag(name:"cvss_base_vector", value:"AV:N/AC:L/Au:N/C:N/I:N/A:C");
script_tag(name:"last_modification", value:"2025-04-22 10:32:18 +0000 (Tue, 22 Apr 2025)");
script_tag(name:"creation_date", value:"2013-04-25 16:01:27 +0530 (Thu, 25 Apr 2013)");
script_name("Siemens SIMATIC S7-1200 Multiple DoS Vulnerabilities (SSA-724606)");
script_category(ACT_GATHER_INFO);
script_copyright("Copyright (C) 2013 Greenbone AG");
script_family("Denial of Service");
script_dependencies("gb_siemens_simatic_s7_consolidation.nasl");
script_mandatory_keys("siemens/simatic_s7/detected");
script_xref(name:"URL", value:"https://cert-portal.siemens.com/productcert/html/ssa-724606.html");
script_xref(name:"URL", value:"http://www.securityfocus.com/bid/57023");
script_xref(name:"URL", value:"http://www.securityfocus.com/bid/59399");
script_tag(name:"summary", value:"Siemens SIMATIC S7-1200 devices are prone to multiple denial of
service (DoS) vulnerabilities.");
script_tag(name:"vuldetect", value:"Checks if a vulnerable version is present on the target host.");
script_tag(name:"impact", value:"Successful exploitation will allow attackers to cause DoS
conditions via specially-crafted packets to TCP port 102 or UCP port 161.");
script_tag(name:"affected", value:"Siemens SIMATIC S7-1200 versions 2.x and 3.x.");
script_tag(name:"solution", value:"Update to version 4.0.0 or later.");
script_tag(name:"qod_type", value:"remote_banner");
script_tag(name:"solution_type", value:"VendorFix");
exit(0);
}
include("host_details.inc");
include("version_func.inc");
if(!version = get_app_version(cpe: CPE, nofork: TRUE))
exit(0);
if(version =~ "^[23]\.") {
report = report_fixed_ver(installed_version: version, fixed_version: "4.0.0");
security_message(port: 0, data: report);
exit(0);
}
exit(99);